Behavior of capillary valves in centrifugal microfluidic devices prepared by three-dimensional printing

This paper details the behavior of capillary valves in centrifugal microfluidic devices prepared by three-dimensional (3D), or solid-object, printing. Microfluidic structures containing valve channels with different widths, heights, and radial distances from the center of rotation were studied and compared with extant capillary valve theories. Due to the printing process, the produced valve channels possessed a ridged or “scalloped” pattern. Hence, actual channel widths at the widest and narrowest points of the ridged pattern were determined, and used in comparisons between theoretical and empirical values. In addition, variations in contact angle resulting from the ridged pattern were measured and employed in theoretical calculations. For 1-mm high valve channels, the critical angular frequency (rpm) required to overcome capillary valve pressure was found to be independent of width. However, as the height of the valve channel was reduced, the critical rpm was found to become progressively more width-dependent increasing more rapidly for narrower channels. Both of these observations point to a role for feature sharpness, as well as the geometry of the valve channel opening, in valve behavior. Otherwise, valves followed a predictable trend of increasing critical rpm with decreased valve height and decreased radial distance from the rotation center. Using these results as a guide, then, it is possible to prepare centrifugal microfluidic devices by 3D printing with operability comparable to devices prepared by other microfabrication techniques.

[1]  Jerry M Chen,et al.  Analysis and experiment of capillary valves for microfluidics on a rotating disk , 2008 .

[2]  J. Vacanti,et al.  Toward regenerating a human thumb in situ. , 2009, Tissue engineering. Part A.

[3]  Roland Zengerle,et al.  The centrifugal microfluidic Bio-Disk platform , 2007 .

[4]  M. Burns,et al.  Microfabricated capillarity-driven stop valve and sample injector , 1998, Proceedings MEMS 98. IEEE. Eleventh Annual International Workshop on Micro Electro Mechanical Systems. An Investigation of Micro Structures, Sensors, Actuators, Machines and Systems (Cat. No.98CH36176.

[5]  Marc Madou,et al.  Lab on a CD. , 2006, Annual review of biomedical engineering.

[6]  George M Whitesides,et al.  Prototyping of microfluidic devices in poly(dimethylsiloxane) using solid-object printing. , 2002, Analytical chemistry.

[7]  Jintae Kim,et al.  Centrifugal microfluidics for biomedical applications. , 2010, Lab on a chip.

[8]  Sylvia Daunert,et al.  Integration of microcolumns and microfluidic fractionators on multitasking centrifugal microfluidic platforms for the analysis of biomolecules , 2006, Analytical and bioanalytical chemistry.

[9]  Shu Yang,et al.  Tunable open-channel microfluidics on soft poly(dimethylsiloxane) (PDMS) substrates with sinusoidal grooves. , 2009, Langmuir : the ACS journal of surfaces and colloids.

[10]  Microfiber assisted fabrication of microfluidic channels using poly(dimethylsiloxane) , 2003 .

[11]  J. Kang,et al.  How the capillary burst microvalve works. , 2007, Journal of colloid and interface science.

[12]  Bruce K Gale,et al.  Spinning disk platform for microfluidic digital polymerase chain reaction. , 2010, Analytical chemistry.

[13]  Manish Deshpande,et al.  Design Analyses of Capillary Burst Valves in Centrifugal Microfluidics , 2000 .

[14]  P. Malanowski,et al.  Chemical and structural changes at the ABS polymer-copper metal interface , 2007 .

[15]  R. P. Keatch,et al.  Characterisation of rapid prototyping techniques for studies in cell behaviour , 2010 .

[16]  Yoon‐Kyoung Cho,et al.  A fully automated immunoassay from whole blood on a disc. , 2009, Lab on a chip.

[17]  Roland Zengerle,et al.  Centrifugo-pneumatic valve for metering of highly wetting liquids on centrifugal microfluidic platforms. , 2009, Lab on a chip.

[18]  M. R. Griffin,et al.  Microgravity Manufacturing Via Fused Deposition , 2003 .

[19]  Roger H. Rangel,et al.  Passive flow switching valves on a centrifugal microfluidic platform , 2008 .

[20]  M. Madou,et al.  Development of a fully integrated analysis system for ions based on ion-selective optodes and centrifugal microfluidics. , 2001, Analytical chemistry.

[21]  M. Madou,et al.  Fluorescent ion-selective optode membranes incorporated onto a centrifugal microfluidics platform. , 2002, Analytical chemistry.

[22]  R. Zengerle,et al.  Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications. , 2010, Chemical Society reviews.

[23]  Joe T. Lin,et al.  Microfabricated Centrifugal Microfluidic Systems: Characterization and Multiple Enzymatic Assays , 1999 .

[24]  Sylvia Daunert,et al.  Microfluidic ion-sensing devices. , 2008, Analytica chimica acta.

[25]  Qiang Zhao,et al.  Enhancement of mesenchymal stem cell attachment to decellularized porcine aortic valve scaffold by in vitro coating with antibody against CD90: a preliminary study on antibody-modified tissue-engineered heart valve. , 2009, Tissue engineering. Part A.