Improving Diagnostic Accuracy in Low-Dose SPECT Myocardial Perfusion Imaging With Convolutional Denoising Networks

Lowering the administered dose in SPECT myocardial perfusion imaging (MPI) has become an important clinical problem. In this study we investigate the potential benefit of applying a deep learning (DL) approach for suppressing the elevated imaging noise in low-dose SPECT-MPI studies. We adopt a supervised learning approach to train a neural network by using image pairs obtained from full-dose (target) and low-dose (input) acquisitions of the same patients. In the experiments, we made use of acquisitions from 1,052 subjects and demonstrated the approach for two commonly used reconstruction methods in clinical SPECT-MPI: 1) filtered backprojection (FBP), and 2) ordered-subsets expectation-maximization (OSEM) with corrections for attenuation, scatter and resolution. We evaluated the DL output for the clinical task of perfusion-defect detection at a number of successively reduced dose levels (1/2, 1/4, 1/8, 1/16 of full dose). The results indicate that the proposed DL approach can achieve substantial noise reduction and lead to improvement in the diagnostic accuracy of low-dose data. In particular, at 1/2 dose, DL yielded an area-under-the-ROC-curve (AUC) of 0.799, which is nearly identical to the AUC = 0.801 obtained by OSEM at full-dose ( ${p}$ -value = 0.73); similar results were also obtained for FBP reconstruction. Moreover, even at 1/8 dose, DL achieved AUC = 0.770 for OSEM, which is above the AUC = 0.755 obtained at full-dose by FBP. These results indicate that, compared to conventional reconstruction filtering, DL denoising can allow for additional dose reduction without sacrificing the diagnostic accuracy in SPECT-MPI.

[1]  Manojeet Bhattacharya,et al.  Dose reduction in half-time myocardial perfusion SPECT-CT with multifocal collimation , 2016, Journal of Nuclear Cardiology.

[2]  Mizuho Nishio,et al.  Convolutional auto-encoder for image denoising of ultra-low-dose CT , 2017, Heliyon.

[3]  Chuanyong Bai,et al.  A generalized model for the conversion from CT numbers to linear attenuation coefficients , 2002, 2002 IEEE Nuclear Science Symposium Conference Record.

[4]  A. Kelion,et al.  A qualitative and quantitative assessment of the impact of three processing algorithms with halving of study count statistics in myocardial perfusion imaging: filtered backprojection, maximal likelihood expectation maximisation and ordered subset expectation maximisation with resolution recovery , 2012, Journal of Nuclear Cardiology.

[5]  Hu Chen,et al.  Low-dose CT via convolutional neural network. , 2017, Biomedical optics express.

[6]  Michael Elad,et al.  Spatially-Adaptive Reconstruction in Computed Tomography Using Neural Networks , 2013, IEEE Transactions on Medical Imaging.

[7]  Feng Lin,et al.  Low-Dose CT With a Residual Encoder-Decoder Convolutional Neural Network , 2017, IEEE Transactions on Medical Imaging.

[8]  D. Broga,et al.  Ionizing Radiation Exposure of the Population of the United States , 2009 .

[9]  Giovanni Lucignani,et al.  Comparative analysis of full-time, half-time, and quarter-time myocardial ECG-gated SPECT quantification in normal-weight and overweight patients , 2017, Journal of Nuclear Cardiology.

[10]  E. Depuey,et al.  Wide beam reconstruction “quarter-time” gated myocardial perfusion SPECT functional imaging: a comparison to “full-time” ordered subset expectation maximum , 2009, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[11]  Yu-Bin Yang,et al.  Image Restoration Using Very Deep Convolutional Encoder-Decoder Networks with Symmetric Skip Connections , 2016, NIPS.

[12]  Michael Unser,et al.  Deep Convolutional Neural Network for Inverse Problems in Imaging , 2016, IEEE Transactions on Image Processing.

[13]  Albert Flotats,et al.  Current worldwide nuclear cardiology practices and radiation exposure: results from the 65 country IAEA Nuclear Cardiology Protocols Cross-Sectional Study (INCAPS) , 2015, European heart journal.

[14]  Michael A. King,et al.  Initial Investigation of Low-Dose SPECT-MPI via Deep Learning , 2018, 2018 IEEE Nuclear Science Symposium and Medical Imaging Conference Proceedings (NSS/MIC).

[15]  Piotr J Slomka,et al.  Investigation of dose reduction in cardiac perfusion SPECT via optimization and choice of the image reconstruction strategy , 2018, Journal of Nuclear Cardiology.

[16]  Guigang Zhang,et al.  Deep Learning , 2016, Int. J. Semantic Comput..

[17]  Jimmy Ba,et al.  Adam: A Method for Stochastic Optimization , 2014, ICLR.

[18]  T. Ruddy,et al.  Half-Time SPECT Myocardial Perfusion Imaging with Attenuation Correction , 2009, Journal of Nuclear Medicine.

