EEG acquisition system based on active electrodes with common-mode interference suppression by Driving Right Leg circuit

We present a system for the acquisition of EEG signals based on active electrodes and implementing a Driving Right Leg circuit (DgRL). DgRL allows for single-ended amplification and analog-to-digital conversion, still guaranteeing a common mode rejection in excess of 110 dB. This allows the system to acquire high-quality EEG signals essentially removing network interference for both wet and dry-contact electrodes. The front-end amplification stage is integrated on the electrode, minimizing the system's sensitivity to electrode contact quality, cable movement and common mode interference. The A/D conversion stage can be either integrated in the remote back-end or placed on the head as well, allowing for an all-digital communication to the back-end. Noise integrated in the band from 0.5 to 100 Hz is comprised between 0.62 and 1.3 μV, depending on the configuration. Current consumption for the amplification and A/D conversion of one channel is 390 μA. Thanks to its low noise, the high level of interference suppression and its quick setup capabilities, the system is particularly suitable for use outside clinical environments, such as in home care, brain-computer interfaces or consumer-oriented applications.

[1]  Refet Firat Yazicioglu,et al.  A 160μW 8-channel active electrode system for EEG monitoring , 2011, 2011 IEEE International Solid-State Circuits Conference.

[2]  G. Cauwenberghs,et al.  Micropower non-contact EEG electrode with active common-mode noise suppression and input capacitance cancellation , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[3]  Refet Firat Yazicioglu,et al.  A $160~\mu {\rm W}$ 8-Channel Active Electrode System for EEG Monitoring , 2011, IEEE Transactions on Biomedical Circuits and Systems.

[4]  Roberto Guerrieri,et al.  A Driving Right Leg Circuit (DgRL) for Improved Common Mode Rejection in Bio-Potential Acquisition Systems , 2016, IEEE Transactions on Biomedical Circuits and Systems.

[5]  G. Comi,et al.  IFCN standards for digital recording of clinical EEG. International Federation of Clinical Neurophysiology. , 1998, Electroencephalography and clinical neurophysiology.

[6]  Roberto Guerrieri,et al.  Active Electrode IC for EEG and Electrical Impedance Tomography With Continuous Monitoring of Contact Impedance , 2015, IEEE Transactions on Biomedical Circuits and Systems.

[7]  John G. Webster,et al.  Driven-right-leg circuit design , 1983, IEEE Transactions on Biomedical Engineering.

[8]  Tzyy-Ping Jung,et al.  Dry-Contact and Noncontact Biopotential Electrodes: Methodological Review , 2010, IEEE Reviews in Biomedical Engineering.