Accuracy of Pedicle Screw Placement with Robotic Guidance System: A Cadaveric Study

Study Design. A cadaveric study. Objective. To investigate the accuracy of pedicle screw placement using a robotic guidance system (RGS). Summary of Background Data. RGS is a unique surgery assistance-apparatus. Although several clinical studies have demonstrated that RGS provides accurate pedicle screw placement, very few studies have validated its accuracy. Methods. A total of 216 trajectories performed with the assistance of the RGS in eight cadavers were evaluated. The RGS was used, with different mounting platforms, to drill pilot holes in the thoracic and lumbosacral spine, using 3-mm diameter fiducial wires as trajectory markers. Deviation between the preoperative plan and executed trajectories was measured at the entry points to the vertebrae and at a depth of 30 mm along the wire. Both the deviation from the preoperative plan and the wire position were evaluated in the axial and sagittal planes using computed tomography (CT). Results. The average deviation from the planned wire placement was 0.64 ± 0.59 mm at the entry point and 0.63 ± 0.57 mm at a depth of 30 mm in the axial plane, and 0.77 ± 0.62 mm and 0.80 ± 0.66 mm, respectively, in the sagittal plane. The magnitude of deviation was not affected by the vertebral level or the platform used. The use of an open approach achieved greater screw placement accuracy at a depth of 30 mm in the sagittal plane, compared with the percutaneous approach. The fiducials were placed completely within the pedicle in 93.9% of trajectories in the axial plane (n = 164 pedicles with a width ≥5 mm) and 98.6% in the sagittal plane (n = 216). Conclusion. In this cadaveric study, RGS supported execution of accurate trajectories that were equal or slightly superior to reports of CT-based navigation systems. Level of Evidence: N/A

[1]  W. Sukovich,et al.  Miniature robotic guidance for pedicle screw placement in posterior spinal fusion: early clinical experience with the SpineAssist® , 2006, The international journal of medical robotics + computer assisted surgery : MRCAS.

[2]  J. R. Landis,et al.  The measurement of observer agreement for categorical data. , 1977, Biometrics.

[3]  M. Hardenbrook,et al.  Assessment of Pedicle Screw Placement Accuracy, Procedure Time, and Radiation Exposure Using a Miniature Robotic Guidance System , 2012, Journal of spinal disorders & techniques.

[4]  W. Rüther,et al.  Anatomic evaluation of two different techniques for the percutaneous insertion of pedicle screws in the lumbar spine. , 1999, Spine.

[5]  R. Winter,et al.  Complications associated with pedicle screws. , 1999, The Journal of bone and joint surgery. American volume.

[6]  K. Takaoka,et al.  Accurate pedicle screw insertion under the control of a computer-assisted image guiding system: Laboratory test and clinical study , 1999, Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association.

[7]  G. Deuretzbacher,et al.  Computer Navigation of Parapedicular Screw Fixation in the Thoracic Spine: A Cadaver Study , 2001, Spine.

[8]  Kevin T. Foley,et al.  Minimally invasive pedicle screw fixation utilizing O-arm fluoroscopy with computer-assisted navigation: Feasibility, technique, and preliminary results , 2010, Surgical neurology international.

[9]  S. C. Açıkbaş,et al.  The effect of transpedicular screw misplacement on late spinal stability , 2003, Acta Neurochirurgica.

[10]  K. Vosburgh,et al.  In vivo pedicle screw placement: image-guided virtual vision. , 2000, Journal of spinal disorders.

[11]  M. Hardenbrook,et al.  Clinical Acceptance and Accuracy Assessment of Spinal Implants Guided With SpineAssist Surgical Robot: Retrospective Study , 2010, Spine.

[12]  H. Hashidate,et al.  Accuracy of Multilevel Registration in Image-Guided Pedicle Screw Insertion for Adolescent Idiopathic Scoliosis , 2010, Spine.

[13]  F. Langlotz,et al.  Clinical evaluation of a system for precision enhancement in spine surgery. , 1995, Clinical biomechanics.

[14]  A. Jayaswal,et al.  Outcome-Based Classification for Assessment of Thoracic Pedicular Screw Placement , 2008, Spine.

[15]  Richard Assaker,et al.  Transpedicular Screw Placement: Image-Guided Versus Lateral-View Fluoroscopy:In Vitro Simulation , 2001, Spine.

[16]  J H Kim,et al.  Thoracic Pedicle Screw Fixation in Spinal Deformities: Are They Really Safe? , 2001, Spine.

[17]  H. An,et al.  Placement of pedicle screws in the thoracic spine. Part I: Morphometric analysis of the thoracic vertebrae. , 1995, The Journal of bone and joint surgery. American volume.

