Investigation of twisted tape inserted solar water heaters—heat transfer, friction factor and thermal performance results

Heat transfer in a solar water heater could be enhanced by means of twisted tapes, inserted inside the fluid flow tubes, which induce swirl flow and act as turbulence promoters. Experimental investigations for a solar water heater with twisted tape inserts having twist pitch to tube diameter ratio ranging from 3–12 have been carried out for varying mass flow rates. The results on heat transfer and friction data have been found to compare well with available results. Within the range of investigated parameters, the heat transfer in the twisted tape insert collectors has been found to increase by 18–70%, whereas the pressure drop increased by 87–132%, as compared to plane collectors. An expression correlating the Nusselt numbers in twisted tape and plane collectors, the twist pitch ratio has been developed in the form of Nus/Nu=1.3+2.88/y, which predicts the heat transfer within the range of the present investigation. Results conclude that such collectors would be preferable for higher grade energy collection as it is also at higher rate.

[1]  A. W. Date,et al.  Prediction of fully-developed flow in a tube containing a twisted-tape , 1974 .

[2]  T. Reddy,et al.  Generating application design data for solar air heating systems , 1980 .

[3]  A. K. Jain,et al.  Accurate Explicit Equation for Friction Factor , 1976 .

[4]  Heat transfer augmentation in tubular flow by twisted tapes at high temperatures and optimum performance , 1983 .

[5]  S. A. Mumma,et al.  The application of ASHRAE Standard 93-77 to the thermal performance testing of air solar collectors , 1978 .

[6]  R. M. Manglik,et al.  Heat Transfer and Pressure Drop Correlations for Twisted-Tape Inserts in Isothermal Tubes: Part II—Transition and Turbulent Flows , 1993 .

[7]  B. N. Prasad,et al.  Effect of artificial roughness on heat transfer and friction factor in a solar air heater , 1988 .

[8]  A. E. Bergles,et al.  Heat Transfer and Pressure Drop in Tape-Generated Swirl Flow of Single-Phase Water , 1969 .

[9]  E. G. Plett,et al.  Thermal performance representation and testing of air solar collectors , 1988 .

[10]  Austin Whillier,et al.  Solar energy collection and its utilization for house heating , 1953 .

[11]  Blaine F. Parker,et al.  Derivation of efficiency and loss factors for solar air heaters , 1981 .

[12]  Raymond W. Bliss,et al.  The derivations of several ``Plate-efficiency factors'' useful in the design of flat-plate solar heat collectors , 1959 .

[13]  P. Biondi,et al.  Performance analysis of solar air heaters of conventional design , 1988 .

[14]  F. Landis,et al.  Friction and Forced Convection Heat-Transfer Characteristics in Tubes With Twisted Tape Swirl Generators , 1964 .