Optimization of a flat-panel based real time dual-energy system for cardiac imaging.

A simulation study was conducted to evaluate the effects of high-energy beam filtration, dual-gain operation and noise reduction on dual-energy images using a digital flat-panel detector. High-energy beam filtration increases image contrast through greater beam separation and tends to reduce total radiation exposure and dose per image pair. It is also possible to reduce dual-energy image noise by acquiring low and high-energy images at two different detector gains. In addition, dual-energy noise reduction algorithms can further reduce image noise. The cumulative effect of these techniques applied in series was investigated in this study. The contrast from a small thickness of calcium was simulated over a step phantom of tissue equivalent material with a CsI phosphor as the image detector. The dual-energy contrast-to-noise ratio was calculated using values of energy absorption and energy variance. A figure-of-merit (FOM) was calculated from dual-energy contrast-to-noise ratio (CNR) and patient effective dose estimated from values of entrance exposure. Filter atomic numbers in the range of 1-100 were considered with thicknesses ranging from 0-2500 mg/cm2. The simulation examined combinations of the above techniques which maximized the FOM. The application of a filter increased image contrast by as much as 45%. Near maximal increases were seen for filter atomic numbers in the range of 40-60 and 85-100 with masses above 750 mg/cm2. Increasing filter thickness beyond 1000 mg/cm2 increased tube loading without further significant contrast enhancement. No additional FOM improvements were seen with dual gain before or after the application of any noise reduction algorithm. Narrow beam experiments were carried out to verify predictions. The measured FOM increased by more than a factor of 3.5 for a silver filter thickness of 800 microm, equal energy weighting and application of a noise clipping algorithm. The main limitation of dynamic high-energy filtration is increased tube loading. The results of this study can be used to help develop an optimal dual-energy imaging system.

[1]  Bernhard Erich Hermann Claus,et al.  Development and characterization of a dual-energy subtraction imaging system for chest radiography based on CsI:Tl amorphous silicon flat-panel technology , 2001, SPIE Medical Imaging.

[2]  James T. Dobbins,et al.  Recent progress in noise reduction and scatter correction in dual-energy imaging , 1995, Medical Imaging.

[3]  J C Le Heron,et al.  Estimation of effective dose to the patient during medical x-ray examinations from measurements of the dose-area product. , 1992 .

[4]  Michael S. Van Lysel Optimization of beam parameters for dual-energy digital subtraction angiography. , 1994 .

[5]  R. Alvarez,et al.  Comparison of dual energy detector system performance. , 2004, Medical physics.

[6]  M J Yaffe,et al.  Theoretical optimization of dual-energy x-ray imaging with application to mammography. , 1985, Medical physics.

[7]  W R Brody,et al.  Noise reduction methods for hybrid subtraction. , 1984, Medical physics.

[8]  J. Boone,et al.  An accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kV. , 1997, Medical physics.

[9]  James T Dobbins,et al.  Quantitative , 2020, Psychology through Critical Auto-Ethnography.

[10]  C A Mistretta,et al.  A correlated noise reduction algorithm for dual-energy digital subtraction angiography. , 1989, Medical physics.

[11]  W. Kalender,et al.  An algorithm for noise suppression in dual energy CT material density images. , 1988, IEEE transactions on medical imaging.

[12]  J A Sorenson,et al.  Simulation studies of dual-energy x-ray absorptiometry. , 1989, Medical physics.

[13]  J M Boone,et al.  Comparison of x-ray cross sections for diagnostic and therapeutic medical physics. , 1996, Medical physics.

[14]  E. Samei,et al.  A method for measuring the presampled MTF of digital radiographic systems using an edge test device. , 1998, Medical physics.

[15]  C A Mistretta,et al.  Quantification techniques for dual-energy cardiac imaging. , 1989, Medical physics.