Age-dependent properties and quasi-static strain in the rat sagittal suture.

We measured the morphology of and performed tensile tests on sagittal sutures from rats of postnatal age 2 to 60 days. Using the properties measured ex vivo and a pressure vessel-based analysis, we estimated the quasi-static strain that had existed in the suture in vivo from 2 to 60 days. Sutural thickness, width, and stiffness per length were notable properties found to be age dependent. Sutural thickness increased 4.5-fold (0.11-0.50mm) between 2 and 60 days. Sutural width increased transiently between 2 and 20 days, peaking around 8 days; at 8 days, mean sutural width was 75% larger than mean sutural width at two days (0.35+/-0.07 (SD) vs. 0.20+/-0.06 mm). Sutural stiffness per length increased 4.4-fold (8.77-38.3N/mm/mm) between 2 and 60 days. The quasi-static sutural strain estimated to exist in vivo averaged 270+/-190 muepsilon between 2 and 60 days and was not age dependent. These findings provide data on the age-dependent sutural properties of infant to mature rats and provide the first estimate of quasi-static sutural strain in vivo in the rat. The findings show that during development the rat sagittal suture, as a structure, changes significantly and is exposed to quasi-static tensile strain in vivo due to intracranial pressure.

[1]  Michael T Longaker,et al.  Sutural bone deposition rate and strain magnitude during cranial development. , 2004, Bone.

[2]  R. Deane,et al.  Developmental changes in cerebrospinal fluid pressure and resistance to absorption in rats. , 1987, Brain research.

[3]  Stanton A. Glantz,et al.  Primer of biostatistics : statistical software program version 6.0 , 1981 .

[4]  J. Mao,et al.  Nanomechanical Properties of Facial Sutures and Sutural Mineralization Front , 2004, Journal of dental research.

[5]  S. Margulies,et al.  Infant skull and suture properties: measurements and implications for mechanisms of pediatric brain injury. , 2000, Journal of biomechanical engineering.

[6]  F. Noyes,et al.  The strength of the anterior cruciate ligament in humans and Rhesus monkeys. , 1976, The Journal of bone and joint surgery. American volume.

[7]  M. Longaker,et al.  Mechanical Strain Affects Dura Mater Biological Processes: Implications for Immature Calvarial Healing , 2003, Plastic and reconstructive surgery.

[8]  D. Pashley,et al.  The load-displacement characteristics of neonatal rat cranial sutures. , 2000, The Cleft palate-craniofacial journal : official publication of the American Cleft Palate-Craniofacial Association.

[9]  C. Jaslow Mechanical properties of cranial sutures. , 1990, Journal of biomechanics.

[10]  H. Fuchs,et al.  Sutural mineralization of rat calvaria characterized by atomic-force microscopy and transmission electron microscopy , 1998, Cell and Tissue Research.

[11]  E. Tanaka,et al.  Changes in the biomechanical properties of the rat interparietal suture incident to continuous tensile force application. , 2000, Archives of oral biology.

[12]  R. Nanda,et al.  Effect of tensile force magnitude on release of cranial suture cells into S phase. , 1987, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[13]  S. Mcgee-Russell HISTOCHEMICAL METHODS FOR CALCIUM , 1958, The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society.