Dual contactless conductivity and amperometric detection on hybrid PDMS/glass electrophoresis microchips.

A new approach for the integration of dual contactless conductivity and amperometric detection with an electrophoresis microchip system is presented. The PDMS layer with the embedded channels was reversibly sealed to a thin glass substrate (400 microm), on top of which a palladium electrode had been previously fabricated enabling end-channel amperometric detection. The thin glass substrate served also as a physical wall between the separation channel and the sensing copper electrodes for contactless conductivity detection. The latter were not integrated in the microfluidic device, but fabricated on an independent plastic substrate allowing a simpler and more cost-effective fabrication of the chip. PDMS/glass chips with merely contactless conductivity detection were first characterized in terms of sensitivity, efficiency and reproducibility. The separation efficiency of this system was found to be similar or slightly superior to other systems reported in the literature. The simultaneous determination of ionic and electroactive species was illustrated by the separation of peroxynitrite degradation products, i.e. NO(3)(-) (non-electroactive) and NO(2)(-) (electroactive), using hybrid PDMS/glass chips with dual contactless conductivity and amperometric detection. While both ions were detected by contactless conductivity detection with good efficiency, NO(2)(-) was also simultaneously detected amperometrically with a significant enhancement in sensitivity compared to contactless conductivity detection.

[1]  Balaraman Kalyanaraman,et al.  Peroxynitrite modification of low‐density lipoprotein leads to recognition by the macrophage scavenger receptor , 1993, FEBS letters.

[2]  M. N. Álvarez,et al.  Unraveling peroxynitrite formation in biological systems. , 2001, Free radical biology & medicine.

[3]  M. Brown,et al.  Lipoprotein metabolism in the macrophage: implications for cholesterol deposition in atherosclerosis. , 1983, Annual review of biochemistry.

[4]  Erkang Wang,et al.  Simultaneous electrochemical and electrochemiluminescence detection for microchip and conventional capillary electrophoresis , 2005, Electrophoresis.

[5]  J. Michael Ramsey,et al.  Microchip flow cytometry using electrokinetic focusing. , 1999, Analytical chemistry.

[6]  David J. Fischer,et al.  Recent developments in electrochemical detection for microchip capillary electrophoresis , 2004, Electrophoresis.

[7]  L. Moroz,et al.  High-resolution microanalysis of nitrite and nitrate in neuronal tissues by capillary electrophoresis with conductivity detection. , 2002, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[8]  G. Whitesides,et al.  Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane). , 1998, Analytical chemistry.

[9]  S. Lunte,et al.  Separation and detection of peroxynitrite and its metabolites by capillary electrophoresis with UV detection. , 2006, Journal of chromatography. A.

[10]  E. Carrilho,et al.  A toner-mediated lithographic technology for rapid prototyping of glass microchannels. , 2007, Lab on a chip.

[11]  C. Henry,et al.  Dual-electrode electrochemical detection for poly(dimethylsiloxane)-fabricated capillary electrophoresis microchips. , 2000, Analytical chemistry.

[12]  H. Jasin,et al.  Responses of lymphocytes of patients with rheumatoid arthritis to IgG modified by oxygen radicals or peroxynitrite. , 2005, Arthritis and rheumatism.

[13]  B. Freeman,et al.  Peroxynitrite-induced membrane lipid peroxidation: the cytotoxic potential of superoxide and nitric oxide. , 1991, Archives of biochemistry and biophysics.

[14]  Andreas E. Guber,et al.  High-voltage contactless conductivity-detection for lab-on-chip devices using external electrodes on the holder , 2003 .

[15]  Aaron R. Wheeler,et al.  Rapid Prototyping in Copper Substrates for Digital Microfluidics , 2007 .

[16]  W. Koppenol,et al.  Reaction of peroxynitrite with carbon dioxide: intermediates and determination of the yield of CO3•– and NO2• , 2001, JBIC Journal of Biological Inorganic Chemistry.

[17]  G. Whitesides,et al.  Fabrication of microfluidic systems in poly(dimethylsiloxane) , 2000, Electrophoresis.

