Modeling and visualization techniques for virtual stenting of aneurysms and stenoses

In this work, we present modeling and visualization techniques for virtual stenting of aneurysms and stenoses. In particular, contributions to support the computer-aided treatment of artery diseases - artery enlargement (aneurysm) and artery contraction (stenosis) - are made. If an intervention takes place, there are two different treatment alternatives for this kind of artery diseases: open surgery and minimally invasive (endovascular) treatment. Computer-assisted optimization of endovascular treatments is the main focus of our work. In addition to stent simulation techniques, we also present a computer-aided simulation of endoluminal catheters to support the therapy-planning phase. The stent simulation is based on a three-dimensional Active Contour Method and is applicable to both non-bifurcated (I-stents) and bifurcated stents (Y-stents). All methods are introduced in detail and are evaluated with phantom datasets as well as with real patient data from the clinical routine. Additionally, the clinical prototype that is based upon these methods is described.

[1]  Krishna Subramanyan,et al.  Automatic vessel extraction and abdominal aortic stent planning in multislice CT , 2002, SPIE Medical Imaging.

[2]  Christian Nøhr,et al.  Comparing Approaches to Measuring the Adoption and Usability of Electronic Health Records: Lessons Learned from Canada, Denmark and Finland , 2013, MedInfo.

[3]  Cornelis H. Slump,et al.  Initial steps towards automatic segmentation of the wire frame of stent grafts in CT data , 2009, EMBC 2009.

[4]  William H. Press,et al.  The Art of Scientific Computing Second Edition , 1998 .

[5]  Jan D. Blankensteijn,et al.  Preoperative Sizing of Grafts for Transfemoral Endovascular Aneurysm Management: A Prospective Comparative Study of Spiral CT Angiography, Arteriography, and Conventional CT Imaging , 1997 .

[6]  Bernd Freisleben,et al.  A software system for stent planning, stent simulation and follow-up examinations in the vascular domain , 2009, 2009 22nd IEEE International Symposium on Computer-Based Medical Systems.

[7]  Stephane Cotin,et al.  Physics-based models for catheter, guidewire and stent simulation. , 2006, Studies in health technology and informatics.

[8]  H. Bleuler,et al.  A Computer-Based Real-Time Simulation of Interventional Radiology , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[9]  Bernd Freisleben,et al.  Graph-based Tracking Method for Aortic Thrombus Segmentation , 2009 .

[10]  Bernd Freisleben,et al.  Detection and visualization of endoleaks in CT data for monitoring of thoracic and abdominal aortic aneurysm stents , 2016, SPIE Medical Imaging.

[11]  Edsger W. Dijkstra,et al.  A note on two problems in connexion with graphs , 1959, Numerische Mathematik.

[12]  Bernd Freisleben,et al.  PREOPERATIVE MEASUREMENT OF ANEURYSMS AND STENOSIS AND STENTSIMULATION FOR ENDOVASCULAR TREATMENT , 2007, 2007 4th IEEE International Symposium on Biomedical Imaging: From Nano to Macro.

[13]  David M. Williams,et al.  Endograft Planning without Preoperative Arteriography: A Clinical Feasibility Study , 2000, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[14]  Albert C. S. Chung,et al.  Augmented vessels for quantitative analysis of vascular abnormalities and endovascular treatment planning , 2006, IEEE Transactions on Medical Imaging.

[15]  Bernd Freisleben,et al.  Aorta Segmentation for Stent Simulation , 2011, ArXiv.

[16]  Bernd Freisleben,et al.  Simulation of bifurcated stent grafts to treat abdominal aortic aneurysms (AAA) , 2007, SPIE Medical Imaging.

[17]  Dinesh Manocha,et al.  LU-GPU: Efficient Algorithms for Solving Dense Linear Systems on Graphics Hardware , 2005, ACM/IEEE SC 2005 Conference (SC'05).

[18]  Winston Bonetti Yoshida,et al.  Aortic aneurysm surgery: problems and innovations , 2009 .

[19]  Roberto Pozzi-Mucelli,et al.  Virtual stenting of iliac arteries: a new technique for choosing stents and stent-grafts by means of 3D rotational angiography. Preliminary data. , 2004, La Radiologia medica.

[20]  J Martin Bland,et al.  Restenosis After Carotid Angioplasty, Stenting, or Endarterectomy in the Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS) , 2005 .

[21]  Jan Egger,et al.  Aortic volume as an indicator of disease progression in patients with untreated infrarenal abdominal aneurysm. , 2012, European journal of radiology.

[22]  H. Imamura,et al.  Preoperative and intraoperative image processing for assisting endovascular stent grafting , 2004, International Conference on Informatics Research for Development of Knowledge Society Infrastructure, 2004. ICKS 2004..

