Signal conditioning units for vibration measurement in HUMS

A signal conditioning units for vibration measurement in HUMS is proposed in the paper. Due to the frequency of vibrations caused by components in helicopter are different, two steps amplifier and programmable anti-aliasing filter are designed to meet the measurement of different types of helicopter. Vibration signals are converted into measurable electrical signals combing with ICP driver firstly. Then pre-amplifier and programmable gain amplifier is applied to magnify the weak electrical signals. In addition, programmable anti-aliasing filter is utilized to filter the interference of noise. The units were tested using function signal generator and oscilloscope. The experimental results have demonstrated the effectiveness of our proposed method in quantitatively and qualitatively. The method presented in this paper can meet the measurement requirement for different types of helicopter.

[1]  Chuck Trammel,et al.  UK Ministry of Defence generic health and usage monitoring system (GenHUMS) , 1997 .

[2]  Michael J. Augustin,et al.  Implementing Hums In The Military Operational Environment , 2001 .

[3]  Charles R Farrar,et al.  Damage prognosis: the future of structural health monitoring , 2007, Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences.

[4]  Andrew Hess,et al.  SH-60 helicopter integrated diagnostic system (HIDS) program-diagnostic and prognostic development experience , 1999, 1999 IEEE Aerospace Conference. Proceedings (Cat. No.99TH8403).