Optimization and Performance Evaluation of a Transducer for Bone Conduction Implants

We designed and implemented an electromagnetic transducer for implantable bone conduction hearing aids. The proposed transducer is smaller than previous bone conduction transducers for easy implantation and was designed using high permeability metals to produce large electromagnetic forces. In addition, the number of cantilever beams was changed from two to three to minimize distortion of the transducer, potentially due to twisting of the cantilever beam. The proposed transducer consists of a titanium cover with three screw holes, a metal ring, a circular plate, a vibrational membrane with a three-cantilever structure, a metal plate and cylinder, a permanent magnet, top and bottom coils, and a cylindrical titanium case. The transducer was optimally designed based on analysis of electromagnetic and mechanical vibrations, and the target resonance frequency was derived by controlling the variable elements of the vibrational membrane. The transducer was manufactured based on the results of finite element analysis, and the validity of the design was verified by comparing the results of vibration measurement experiments and a simulation. Finally, to evaluate the performance of the proposed transducer, the transducer was attached to the mastoid of participants and functional near-infrared spectroscopy was used to measure brain activation changes of the auditory cortex due to vibration stimulation.

[1]  V. Shklovsky,et al.  Speech and Non-Speech Sound Categorization in Auditory Cortex: fMRI Correlates , 2019, Human Physiology.

[2]  Jin-Ho Cho,et al.  Design of a dual-coil type electromagnetic actuator for implantable bone conduction hearing devices , 2019, Technology and health care : official journal of the European Society for Engineering and Medicine.

[3]  A J Maniglia,et al.  The history and development of the implantable hearing aid. , 1995, Otolaryngologic clinics of North America.

[4]  Heather Bortfeld,et al.  Functional near-infrared spectroscopy as a tool for assessing speech and spoken language processing in pediatric and adult cochlear implant users. , 2018, Developmental psychobiology.

[5]  Fan-Gang Zeng,et al.  Design, Fabrication, and Evaluation of a Parylene Thin-Film Electrode Array for Cochlear Implants , 2019, IEEE Transactions on Biomedical Engineering.

[6]  K. K. Tan,et al.  The spatial location of EEG electrodes: locating the best-fitting sphere relative to cortical anatomy. , 1993, Electroencephalography and clinical neurophysiology.

[7]  Stephan Paul,et al.  A technical review and evaluation of implantable sensors for hearing devices , 2018, Biomedical engineering online.

[8]  Ann-Christine Ehlis,et al.  Variability of (functional) hemodynamics as measured with simultaneous fNIRS and fMRI during intertemporal choice , 2013, NeuroImage.

[9]  Martin Walter,et al.  Auditory Deficits in Audiovisual Speech Perception in Adult Asperger’s Syndrome: fMRI Study , 2019, Front. Psychol..

[10]  Robert M Rhodes,et al.  Future of Implantable Auditory Devices. , 2019, Otolaryngologic clinics of North America.

[11]  Marc M. van Wanrooij,et al.  Measuring Cortical Activity During Auditory Processing with Functional Near-Infrared Spectroscopy , 2018, Journal of hearing science.

[12]  Jin-Ho Cho,et al.  A tri-coil bellows-type round window transducer with improved frequency characteristics for middle-ear implants , 2016, Hearing Research.

[13]  C. Röösli,et al.  The Bonebridge: Preclinical evaluation of a new transcutaneously-activated bone anchored hearing device , 2013, Hearing Research.

[14]  Martin Koch,et al.  Sensor-actuator component for a Floating Mass Transducer-based fully implantable hearing aid , 2019, Hearing Research.

[15]  Sungho Tak,et al.  Wavelet minimum description length detrending for near-infrared spectroscopy. , 2009, Journal of biomedical optics.

[16]  Thomas Lenarz,et al.  fNIRS for future use in auditory diagnostics , 2016 .

[17]  Jill B Firszt,et al.  Cochlear Implantation in Adults With Asymmetric Hearing Loss , 2012, Ear and hearing.

[18]  Harold H. Kim,et al.  Hearing Aids: A Review of What's New , 2006, Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery.

[19]  Sabine Reinfeldt,et al.  A Novel Bone Conduction Implant - Analog Radio Frequency Data and Power Link Design , 2012 .

[20]  Jin-Ho Cho,et al.  Design and Development of a Tri-Coil Bellows Transducer for RW-Drive Implantable Middle-Ear Hearing Aid Using FEA , 2018, IEEE/ASME Transactions on Mechatronics.

[21]  Roberto Albera,et al.  A new bone conduction hearing aid to predict hearing outcome with an active implanted device , 2019, European Archives of Oto-Rhino-Laryngology.

[22]  Elisa Gil-Carcedo,et al.  Active middle ear implants. , 2019, Acta otorrinolaringologica espanola.

[23]  Martin Leinung,et al.  A new adhesive bone conduction hearing system as a treatment option for transient hearing loss after middle ear surgery , 2019, European Archives of Oto-Rhino-Laryngology.

[24]  Sigfrid D. Soli,et al.  Treatment of mixed hearing losses via implantation of a vibratory transducer on the round window , 2006, International journal of audiology.

[25]  Stefan Stenfelt,et al.  A novel bone conduction implant (BCI): Engineering aspects and pre-clinical studies , 2010, International journal of audiology.

[26]  Eric Truy,et al.  Benefit of the Vibrant Soundbridge Device in Patients Implanted For 5 to 8 Years , 2008, Ear and hearing.

[27]  Samantha C Harrison,et al.  Shedding Light On The Human Auditory Cortex: A Review Of The Advances In Near Infrared Spectroscopy (NIRS) , 2019, Reports in Medical Imaging.

[28]  J. Lee,et al.  Benefits of active middle ear implants in mixed hearing loss: Stapes versus round window , 2017, The Laryngoscope.

[29]  George B. Wanna,et al.  Middle Ear Implantable Hearing Devices: An Overview , 2009, Trends in amplification.

[30]  Marc Moonen,et al.  Measurement and Analysis of Feedback and Nonlinearities for the Codacs Direct Acoustic Cochlear Implant , 2017, IEEE Access.

[31]  Xiao-Su Hu,et al.  Human central auditory plasticity: A review of functional near‐infrared spectroscopy (fNIRS) to measure cochlear implant performance and tinnitus perception , 2018, Laryngoscope investigative otolaryngology.

[32]  Sungho Tak,et al.  NIRS-SPM: Statistical parametric mapping for near-infrared spectroscopy , 2009, NeuroImage.

[33]  Sabine Reinfeldt,et al.  New developments in bone-conduction hearing implants: a review , 2015, Medical devices.

[34]  G. Sprinzl,et al.  Active transcutaneous bone conduction hearing implants: Systematic review and meta-analysis , 2019, PloS one.

[35]  A Mudry,et al.  History of the technological development of air conduction hearing aids , 2000, The Journal of Laryngology & Otology.

[36]  Mario A Svirsky,et al.  Auditory cortical plasticity in cochlear implant users , 2019, Current Opinion in Neurobiology.