Comparison of fit accuracy between Procera® custom abutments and three implant systems.

BACKGROUND Although increase of misfit has been reported when associating implant and abutment from different manufacturers, Procera custom abutment has been universally used in clinical practice. PURPOSE The purpose of this investigation was to compare the vertical gap of zirconia Procera® abutment associated with implants from the same manufacturer (Procera manufacturer) and two other implant systems. MATERIALS AND METHODS Twenty-four zirconia Procera abutments were produced using computer-assisted design and manufacture and paired with (a) eight MK III, RP 4.1 × 10 mm implants (Nobel Biocare™, Göteborg, Sweden) - GNB group (Nobel Biocare group); (b) eight Try on, 4.1 × 10 mm implants (Sistema de Implantes, São Paulo, Brazil) - ES group (SIN experimental group) ; and (c) eight Master screw, 4.1 × 10 mm implants (Conexão® Sistema de Prótese, São Paulo, Brazil) - EC group (Conexão experimental group). A comparison of the vertical misfit at the implant-abutment interface was taken at six measuring sites on each sample using scanning electron microscopy with a magnification of 408×. One-way analysis of variance was used to test for differences, and Tukey's test was used for pair-wise comparison of groups (α = 0.05). RESULTS Significant differences relative to average misfit were found when Procera abutments were associated with other implant manufacturers. The ES group and EC group did not differ significantly, but both demonstrated significantly larger average misfit than the GNB group (p = .001). The average misfit was 5.7 µm ± 0.39, 9.53 µm ± 0.52, and 10.62 µm ± 2.16, respectively, for groups GNB, ES, and EC. CONCLUSION The association of Procera zirconia abutment with other implant systems different from its manufacturer demonstrated significant alteration of vertical misfit at implant-abutment interface.

[1]  Chun-Li Lin,et al.  Factorial analysis of variables influencing mechanical characteristics of a single tooth implant placed in the maxilla using finite element analysis and the statistics-based Taguchi method. , 2007, European journal of oral sciences.

[2]  P G Coelho,et al.  Cross-sectional analysis of the implant-abutment interface. , 2007, Journal of oral rehabilitation.

[3]  Roberto Adrian Markarian,et al.  Stress distribution after installation of fixed frameworks with marginal gaps over angled and parallel implants: a photoelastic analysis. , 2007, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[4]  B. Kucey,et al.  The Procera abutment--the fifth generation abutment for dental implants. , 2000, Journal.

[5]  Noel Claffey,et al.  Preloads generated with repeated tightening in three types of screws used in dental implant assemblies. , 2006, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[6]  D Edelhoff,et al.  Ceramic abutments--a new era in achieving optimal esthetics in implant dentistry. , 2000, The International journal of periodontics & restorative dentistry.

[7]  V. Barão,et al.  Effect of Superstructure Materials and Misfit on Stress Distribution in a Single Implant-Supported Prosthesis: A Finite Element Analysis , 2010, The Journal of craniofacial surgery.

[8]  Bülent Ekici,et al.  Influence of occlusal forces on stress distribution in preloaded dental implant screws. , 2004, The Journal of prosthetic dentistry.

[9]  W Becker,et al.  Replacement of maxillary and mandibular molars with single endosseous implant restorations: a retrospective study. , 1995, The Journal of prosthetic dentistry.

[10]  A. Barone,et al.  Bacterial Plaque Colonization Around Dental Implant Surfaces , 2006, Implant dentistry.

[11]  Cheng-Kung Cheng,et al.  Influence of off-axis loading of an anterior maxillary implant: a 3-dimensional finite element analysis. , 2007, The International journal of oral & maxillofacial implants.

[12]  T Jemt,et al.  Failures and complications in 127 consecutively placed fixed partial prostheses supported by Brånemark implants: from prosthetic treatment to first annual checkup. , 1992, The International journal of oral & maxillofacial implants.

[13]  Mehmet Avci,et al.  The implant-abutment interface of alumina and zirconia abutments. , 2008, Clinical implant dentistry and related research.

[14]  A B Carr,et al.  The response of bone in primates around unloaded dental implants supporting prostheses with different levels of fit. , 1996, The Journal of prosthetic dentistry.

[15]  T Jemt,et al.  Prosthesis misfit and marginal bone loss in edentulous implant patients. , 1996, The International journal of oral & maxillofacial implants.

[16]  A. Piattelli,et al.  Role of the microgap between implant and abutment: a retrospective histologic evaluation in monkeys. , 2003, Journal of periodontology.

[17]  M. Quirynen,et al.  Bacterial colonization of the internal part of two-stage implants. An in vivo study. , 1993, Clinical oral implants research.

[18]  E. Richter,et al.  Microbial leakage and marginal fit of the implant-abutment interface. , 1997, The International journal of oral & maxillofacial implants.

[19]  S A Aquilino,et al.  Micromotion and dynamic fatigue properties of the dental implant-abutment interface. , 2001, The Journal of prosthetic dentistry.

[20]  R. L. Simon,et al.  Single implant-supported molar and premolar crowns: a ten-year retrospective clinical report. , 2003, The Journal of prosthetic dentistry.

[21]  U. Lekholm,et al.  Bone response to implant-supported frameworks with differing degrees of misfit preload: in vivo study in rabbits. , 2000, Clinical implant dentistry and related research.

[22]  F Houston,et al.  The fit of cast and premachined implant abutments. , 1998, The Journal of prosthetic dentistry.

[23]  D van Steenberghe,et al.  Microbial penetration along the implant components of the Brånemark system. An in vitro study. , 1994, Clinical oral implants research.

[24]  Steven E Eckert,et al.  Cyclic loading of implant-supported prostheses: comparison of gaps at the prosthetic-abutment interface when cycled abutments are replaced with as-manufactured abutments. , 2006, The Journal of prosthetic dentistry.

[25]  D Buser,et al.  Influence of the size of the microgap on crestal bone changes around titanium implants. A histometric evaluation of unloaded non-submerged implants in the canine mandible. , 2001, Journal of periodontology.

[26]  G. Romanos,et al.  Peri-implant bone reactions to immediately loaded implants. An experimental study in monkeys. , 2001, Journal of periodontology.

[27]  Z M Isa,et al.  The effects of superstructure fit and loading on individual implant units: Part I. The effects of tightening the gold screws and placement of a superstructure with varying degrees of fit. , 1993, The European journal of prosthodontics and restorative dentistry.

[28]  Marianella Sierraalta,et al.  Evaluation of the precision of fit between the Procera custom abutment and various implant systems. , 2003, The International journal of oral & maxillofacial implants.