[19]  George Shih,et al.  Hello World Deep Learning in Medical Imaging , 2018, Journal of Digital Imaging.

[20]  Xiaoou Tang,et al.  Image Super-Resolution Using Deep Convolutional Networks , 2014, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[21]  Razvan Pascanu,et al.  Understanding the exploding gradient problem , 2012, ArXiv.

[22]  B. Chaitman,et al.  Exercise Technetium‐99m Sestamibi Tomography for Cardiac Risk Stratification of Patients With Stable Chest Pain , 1994, Circulation.

[23]  Yoshua Bengio,et al.  Learning long-term dependencies with gradient descent is difficult , 1994, IEEE Trans. Neural Networks.

[24]  Xuanqin Mou,et al.  Low-Dose CT Image Denoising Using a Generative Adversarial Network With Wasserstein Distance and Perceptual Loss , 2017, IEEE Transactions on Medical Imaging.

[25]  Andrew J Einstein,et al.  ASNC imaging guidelines for SPECT nuclear cardiology procedures: Stress, protocols, and tracers , 2016, Journal of Nuclear Cardiology.

[26]  D. Francis,et al.  Mortality from ischaemic heart disease by country, region, and age: Statistics from World Health Organisation and United Nations , 2013, International journal of cardiology.

[27]  Simon R. Cherry,et al.  Machine Learning in PET: From Photon Detection to Quantitative Image Reconstruction , 2020, Proceedings of the IEEE.

[28]  Guido Germano,et al.  Comparison of Fully Automated Computer Analysis and Visual Scoring for Detection of Coronary Artery Disease from Myocardial Perfusion SPECT in a Large Population , 2013, The Journal of Nuclear Medicine.

[29]  Max A. Viergever,et al.  Generative Adversarial Networks for Noise Reduction in Low-Dose CT , 2017, IEEE Transactions on Medical Imaging.

[30]  Hongming Shan,et al.  3-D Convolutional Encoder-Decoder Network for Low-Dose CT via Transfer Learning From a 2-D Trained Network , 2018, IEEE Transactions on Medical Imaging.

[31]  Sergey Ioffe,et al.  Batch Normalization: Accelerating Deep Network Training by Reducing Internal Covariate Shift , 2015, ICML.

[32]  Håkan Arheden,et al.  The radiation dose to overweighted patients undergoing myocardial perfusion SPECT can be significantly reduced: validation of a linear weight-adjusted activity administration protocol , 2017, Journal of Nuclear Cardiology.

[33]  D. Berman,et al.  Automated quantification of myocardial perfusion SPECT using simplified normal limits , 2004, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[34]  Tao Tan,et al.  Denoising of 3D magnetic resonance images with multi-channel residual learning of convolutional neural network , 2017, Japanese Journal of Radiology.

[35]  Michael A. King,et al.  Personalized Models for Injected Activity Levels in SPECT Myocardial Perfusion Imaging , 2019, IEEE Transactions on Medical Imaging.

[36]  Leslee J Shaw,et al.  Nationwide Laboratory Adherence to Myocardial Perfusion Imaging Radiation Dose Reduction Practices: A Report From the Intersocietal Accreditation Commission Data Repository. , 2015, JACC. Cardiovascular imaging.

[37]  Chih-Chieh Liu,et al.  PET Image Denoising Using a Deep Neural Network Through Fine Tuning , 2019, IEEE Transactions on Radiation and Plasma Medical Sciences.

[38]  D. Brenner,et al.  Computed tomography--an increasing source of radiation exposure. , 2007, The New England journal of medicine.

[39]  Michael A. King,et al.  Evaluation of the effect of reducing administered activity on assessment of function in cardiac gated SPECT , 2018, Journal of Nuclear Cardiology.

[40]  Lei Zhang,et al.  Beyond a Gaussian Denoiser: Residual Learning of Deep CNN for Image Denoising , 2016, IEEE Transactions on Image Processing.

[41]  Lipo Wang,et al.  Deep Learning Applications in Medical Image Analysis , 2018, IEEE Access.

[42]  D. Kitzman,et al.  Role of myocardial perfusion imaging for risk stratification in suspected or known coronary artery disease , 2003, Heart.

[43]  R. Glenn Wells,et al.  Dose reduction is good but it is image quality that matters , 2018, Journal of Nuclear Cardiology.

[44]  Yoshua Bengio,et al.  Extracting and composing robust features with denoising autoencoders , 2008, ICML '08.

[45]  James S. Duncan,et al.  Biomedical Imaging and Analysis in the Age of Big Data and Deep Learning , 2020, Proc. IEEE.

[46]  K. Ogawa,et al.  A practical method for position-dependent Compton-scatter correction in single photon emission CT. , 1991, IEEE transactions on medical imaging.