A circulatory model for calculating non-steady-state glucose fluxes. Validation and comparison with compartmental models

This study presents a circulatory model of glucose kinetics for application to non-steady-state conditions, examines its ability to predict glucose appearance rates from a simulated oral glucose load, and compares its performance with compartmental models. A glucose tracer bolus was injected intravenously in rats to determine parameters of the circulatory and two-compartment models. A simulated oral glucose tolerance test was performed in another group of rats by infusing intravenously labeled glucose at variable rates. A primed continuous intravenous infusion of a second tracer was given to determine glucose clearance. The circulatory model gave the best estimate of glucose appearance, closely followed by the two-compartment model and a modified Steele one-compartment model with a larger total glucose volume. The standard one-compartment model provided the worst estimate. The average relative errors on the rate of glucose appearance were: circulatory, 10%; two-compartment, 13%; modified one-compartment, 11%; standard one-compartment, 16%. Recovery of the infused glucose dose was 93+/-2, 94+/-2, 92+/-2 and 85+/-2%, respectively. These results show that the circulatory model is an appropriate model for assessing glucose turnover during an oral glucose load.

[1]  Andrea Mari,et al.  Calculation of organ and whole-body uptake and production with the impulse response approach , 1995 .

[2]  A Mari,et al.  Glucose absorption and production following oral glucose: comparison of compartmental and arteriovenous-difference methods. , 1994, Metabolism: clinical and experimental.

[3]  K. Zierler,et al.  On the theory of the indicator-dilution method for measurement of blood flow and volume. , 1954, Journal of applied physiology.

[4]  N. Lassen,et al.  Tracer kinetic methods in medical physiology , 1979 .

[5]  Chi-Tsong Chen,et al.  Linear System Theory and Design , 1995 .

[6]  J. Proietto,et al.  Non-steady-state measurement of glucose turnover in rats by using a one-compartment model. , 1987, The American journal of physiology.

[7]  T. Ogihara,et al.  Mechanisms mediating postprandial blood pressure reduction in young and elderly subjects. , 1996, American journal of hypertension.

[8]  R. Steele,et al.  INFLUENCES OF GLUCOSE LOADING AND OF INJECTED INSULIN ON HEPATIC GLUCOSE OUTPUT * , 1959, Annals of the New York Academy of Sciences.

[9]  R N Bergman,et al.  Estimation of Endogenous Glucose Production During Hyperinsulinemic-Euglycemic Glucose Clamps: Comparison of Unlabeled and Labeled Exogenous Glucose Infusates , 1987, Diabetes.

[10]  A Mari,et al.  Assessment of insulin action on glucose uptake and production during a euglycemic-hyperinsulinemic clamp in dog: a new kinetic analysis. , 1997, Metabolism: clinical and experimental.

[11]  Mark W. Crawford,et al.  Hemodynamic and organ blood flow responses to halothane and sevoflurane anesthesia during spontaneous ventilation. , 1992 .

[12]  A Mari,et al.  Dose-response characteristics of insulin action on glucose metabolism: a non-steady-state approach. , 2000, American journal of physiology. Endocrinology and metabolism.

[13]  A. Baron,et al.  Hemodynamic actions of insulin. , 1994, The American journal of physiology.

[14]  A. Thorburn,et al.  Carbohydrate fermentation decreases hepatic glucose output in healthy subjects. , 1993, Metabolism: clinical and experimental.

[15]  J. Proietto,et al.  The feto-placental glucose steal phenomenon is a major cause of maternal metabolic adaptation during late pregnancy in the rat , 1994, Diabetologia.

[16]  A. Mari Determination of the single-pass impulse response of the body tissues with circulatory models , 1995, IEEE Transactions on Biomedical Engineering.

[17]  K. Zierler,et al.  Whole body glucose metabolism. , 1999, The American journal of physiology.

[18]  S. Jern,et al.  Effects of Acute Carbohydrate Administration on Central and Peripheral Hemodynamic Responses to Mental Stress , 1991, Hypertension.

[19]  A Mari,et al.  Estimation of the rate of appearance in the non-steady state with a two-compartment model. , 1992, The American journal of physiology.

[20]  Claudio Cobelli,et al.  A model of glucose kinetics and their control by insulin, compartmental and noncompartmental approaches , 1984 .

[21]  C Cobelli,et al.  Non-steady state: error analysis of Steele's model and developments for glucose kinetics. , 1987, The American journal of physiology.

[22]  K. Zierler,et al.  THEORY OF THE USE OF ARTERIOVENOUS CONCENTRATION DIFFERENCES FOR MEASURING METABOLISM IN STEADY AND NON-STEADY STATES. , 1961, The Journal of clinical investigation.

[23]  A Mari,et al.  Circulatory models of intact-body kinetics and their relationship with compartmental and non-compartmental analysis. , 1993, Journal of theoretical biology.

[24]  K.,et al.  Experimental validation of measurements of glucose turnover in nonsteady state. , 1978, The American journal of physiology.

[25]  K. Zierler,et al.  A critique of compartmental analysis. , 1981, Annual review of biophysics and bioengineering.