Occupational radiation doses to the extremities and the eyes in interventional radiology and cardiology procedures.

OBJECTIVES The aim of this study was to determine occupational dose levels in interventional radiology and cardiology procedures. METHODS The study covered a sample of 25 procedures and monitored occupational dose for all laboratory personnel. Each individual wore eight thermoluminescent dosemeters next to the eyes, wrists, fingers and legs during each procedure. Radiation protection shields used in each procedure were recorded. RESULTS The highest doses per procedure were recorded for interventionists at the left wrist (average 485 μSv, maximum 5239 μSv) and left finger (average 324 μSv, maximum 2877 μSv), whereas lower doses were recorded for the legs (average 124 μSv, maximum 1959 μSv) and the eyes (average 64 μSv, maximum 1129 μSv). Doses to the assisting nurses during the intervention were considerably lower; the highest doses were recorded at the wrists (average 26 μSv, maximum 41 μSv) and legs (average 18 μSv, maximum 22 μSv), whereas doses to the eyes were minimal (average 4 μSv, maximum 16 μSv). Occupational doses normalised to kerma area product (KAP) ranged from 11.9 to 117.3 μSv/1000 cGy cm² and KAP was poorly correlated to the interventionists' extremity doses. CONCLUSION Calculation of the dose burden for interventionists considering the actual number of procedures performed annually revealed that dose limits for the extremities and the lenses of the eyes were not exceeded. However, there are cases in which high doses have been recorded and this can lead to exceeding the dose limits when bad practices are followed and the radiation protection tools are not properly used.

[1]  William Grossman,et al.  Cardiac Catheterization, Angiography, and Intervention , 1990 .

[2]  J. Damilakis,et al.  Radiation exposure to the hands of operators during angiographic procedures. , 1995, European journal of radiology.

[3]  J H Ellis,et al.  Radiation protection of the hand in interventional radiology: should it fit like a glove? , 1996, Radiology.

[4]  J R Williams,et al.  The interdependence of staff and patient doses in interventional radiology. , 1997, The British journal of radiology.

[5]  L. S. Schultze Kool,et al.  Patient and staff radiation dose in fluoroscopy-guided TIPS procedures and dose reduction, using dedicated fluoroscopy exposure settings. , 1998, The British journal of radiology.

[6]  J. Williams,et al.  Radiation exposure to medical staff in interventional radiology. , 1998, The British journal of radiology.

[7]  E Vañó,et al.  Radiation exposure to medical staff in interventional and cardiac radiology. , 1998, The British journal of radiology.

[8]  J. Kaufman,et al.  Cost comparison of radiologic versus surgical placement of long-term hemodialysis catheters. , 1999, AJR. American journal of roentgenology.

[9]  J. Karppinen,et al.  The dose-area product and assessment of the occupational dose in interventional radiology. , 2001, Radiation protection dosimetry.

[10]  R. Padovani,et al.  Staff dosimetry protocols in interventional radiology. , 2001, Radiation protection dosimetry.

[11]  E Vañó,et al.  Patient dose related to the complexity of interventional cardiology procedures. , 2001, Radiation protection dosimetry.

[12]  R. Padovani,et al.  Staff dosimetry in interventional cardiology. , 2001, Radiation protection dosimetry.

[13]  C J Martin,et al.  Radiation doses to the legs of radiologists performing interventional procedures: are they a cause for concern? , 2003, The British journal of radiology.

[14]  C. Martin,et al.  Application of ALARP to extremity doses for hospital workers , 2003, Journal of radiological protection : official journal of the Society for Radiological Protection.

[15]  T. Komppa,et al.  Occupational dose constraints in interventional cardiology procedures: the DIMOND approach. , 2004, Physics in medicine and biology.

[16]  E Vano,et al.  Correlation of patient and staff doses in interventional cardiology. , 2005, Radiation protection dosimetry.

[17]  R. Mini,et al.  Radiation Exposure to the Surgeon During Fluoroscopically Assisted Percutaneous Vertebroplasty: A Prospective Study , 2005, Spine.

[18]  C J Martin,et al.  A study of the distribution of dose across the hands of interventional radiologists and cardiologists. , 2005, The British journal of radiology.

[19]  E. Picano,et al.  Sustainability in the cardiac cath lab , 2007, The International Journal of Cardiovascular Imaging.

[20]  F. Vanhavere,et al.  The use of extremity dosemeters in a hospital environment. , 2006, Radiation protection dosimetry.

[21]  E Vano,et al.  Influence of patient thickness and operation modes on occupational and patient radiation doses in interventional cardiology. , 2006, Radiation protection dosimetry.

[22]  D. Winfield,et al.  A comparative analysis of radiological and surgical placement of central venous catheters , 1997, CardioVascular and Interventional Radiology.

[23]  L. Malone,et al.  Staff Radiation Doses to the Lower Extremities in Interventional Radiology , 2007, CardioVascular and Interventional Radiology.

[24]  P. Karaiskos,et al.  Level of patient and operator dose in the largest cardiac centre in Greece. , 2008, Radiation protection dosimetry.

[25]  T. Wøhni,et al.  Assessment of effective dose and dose to the lens of the eye for the interventional cardiologist. , 2008, Radiation protection dosimetry.

[26]  Mythreyi Bhargavan,et al.  TRENDS IN THE UTILIZATION OF MEDICAL PROCEDURES THAT USE IONIZING RADIATION , 2008, Health physics.