IMU-based Smart Knee Pad for Walking Distance and Stride Count Measurement

To calculate the knee angle, stride counts, and walking distance, we propose a system, iKneePad, fusing two 9-axis sensors with Bluetooth equipped on the thigh and shank segments. The changing rates of hip and knee angles are used to determine the beginning and the ending of a stride. The thigh length, shank length, hip angle, and knee angle are used to calculate the walking distance. The experimental results show that the accuracy of stride count is 100%, the absolute mean errors of knee angle are 2.99° and 1.42° for the maximum and minimum flexion angles, respectively. For walking distance, the mean error rates are −2.40% and −2.26% for short (10m) and long (33m) distances, respectively. The proposed system also instantly provides feedback to users by showing on an Android smartphone when conducting rehabilitation or exercise with iKneePad.

[1]  S. Olney,et al.  Multivariate examination of data from gait analysis of persons with stroke. , 1998, Physical therapy.

[2]  Alison H. McGregor,et al.  A flexible wearable sensor for knee flexion assessment during gait , 2018, Gait & posture.

[3]  D. Alvarez,et al.  Multisensor Approach to Walking Distance Estimation with Foot Inertial Sensing , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[4]  A K Bourke,et al.  Activity classification using a single chest mounted tri-axial accelerometer. , 2011, Medical engineering & physics.

[5]  Philip C. Noble,et al.  Is digital photography an accurate and precise method for measuring range of motion of the hip and knee? , 2017, Journal of Experimental Orthopaedics.

[6]  P ? ? ? ? ? ? ? % ? ? ? ? , 1991 .

[7]  Walter Higgins,et al.  A Comparison of Complementary and Kalman Filtering , 1975, IEEE Transactions on Aerospace and Electronic Systems.

[8]  Daniel T H Lai,et al.  Swing limb mechanics and minimum toe clearance in people with knee osteoarthritis. , 2012, Gait & posture.

[9]  Yusuke Moriya,et al.  Postural deformities in Parkinson’s disease –Mutual relationships among neck flexion, fore-bent, knee-bent and lateral-bent angles and correlations with clinical predictors , 2016, Journal of Clinical Movement Disorders.

[10]  Jan Rueterbories,et al.  Methods for gait event detection and analysis in ambulatory systems. , 2010, Medical engineering & physics.

[11]  Edward D Lemaire,et al.  Novel algorithm for a smartphone-based 6-minute walk test application: algorithm, application development, and evaluation , 2015, Journal of NeuroEngineering and Rehabilitation.

[12]  Scott E. Crouter,et al.  Step Counting: A Review of Measurement Considerations and Health-Related Applications , 2016, Sports Medicine.

[13]  Janice K. Loudon,et al.  The Clinical Orthopedic Assessment Guide , 1998 .

[14]  A Leardini,et al.  Cruciate ligament forces in the human knee during rehabilitation exercises. , 2000, Clinical biomechanics.

[15]  I. Jonkers,et al.  Quantitative gait analysis in Parkinson's disease: comparison with a healthy control group. , 2005, Archives of physical medicine and rehabilitation.

[16]  Athanasios Katis,et al.  Knee biomechanics of the support leg in soccer kicks from three angles of approach. , 2004, Medicine and science in sports and exercise.

[17]  Thomas Seel,et al.  Realtime assessment of foot orientation by Accelerometers and Gyroscopes , 2015 .

[18]  Patria A Hume,et al.  Effects of Bicycle Saddle Height on Knee Injury Risk and Cycling Performance , 2011, Sports medicine.

[19]  K. An,et al.  Gait characteristics of patients with knee osteoarthritis. , 2001, Journal of biomechanics.

[20]  Tao Liu,et al.  Gait Analysis Using Wearable Sensors , 2012, Sensors.

[21]  Rainer Bader,et al.  Accuracy of a Custom Physical Activity and Knee Angle Measurement Sensor System for Patients with Neuromuscular Disorders and Gait Abnormalities , 2015, Sensors.

[22]  Dirman Hanafi,et al.  Knee joint angle measurement system using gyroscope and flex-sensors for rehabilitation , 2013, The 6th 2013 Biomedical Engineering International Conference.

[23]  Gu-Min Jeong,et al.  Stride Counting in Human Walking and Walking Distance Estimation Using Insole Sensors , 2016, Sensors.

[24]  R. Wootton,et al.  Can the Internet be used as a medium to evaluate knee angle? , 2003, Manual therapy.

[25]  Thomas Seel,et al.  Experimental Evaluation of a Novel Inertial Sensor Based Realtime Gait Phase De-tection Algorithm , 2015 .

[26]  Corina Nüesch,et al.  Measuring joint kinematics of treadmill walking and running: Comparison between an inertial sensor based system and a camera-based system. , 2017, Journal of biomechanics.