Analysis on Operational Improvement of OCR Using Voltage Component in a Power Distribution System for Application of SFCL

To protect the power systems from fault situations, the installations of protective equipment are inevitable and various types of protective devices have been installed in a power system. Overcurrent relays (OCRs), one of them, are basically used a lot in a power distribution system as a primary protective device. Recently, a rapid industrial development has made the power systems to be large. Accordingly, a fault current has been increased and a superconducting fault current limiter (SFCL), as a part of the countermeasure to reduce the fault current, has gotten a spotlight. Application of the SFCLs in the power system has abilities from the side of the fault current and ease voltage sag. However, this fault current reduction ability effects on the other protective equipment, like relaying, recloser and so on. Especially, in this paper, to reduce the effect on the trip operation of the OCR due to installation of the SFCL, the OCR using voltage component in a power distribution system has been suggested and the operational improvement of the proposed OCR has been analyzed through the PSCAD/EMTDC.

[1]  Seong-Woo Yim,et al.  Long-Term Operation and Fault Tests of a 22.9 kV Hybrid SFCL in the KEPCO Test Grid , 2011, IEEE Transactions on Applied Superconductivity.

[2]  Hatem Zeineldin,et al.  Optimal coordination of directional overcurrent relays using a new time-current-voltage characteristic , 2015, 2016 IEEE Power and Energy Society General Meeting (PESGM).

[3]  Sung-Hun Lim,et al.  Study on Improvement of Overcurernt Relay (OCR)’s Operation Due to Application of Superconducting Fault Current Limiter (SFCL) in Power Distribution System with a Dispersed Generation , 2017 .

[4]  Jae-Sun Huh,et al.  A Study on the Application of a Superconducting Fault Current Limiter for Energy Storage Protection in a Power Distribution System , 2013, IEEE Transactions on Applied Superconductivity.

[5]  Chul-Hwan Kim,et al.  Quench and Recovery Characteristics of a SFCL Applied Into Neutral Line of a Three-Phase Power System , 2009, IEEE Transactions on Applied Superconductivity.

[6]  H. Yamaguchi,et al.  Current limiting characteristics of transformer type superconducting fault current limiter , 2005, IEEE Transactions on Applied Superconductivity.

[7]  Chul-Won Park,et al.  A Study of the Operating Characteristic for Voltage Restrained Overcurrent Relay using the ATPDraw5.7p4 Modeling Data , 2012 .

[8]  Sung-Hun Lim,et al.  Analysis on Voltage Sag According to Impedance and Application Location of SFCL with Recloser-Recloser Coordination , 2014 .

[9]  C.J. Fourie,et al.  Simulated inductance variations in RSFQ circuit structures , 2005, IEEE Transactions on Applied Superconductivity.

[10]  Jae-Chul Kim,et al.  Study on Application Method of Superconducting Fault Current Limiter for Protection Coordination of Protective Devices in a Power Distribution System , 2012, IEEE Transactions on Applied Superconductivity.

[11]  J.H. Lim,et al.  Performance Test of 100 m HTS Power Cable System , 2009, IEEE Transactions on Applied Superconductivity.