[18]  G. Kojda,et al.  Interactions between NO and reactive oxygen species: pathophysiological importance in atherosclerosis, hypertension, diabetes and heart failure. , 1999, Cardiovascular research.

[19]  José Alberto Fracassi da Silva,et al.  A dry process for production of microfluidic devices based on the lamination of laser-printed polyester films. , 2003, Analytical chemistry.

[20]  S R Tannenbaum,et al.  The chemistry of DNA damage from nitric oxide and peroxynitrite. , 1999, Mutation research.

[21]  Jan Lichtenberg,et al.  A microchip electrophoresis system with integrated in‐plane electrodes for contactless conductivity detection , 2002, Electrophoresis.

[22]  B. Freeman,et al.  Peroxynitrite oxidation of sulfhydryls. The cytotoxic potential of superoxide and nitric oxide. , 1991, The Journal of biological chemistry.

[23]  Claudimir Lucio do Lago,et al.  An Oscillometric Detector for Capillary Electrophoresis , 1998 .

[24]  A. Zemann,et al.  Contactless conductivity detection for capillary electrophoresis. , 1998, Analytical chemistry.

[25]  Peter C Hauser,et al.  Effects of the cell geometry and operating parameters on the performance of an external contactless conductivity detector for microchip electrophoresis. , 2005, Lab on a chip.

[26]  S. Goldstein,et al.  Chemistry of peroxynitrites as compared to peroxynitrates. , 2005, Chemical reviews.

[27]  Andrew G Ewing,et al.  Dual fluorescence and electrochemical detection on an electrophoresis microchip. , 2002, Analytical chemistry.

[28]  S. Padmaja,et al.  The reaction of no with superoxide. , 1993, Free radical research communications.

[29]  A. Manz,et al.  Micro total analysis systems. Latest advancements and trends. , 2006, Analytical chemistry.

[30]  D. Bandyopadhyay,et al.  Oxidative stress-induced ischemic heart disease: protection by antioxidants. , 2004, Current medicinal chemistry.

[31]  A. Zemann Capacitively coupled contactless conductivity detection in capillary electrophoresis , 2003, Electrophoresis.

[32]  José Alberto Fracassi da Silva,et al.  Fabrication and integration of planar electrodes for contactless conductivity detection on polyester‐toner electrophoresis microchips , 2008, Electrophoresis.

[33]  W. Koppenol,et al.  Product distribution of peroxynitrite decay as a function of pH, temperature, and concentration. , 2002, Journal of the American Chemical Society.

[34]  H. Ischiropoulos,et al.  Oxidative stress and nitration in neurodegeneration: cause, effect, or association? , 2003, The Journal of clinical investigation.

[35]  P. Schmitt‐Kopplin,et al.  Quantitative and qualitative precision improvements by effective mobility‐scale data transformation in capillary electrophoresis analysis , 2001, Electrophoresis.

[36]  Martin Pumera,et al.  Contactless conductivity detector for microchip capillary electrophoresis. , 2002, Analytical chemistry.

[37]  Martin Pumera,et al.  Dual conductivity/amperometric detection system for microchip capillary electrophoresis. , 2002, Analytical chemistry.

[38]  A. Al-Mehdi,et al.  Peroxynitrite‐mediated oxidative protein modifications , 1995, FEBS letters.

[39]  Hizuru Nakajima,et al.  Detection method for microchip separations , 2004, Analytical and bioanalytical chemistry.

[40]  J. Beckman,et al.  Synthesis of peroxynitrite from nitrite and hydrogen peroxide. , 2005, Methods in enzymology.

[41]  J. Groves,et al.  Role for nitrosative stress in diabetic neuropathy: evidence from studies with a peroxynitrite decomposition catalyst , 2005, FASEB journal : official publication of the Federation of American Societies for Experimental Biology.

[42]  Claudimir L do Lago,et al.  Microfluidic devices obtained by thermal toner transferring on glass substrate , 2004, Electrophoresis.

[43]  T. Keng,et al.  Molecular Medicine © 2000 The Picower Institute Press Peroxynitrite Formation and Decreased Catalase Activity in Autoimmune MRL-lpr/lpr Mice , 2000 .