Joint estimation of activity image and attenuation sinogram using time-of-flight positron emission tomography data consistency condition filtering

Abstract. Attenuation correction is essential for quantitative reliability of positron emission tomography (PET) imaging. In time-of-flight (TOF) PET, attenuation sinogram can be determined up to a global constant from noiseless emission data due to the TOF PET data consistency condition. This provides the theoretical basis for jointly estimating both activity image and attenuation sinogram/image directly from TOF PET emission data. Multiple joint estimation methods, such as maximum likelihood activity and attenuation (MLAA) and maximum likelihood attenuation correction factor (MLACF), have already been shown that can produce improved reconstruction results in TOF cases. However, due to the nonconcavity of the joint log-likelihood function and Poisson noise presented in PET data, the iterative method still requires proper initialization and well-designed regularization to prevent convergence to local maxima. To address this issue, we propose a joint estimation of activity image and attenuation sinogram using the TOF PET data consistency condition as an attenuation sinogram filter, and then evaluate the performance of the proposed method using computer simulations.

[1]  Grant T. Gullberg,et al.  Toward accurate attenuation correction in SPECT without transmission measurements , 1997, IEEE Transactions on Medical Imaging.

[2]  M. Defrise,et al.  A fast rebinning algorithm for 3D positron emission tomography using John's equation , 1999 .

[3]  M. Conti Why is TOF PET reconstruction a more robust method in the presence of inconsistent data? , 2011, Physics in medicine and biology.

[4]  Jong Beom Ra,et al.  Dynamic PET reconstruction using temporal patch-based low rank penalty for ROI-based brain kinetic analysis , 2015, Physics in medicine and biology.

[5]  Maurizio Conti,et al.  First experimental results of time-of-flight reconstruction on an LSO PET scanner , 2007, Physics in medicine and biology.

[6]  Y. Censor,et al.  A New Approach to the Emission Computerized Tomography Problem: Simultaneous Calculation of Attenuation and Activity Coefficients , 1979, IEEE Transactions on Nuclear Science.

[7]  A. V. Bronnikov,et al.  Reconstruction of attenuation map using discrete consistency conditions , 2000, IEEE Transactions on Medical Imaging.

[8]  Johan Nuyts,et al.  ML-reconstruction for TOF-PET with simultaneous estimation of the attenuation factors , 2014, 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC).

[9]  Vladimir Y. Panin,et al.  A method of attenuation map and emission activity reconstructions from emission data , 1999 .

[10]  Patrick Dupont,et al.  Simultaneous maximum a posteriori reconstruction of attenuation and activity distributions from emission sinograms , 1999, IEEE Transactions on Medical Imaging.

[11]  Christian Michel,et al.  Application of discrete data consistency conditions for selecting regularization parameters in PET attenuation map reconstruction. , 2004, Physics in medicine and biology.

[12]  M. Defrise,et al.  Time-of-flight PET data determine the attenuation sinogram up to a constant , 2012, Physics in medicine and biology.

[13]  Alvaro R. De Pierro,et al.  Fast EM-like methods for maximum "a posteriori" estimates in emission tomography , 2001, IEEE Transactions on Medical Imaging.

[14]  Frank Natterer,et al.  Determination of tissue attenuation in emission tomography of optically dense media , 1993 .

[15]  Johan Nuyts,et al.  Transmission-less attenuation correction in time-of-flight PET: analysis of a discrete iterative algorithm , 2014, Physics in medicine and biology.

[16]  Maurizio Conti,et al.  Simultaneous Reconstruction of Activity and Attenuation in Time-of-Flight PET , 2012, IEEE Transactions on Medical Imaging.

[17]  Vladimir Y. Panin,et al.  Continuous and Discrete Data Rebinning in Time-of-Flight PET , 2008, IEEE Transactions on Medical Imaging.

[18]  James E. Bowsher,et al.  An EM algorithm for estimating SPECT emission and transmission parameters from emission data only , 2001, IEEE Transactions on Medical Imaging.

[19]  W. Segars,et al.  4D XCAT phantom for multimodality imaging research. , 2010, Medical physics.

[20]  Samuel Matej,et al.  Transmission-less attenuation estimation from time-of-flight PET histo-images using consistency equations , 2015, Physics in medicine and biology.

[21]  Suleman Surti,et al.  Benefit of Time-of-Flight in PET: Experimental and Clinical Results , 2008, Journal of Nuclear Medicine.

[22]  Til Aach,et al.  Simultaneous Reconstruction of Activity and Attenuation for PET/MR , 2011, IEEE Transactions on Medical Imaging.

[23]  Johan Nuyts,et al.  ML-Reconstruction for TOF-PET With Simultaneous Estimation of the Attenuation Factors , 2014, IEEE Transactions on Medical Imaging.

[24]  Alvaro R. De Pierro,et al.  Activity and attenuation recovery from activity data only in emission computed tomography , 2006 .

[25]  Jong Chul Ye,et al.  Fully 3D iterative scatter-corrected OSEM for HRRT PET using a GPU. , 2011, Physics in medicine and biology.