Fiber Bragg Grating Measuring System for Simultaneous Monitoring of Temperature and Humidity in Mechanical Ventilation

During mechanical ventilation, the humidification of the dry air delivered by the mechanical ventilator is recommended. Among several solutions, heated wire humidifiers (HWHs) have gained large acceptance to be used in this field. The aim of this work is to fabricate a measuring system based on fiber Bragg grating (FBG) for the simultaneous monitoring of gas relative humidity (RH) and temperature, intended to be used for providing feedback to the HWHs’ control. This solution can be implemented using an array of two FBGs having a different center wavelength. Regarding RH monitoring, three sensors have been fabricated by coating an FBG with two different moisture-sensitive and biocompatible materials: the first two sensors were fabricated by coating the grating with a 3 mm × 3 mm layer of agar and agarose; to investigate the influence of the coating thickness to the sensor response, a third sensor was developed with a 5 mm × 5 mm layer of agar. The sensors have been assessed in a wide range of RH (up to 95%) during both an ascending and a subsequent descending phase. Only the response of the 3 mm × 3 mm-coated sensors were fast enough to follow the RH changes, showing a mean sensitivity of about 0.14 nm/% (agar-coated) and 0.12 nm/% (agarose-coated). The hysteresis error was about <10% in the two sensors. The contribution of temperature changes on these RH sensors was negligible. The temperature measurement was performed by a commercial FBG insensitive to RH changes. The small size of these FBG-based sensors, the use of biocompatible polymers, and the possibility to measure both temperature and RH by using the same fiber optic embedding an array of two FBGs make intriguing the use of this solution for application in the control of HWHs.

[1]  Paulo S. André,et al.  Optical Fiber Relative Humidity Sensor Based on a FBG with a Di-Ureasil Coating , 2012, Sensors.

[2]  Sailing He,et al.  An open-cavity Fabry-Perot interferometer with PVA coating for simultaneous measurement of relative humidity and temperature , 2016 .

[3]  E Schena,et al.  A novel control strategy to improve the performances of heated wire humidifiers in artificial neonatal ventilation. , 2012, Physiological measurement.

[4]  F. Arregui,et al.  Optical fiber humidity sensor based on a tapered fiber coated with agarose gel , 2000 .

[5]  Y. Gong,et al.  Polyimide-coated fiber Bragg grating for relative humidity sensing , 2015 .

[6]  Ruben D Restrepo,et al.  Humidification During Invasive and Noninvasive Mechanical Ventilation: 2012 , 2012, Respiratory Care.

[7]  E. John,et al.  Inspired gas humidity during mechanical ventilation: Effects of humidification chamber, airway temperature probe position and environmental conditions , 2001, Journal of Paediatrics and Child Health.

[8]  T Mashimo,et al.  Performance of heated humidifiers with a heated wire according to ventilatory settings. , 2001, Journal of aerosol medicine : the official journal of the International Society for Aerosols in Medicine.

[9]  T. L. Yeo,et al.  Fibre-optic sensor technologies for humidity and moisture measurement , 2008 .

[10]  Richard O. Claus,et al.  Simultaneous measurement of humidity and temperature by combining a reflective intensity-based optical fiber sensor and a fiber Bragg grating , 2002 .

[11]  Kaiming Zhou,et al.  Toward a New Generation of Photonic Humidity Sensors , 2014, Sensors.

[12]  W. Yaphe,et al.  The structure of agar : Part I. Fractionation of a complex mixture of polysaccharides , 1971 .

[13]  J. L. Santos,et al.  Simultaneous Measurement of Humidity and Temperature Based on an SiO$_{2}$ -Nanospheres Film Deposited on a Long-Period Grating In-Line With a Fiber Bragg Grating , 2011, IEEE Sensors Journal.

[14]  Umesh Tiwari,et al.  Fiber grating sensors in medicine: Current and emerging applications , 2011 .

[15]  Ned Djilali,et al.  Parametric study of a polymer-coated fibre-optic humidity sensor , 2012 .

[16]  Xueguang Qiao,et al.  An Optical Fiber Fabry–Perot Interferometer Sensor for Simultaneous Measurement of Relative Humidity and Temperature , 2014, IEEE Sensors Journal.

