Bayesian estimation of relaxation times T(1) in MR images of irradiated Fricke-agarose gels.

The authors present a novel method for processing T(1)-weighted images acquired with Inversion-Recovery (IR) sequence. The method, developed within the Bayesian framework, takes into account a priori knowledge about the spatial regularity of the parameters to be estimated. Inference is drawn by means of Markov Chains Monte Carlo algorithms. The method has been applied to the processing of IR images from irradiated Fricke-agarose gels, proposed in the past as relative dosimeter to verify radiotherapeutic treatment planning systems. Comparison with results obtained from a standard approach shows that signal-to noise ratio (SNR) is strongly enhanced when the estimation of the longitudinal relaxation rate (R1) is performed with the newly proposed statistical approach. Furthermore, the method allows the use of more complex models of the signal. Finally, an appreciable reduction of total acquisition time can be obtained due to the possibility of using a reduced number of images. The method can also be applied to T(1) mapping of other systems.

[1]  M G Lötter,et al.  Chelator effect on ion diffusion in ferrous-sulfate-doped gelatin gel dosimeters as analyzed by MRI. , 1996, Medical physics.

[2]  Xavier Descombes,et al.  Spatio-temporal fMRI analysis using Markov random fields , 1998, IEEE Transactions on Medical Imaging.

[3]  Ingrid K. Glad,et al.  A Bayesian approach to synthetic magnetic resonance imaging , 1995 .

[4]  E. Raman,et al.  Parameter estimation from magnitude MR images , 1999 .

[5]  M. Alley,et al.  Differentiation between the effects of T1 and T2* shortening in contrast‐enhanced MRI of the breast , 1999, Journal of magnetic resonance imaging : JMRI.

[6]  Francesco D'errico,et al.  MR images of Fricke-agarose dosimeters irradiated with proton beams , 1999 .

[7]  R. Henkelman Measurement of signal intensities in the presence of noise in MR images. , 1985, Medical physics.

[8]  L E Olsson,et al.  MR imaging of absorbed dose distributions for radiotherapy using ferrous sulphate gels. , 1990, Physics in medicine and biology.

[9]  M A Moerland,et al.  Numerical analysis of the magnetic field for arbitrary magnetic susceptibility distributions in 3D. , 1994, Magnetic resonance imaging.

[10]  Sylvia Richardson,et al.  Markov Chain Monte Carlo in Practice , 1997 .

[11]  David H. Laidlaw,et al.  Partial-volume Bayesian classification of material mixtures in MR volume data using voxel histograms , 1997, IEEE Transactions on Medical Imaging.

[12]  Simon J. Godsill,et al.  Bayesian methods in signal and image processing , 1999 .

[13]  S. Bäck Implementation of MRI gel dosimetry in radiation therapy , 1998 .

[14]  William H. Press,et al.  Numerical Recipes: FORTRAN , 1988 .

[15]  P. Narayana,et al.  Accuracy and Reproducibility in Volumetric Analysis of Multiple Sclerosis Lesions , 1993, Journal of computer assisted tomography.

[16]  Y. Amit Graphical shape templates for automatic anatomy detection with applications to MRI brain scans , 1997, IEEE Transactions on Medical Imaging.

[17]  F D'Errico,et al.  Dose distribution of proton beams with NMR measurements of Fricke-agarose gels. , 1997, Magnetic resonance imaging.

[18]  Gerhard Winkler,et al.  Image analysis, random fields and dynamic Monte Carlo methods: a mathematical introduction , 1995, Applications of mathematics.

[19]  Piero Barone,et al.  Truncation artifact reduction in magnetic resonance imaging by Markov random field methods , 1995, IEEE Trans. Medical Imaging.

[20]  C. Hardy,et al.  A review of 1H nuclear magnetic resonance relaxation in pathology: are T1 and T2 diagnostic? , 1987, Medical physics.

[21]  J. Buatti,et al.  Image registration of BANG gel dose maps for quantitative dosimetry verification. , 1999, International journal of radiation oncology, biology, physics.

[22]  Stuart Geman,et al.  Statistical methods for tomographic image reconstruction , 1987 .

[23]  N. Metropolis,et al.  Equation of State Calculations by Fast Computing Machines , 1953, Resonance.

[24]  J C Gore,et al.  Radiation therapy dosimetry using magnetic resonance imaging of polymer gels. , 1996, Medical physics.

[25]  S. Reeder,et al.  Blood oxygenation dependence of t1 and t2 in the isolated, perfused rabbit heart at 4.7t , 1995, Magnetic resonance in medicine.

[26]  N. J. Herrod,et al.  Materials mapped with NMR , 1991 .

[27]  Fred Godtliebsen,et al.  On the use of Gibbs priors for Bayesian image restoration , 1997, Signal Process..