[23]  T. Bajwa,et al.  Protected carotid-artery stenting versus endarterectomy in high-risk patients. , 2004, The New England journal of medicine.

[24]  Zhonghua Sun,et al.  Multislice CT Angiography of Fenestrated Endovascular Stent Grafting for Treating Abdominal Aortic Aneurysms: a Pictorial Review of the 2D/3D Visualizations , 2009, Korean journal of radiology.

[25]  Sung Yun Park,et al.  Finite element analysis of stent expansion considering stent, artery and plaque interaction , 2006 .

[26]  Christopher Nimsky,et al.  Determination, Calculation and Representation of the Upper and Lower Sealing Zones During Virtual Stenting of Aneurysms , 2013, ArXiv.

[27]  S. Johnston,et al.  Treatment of unruptured cerebral aneurysms in California. , 2001, Stroke.

[28]  Johan Montagnat,et al.  3D graphical models for vascular-stent pose simulation , 2002 .

[29]  Bernd Freisleben,et al.  A Fast Vessel Centerline Extraction Algorithm for Catheter Simulation , 2007, Twentieth IEEE International Symposium on Computer-Based Medical Systems (CBMS'07).

[30]  Bernd Freisleben,et al.  Virtual Stenting for Carotid Stenosis with Elastic Artery Wall Modeling , 2009 .

[31]  Dorin Comaniciu,et al.  Hierarchical parsing and semantic navigation of full body CT data , 2009, Medical Imaging.

[32]  Demetri Terzopoulos,et al.  Snakes: Active contour models , 2004, International Journal of Computer Vision.

[33]  Erik Buskens,et al.  Two-Year Outcomes after Conventional or Endovascular Repair of Abdominal Aortic Aneurysms , 2005 .

[34]  J. Egger,et al.  Fast self-collision detection and simulation of bifurcated stents to treat abdominal aortic aneurysms (AAA) , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[35]  S D Wall,et al.  Endoleak after endovascular repair of abdominal aortic aneurysm. , 2001, Journal of vascular surgery.

[36]  Gino van den Bergen Efficient Collision Detection of Complex Deformable Models using AABB Trees , 1997, J. Graphics, GPU, & Game Tools.

[37]  Alejandro F. Frangi,et al.  Stent deployment in aneurysmatic cerebral vessels: Assessment and quantification of the differences be tween Fast Virtual Stenting and Finite Element Analysis , 2009 .

[38]  Tomas Akenine-Möller,et al.  Fast, Minimum Storage Ray-Triangle Intersection , 1997, J. Graphics, GPU, & Game Tools.

[39]  A. James O'Malley,et al.  Endovascular versus open repair of abdominal aortic aneurysms in the Medicare population , 2008 .

[40]  Søren Jacob Bakke,et al.  [Carotis stenosis-open surgery and endovascular treatment]. , 2009, Tidsskrift for den Norske laegeforening : tidsskrift for praktisk medicin, ny raekke.

[41]  M V Griffiths,et al.  Tracheal stenting: a better method of dealing with airway obstruction due to thyroid malignancies than tracheostomy. , 2004, The Journal of laryngology and otology.

[42]  Christopher Nimsky,et al.  Body landmark detection for a fully automatic AAA stent graft planning software system , 2010, 2010 IEEE 23rd International Symposium on Computer-Based Medical Systems (CBMS).

[43]  Demetri Terzopoulos,et al.  Constraints on Deformable Models: Recovering 3D Shape and Nonrigid Motion , 1988, Artif. Intell..

[44]  Rodney A. White,et al.  Stent graft migration after endovascular aneurysm repair: importance of proximal fixation. , 2003, Journal of vascular surgery.

[45]  Yu-Fai Fung,et al.  A PC based parallel LU decomposition algorithm for sparse matrices , 2003, 2003 IEEE Pacific Rim Conference on Communications Computers and Signal Processing (PACRIM 2003) (Cat. No.03CH37490).

[46]  Gene H. Golub,et al.  Matrix computations , 1983 .

[47]  Ron Kikinis,et al.  Statistical validation of image segmentation quality based on a spatial overlap index. , 2004, Academic radiology.

[48]  R. Rosenwasser,et al.  Stent-assisted coil placement for unruptured cerebral aneurysms. , 2004, Neurosurgical focus.

[49]  Zhou Wang,et al.  Measuring Intra- and Inter-Observer Agreement in Identifying and Localizing Structures in Medical Images , 2006, 2006 International Conference on Image Processing.

[50]  Rainald Löhner,et al.  Simulation of intracranial aneurysm stenting: Techniques and challenges , 2009 .

[51]  C. Ruggiero Proceedings of the 24th IASTED international conference on Biomedical engineering , 2006 .