Interharmonic - Flicker Curves of Lamps and Compatibility Lever for Interharmonic Voltages

The aim of the paper is to describe procedures for systematical determination of immunity of lamps to supply voltage variations caused by interharmonics. The curve of lamp immunity is presented as an interharmonic magnitude versus interharmonic frequency curve and is called interharmonic-flicker curve. The interharmonic-flicker curves of lamps are determined by utilizing a modified concept for measurement of a lamp gain factor in frequency domain and by utilizing the published limits on voltage flicker. Another described method for establishing the interharmonic-flicker curves of lamps is the method based on measuring the luminous flux flicker curve which is defined by utilizing the published limits on voltage flicker as well. Further a complex measured data file of interharmonic-flicker curves in various combinations of discharge lamps (fluorescent lamps and high intensity discharge lamps) and ballasts are pointed. Measured and compared combinations include various types of discharge lamps, various wattages, modes of operation of the ballast and its specific designs and dimensioning of circuit elements etc. Finally, determined interharmonic-flicker curves of chosen lamps are used for proposal approach how to revise the compatibility level for interharmonic voltages relating to flicker.

[1]  Wilsun Xu,et al.  Interharmonic-flicker curves , 2005, IEEE Transactions on Power Delivery.

[2]  Michael K. Walker,et al.  Electric Utility Flicker Limitations , 1979, IEEE Transactions on Industry Applications.

[3]  J. Drapela,et al.  Light flicker of fluorescent lamps with different types of ballasts caused by interharmonics , 2005, 2005 IEEE Russia Power Tech.

[4]  John E. Kaufman,et al.  IES lighting handbook , 1981 .

[5]  M. De Koster-E. De Jaeger,et al.  LIGHT FLICKER CAUSED BY INTERHARMONICS , 1999 .