Improving Signal-to-Noise Ratio in Susceptibility Weighted Imaging: A Novel Multicomponent Non-Local Approach

In susceptibility-weighted imaging (SWI), the high resolution required to obtain a proper contrast generation leads to a reduced signal-to-noise ratio (SNR). The application of a denoising filter to produce images with higher SNR and still preserve small structures from excessive blurring is therefore extremely desirable. However, as the distributions of magnitude and phase noise may introduce biases during image restoration, the application of a denoising filter is non-trivial. Taking advantage of the potential multispectral nature of MR images, a multicomponent approach using a Non-Local Means (MNLM) denoising filter may perform better than a component-by-component image restoration method. Here we present a new MNLM-based method (Multicomponent-Imaginary-Real-SWI, hereafter MIR-SWI) to produce SWI images with high SNR and improved conspicuity. Both qualitative and quantitative comparisons of MIR-SWI with the original SWI scheme and previously proposed SWI restoring pipelines showed that MIR-SWI fared consistently better than the other approaches. Noise removal with MIR-SWI also provided improvement in contrast-to-noise ratio (CNR) and vessel conspicuity at higher factors of phase mask multiplications than the one suggested in the literature for SWI vessel imaging. We conclude that a proper handling of noise in the complex MR dataset may lead to improved image quality for SWI data.

[1]  Bruno Alfano,et al.  Unbiased noise estimation and denoising in parallel magnetic resonance imaging , 2014, 2014 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP).

[2]  R. Grossman,et al.  Characterizing iron deposition in multiple sclerosis lesions using susceptibility weighted imaging , 2009, Journal of magnetic resonance imaging : JMRI.

[3]  Dong-Hyun Kim,et al.  Improvement of the SNR and resolution of susceptibility-weighted venography by model-based multi-echo denoising , 2013, NeuroImage.

[4]  Pierrick Coupé,et al.  Rician Noise Removal by Non-Local Means Filtering for Low Signal-to-Noise Ratio MRI: Applications to DT-MRI , 2008, MICCAI.

[5]  E. Mark Haacke,et al.  Correlation of hypointensities in susceptibility-weighted images to tissue histology in dementia patients with cerebral amyloid angiopathy: a postmortem MRI study , 2010, Acta Neuropathologica.

[6]  E. Mark Haacke,et al.  Susceptibility Weighted Imaging in MRI: Basic Concepts and Clinical Applications , 2011 .

[7]  Sandeep Mittal,et al.  Identification of calcification with MRI using susceptibility‐weighted imaging: A case study , 2009, Journal of magnetic resonance imaging : JMRI.

[8]  E. Haacke,et al.  Quantitative susceptibility mapping: current status and future directions. , 2015, Magnetic resonance imaging.

[9]  Yu-Chung N. Cheng,et al.  Susceptibility weighted imaging (SWI) , 2004, Zeitschrift fur medizinische Physik.

[10]  Y. Cheng,et al.  Susceptibility mapping as a means to visualize veins and quantify oxygen saturation , 2010, Journal of magnetic resonance imaging : JMRI.

[11]  Jaladhar Neelavalli,et al.  Clinical applications of neuroimaging with susceptibility‐weighted imaging , 2005, Journal of magnetic resonance imaging : JMRI.

[12]  Salvatore Cuomo,et al.  3D Non-Local Means denoising via multi-GPU , 2013, 2013 Federated Conference on Computer Science and Information Systems.

[13]  S. Schoenberg,et al.  Influence of multichannel combination, parallel imaging and other reconstruction techniques on MRI noise characteristics. , 2008, Magnetic resonance imaging.

[14]  H. Gudbjartsson,et al.  The rician distribution of noisy mri data , 1995, Magnetic resonance in medicine.

[15]  Jean-Michel Morel,et al.  Image Denoising Methods. A New Nonlocal Principle , 2010, SIAM Rev..

[16]  Kuncheng Li,et al.  Visualization of carotid plaque calcification - a novel approach using susceptibility weighted MR imaging , 2010 .

[17]  Pierrick Coupé,et al.  An Optimized Blockwise Nonlocal Means Denoising Filter for 3-D Magnetic Resonance Images , 2008, IEEE Transactions on Medical Imaging.

[18]  Neil A. Thacker,et al.  Multicomponent MR Image Denoising , 2009, Int. J. Biomed. Imaging.

[19]  B. Alfano,et al.  Improving SNR in Susceptibility Weighted Imaging by a NLM-based denoising scheme , 2014, 2014 IEEE International Conference on Imaging Systems and Techniques (IST) Proceedings.

[20]  Z. Wu,et al.  Susceptibility-Weighted Imaging: Technical Aspects and Clinical Applications, Part 2 , 2008, American Journal of Neuroradiology.

[21]  R. Cusack,et al.  New Robust 3-D Phase Unwrapping Algorithms: Application to Magnetic Field Mapping and Undistorting Echoplanar Images , 2002, NeuroImage.

[22]  E. Haacke,et al.  Susceptibility-Weighted Imaging: Technical Aspects and Clinical Applications, Part 1 , 2008, American Journal of Neuroradiology.

[23]  E M Haacke,et al.  Imaging cerebral amyloid angiopathy with susceptibility-weighted imaging. , 2007, AJNR. American journal of neuroradiology.

[24]  Jiani Hu,et al.  Improving detection of siderotic nodules in cirrhotic liver with a multi‐breath‐hold susceptibility‐weighted imaging technique , 2011, Journal of magnetic resonance imaging : JMRI.

[25]  Yingbiao Xu,et al.  The role of voxel aspect ratio in determining apparent vascular phase behavior in susceptibility weighted imaging. , 2006, Magnetic resonance imaging.

[26]  José V. Manjón,et al.  MRI denoising using Non-Local Means , 2008, Medical Image Anal..

[27]  Jaladhar Neelavalli,et al.  Susceptibility‐weighted imaging to visualize blood products and improve tumor contrast in the study of brain masses , 2006, Journal of magnetic resonance imaging : JMRI.