[18]  M. M. Panjabi,et al.  Complexity of the thoracic spine pedicle anatomy , 2005, European Spine Journal.

[19]  V. Rohde,et al.  Perioperative course and accuracy of screw positioning in conventional, open robotic-guided and percutaneous robotic-guided, pedicle screw placement , 2011, European Spine Journal.

[20]  F. Auer,et al.  Accuracy of Robot-Assisted Placement of Lumbar and Sacral Pedicle Screws: A Prospective Randomized Comparison to Conventional Freehand Screw Implantation , 2012, Spine.

[21]  K. Takaoka,et al.  Cervical pedicle screw insertion: assessment of safety and accuracy with computer-assisted image guidance. , 2000, Journal of spinal disorders.

[22]  F. Langlotz,et al.  Accuracy of Computer‐Assisted Pedicle Screw Placement: An In Vivo Computed Tomography Analysis , 1997, Spine.

[23]  S Vidyadhara,et al.  Randomized Clinical Study to Compare the Accuracy of Navigated and Non-Navigated Thoracic Pedicle Screws in Deformity Correction Surgeries , 2007, Spine.

[24]  Y Barzilay,et al.  Miniature robotic guidance for spine surgery — introduction of a novel system and analysis of challenges encountered during the clinical development phase at two spine centres , 2006, The international journal of medical robotics + computer assisted surgery : MRCAS.

[25]  Kirsten Schmieder,et al.  Percutaneous Placement of Pedicle Screws in the Lumbar Spine Using a Bone Mounted Miniature Robotic System: First Experiences and Accuracy of Screw Placement , 2009, Spine.

[26]  J. Mac-Thiong,et al.  Neurological Outcome and Management of Pedicle Screws Misplaced Totally Within the Spinal Canal , 2013, Spine.

[27]  Constantin Schizas,et al.  Pedicle Screw Placement Accuracy: A Meta-analysis , 2007, Spine.

[28]  Alon Wolf,et al.  Feasibility Study of a Mini, Bone-Attached, Robotic System for Spinal Operations: Analysis and Experiments , 2004, Spine.

[29]  Dominik Morhard,et al.  Intraoperative Computed Tomography With Integrated Navigation System in Spinal Stabilizations , 2009, Spine.

[30]  Constantin Schizas,et al.  Computer tomography assessment of pedicle screw insertion in percutaneous posterior transpedicular stabilization , 2007, European Spine Journal.

[31]  Bong-Soon Chang,et al.  Monitoring the Quality of Robot-Assisted Pedicle Screw Fixation in the Lumbar Spine by Using a Cumulative Summation Test , 2015, Spine.

[32]  S. Gertzbein,et al.  Accuracy of Pedicular Screw Placement In Vivo , 1990, Spine.

[33]  W. Castro,et al.  Accuracy of Pedicle Screw Placement in Lumbar Vertebrae , 1996, Spine.

[34]  M. Shoham,et al.  BONE‐MOUNTED MINIATURE ROBOTIC GUIDANCE FOR PEDICLE SCREW AND TRANSLAMINAR FACET SCREW PLACEMENT: PART 2—EVALUATION OF SYSTEM ACCURACY , 2007, Neurosurgery.

[35]  I. Lieberman,et al.  Robotic-assisted pedicle screw placement: lessons learned from the first 102 patients , 2013, European Spine Journal.

[36]  F. Cammisa,et al.  The placement of lumbar pedicle screws using computerised stereotactic guidance. , 1999, The Journal of bone and joint surgery. British volume.

[37]  T. Witham,et al.  Incidence and Clinical Significance of Vascular Encroachment Resulting From Freehand Placement of Pedicle Screws in the Thoracic and Lumbar Spine: Analysis of 6816 Consecutive Screws , 2014, Spine.

[38]  Ping Zhou,et al.  Pedicle screw insertion accuracy with different assisted methods: a systematic review and meta-analysis of comparative studies , 2011, European Spine Journal.

[39]  Vincent Arlet,et al.  Complications of Pedicle Screw Fixation in Scoliosis Surgery: A Systematic Review , 2010, Spine.

[40]  K. White,et al.  Pullout Strength of Thoracic Pedicle Screw Instrumentation: Comparison of the Transpedicular and Extrapedicular Techniques , 2006, Spine.

[41]  Ahmed A. Aoude,et al.  Methods to determine pedicle screw placement accuracy in spine surgery: a systematic review , 2015, European Spine Journal.

[42]  Robert F Spetzler,et al.  Intraoperative Iso-C C-Arm Navigation in Craniospinal Surgery: The First 60 Cases , 2004, Neurosurgery.