[17]  Kai Ni,et al.  Simultaneous Measurement of Humidity and Temperature Based on a Long-Period Fiber Grating Inscribed in Fiber Loop Mirror , 2014, IEEE Sensors Journal.

[18]  T. Erdogan Fiber grating spectra , 1997 .

[19]  D. Galler,et al.  Relationship between the humidity and temperature of inspired gas and the function of the airway mucosa. , 1996, Critical care medicine.

[20]  Tong Sun,et al.  Polymer-coated fiber Bragg grating for relative humidity sensing , 2005, IEEE Sensors Journal.

[21]  Peng Zu,et al.  Humidity Sensor Based on a Multimode-Fiber Taper Coated With Polyvinyl Alcohol Interacting With a Fiber Bragg Grating , 2012, IEEE Sensors Journal.

[22]  Salvador Sales,et al.  Simultaneous measurement of humidity and temperature based on a partially coated optical fiber long period grating , 2016 .

[23]  Emiliano Schena,et al.  Flow measurement in mechanical ventilation: a review. , 2015, Medical engineering & physics.

[24]  L. Alwis,et al.  Analysis of Polyimide-Coated Optical Fiber Long-Period Grating-Based Relative Humidity Sensor , 2013, IEEE Sensors Journal.

[25]  Kefa Cen,et al.  Low-cost relative humidity sensor based on thermoplastic polyimide-coated fiber Bragg grating , 2007 .

[26]  P. Pelosi,et al.  In vitro and in vivo evaluation of a new active heat moisture exchanger , 2004, Critical care.

[27]  Gang-Ding Peng,et al.  Optical fibre temperature and humidity sensor , 2010 .

[28]  Fauzan Ahmad,et al.  Study of a fiber optic humidity sensor based on agarose gel , 2014 .

[29]  Bo Liu,et al.  Agarose gel-coated LPG based on two sensing mechanisms for relative humidity measurement. , 2013, Applied optics.

[30]  Sergio Silvestri,et al.  Mathematical model and minimal measurement system for optimal control of heated humidifiers in neonatal ventilation. , 2010, Medical engineering & physics.

[31]  R. P. Tatam,et al.  Multi-parameter measurements using optical fibre long period gratings for indoor air quality monitoring , 2017, 2017 25th Optical Fiber Sensors Conference (OFS).

[32]  B. Yadav,et al.  Opto-electronic humidity sensor: A review , 2015 .

[33]  G. Smaldone,et al.  Y-piece temperature and humidification during mechanical ventilation. , 2009, Respiratory care.

[34]  S. James,et al.  Optical fibre long-period grating sensors: characteristics and application , 2003 .

[35]  P. Rastogi,et al.  Relative humidity sensor with optical fiber Bragg gratings. , 2002, Optics letters.

[36]  R. Branson The effects of inadequate humidity. , 1998, Respiratory care clinics of North America.

[37]  Kyriacos Kalli,et al.  Fiber Bragg Gratings: Fundamentals and Applications in Telecommunications and Sensing , 2000 .

[38]  S. Korposh,et al.  Simultaneous temperature and humidity measurements in a mechanical ventilator using an optical fibre sensor , 2016, European Workshop on Optical Fibre Sensors.

[39]  E Schena,et al.  Mechanical ventilation with heated humidifiers: measurements of condensed water mass within the breathing circuit according to ventilatory settings. , 2013, Physiological measurement.

[40]  Xinyong Dong,et al.  Polyvinyl alcohol-coated hybrid fiber grating for relative humidity sensing. , 2011, Journal of biomedical optics.

[41]  Yang Liu,et al.  A relative humidity sensor using a hydrogel-coated long period grating , 2007 .

[42]  Qida Zhao,et al.  Relative Humidity Sensor Based on Tilted Fiber Bragg Grating With Polyvinyl Alcohol Coating , 2009, IEEE Photonics Technology Letters.

[43]  Emiliano Schena,et al.  Performances of heated wire humidifiers during adult mechanical ventilation: Estimation of the amount of condensation , 2016, 2016 IEEE International Symposium on Medical Measurements and Applications (MeMeA).

[44]  R. Armisén Agar and agarose biotechnological applications , 1991, Hydrobiologia.

[45]  G. Park,et al.  Humidification of inspired gases during mechanical ventilation. , 2012, Minerva anestesiologica.

[46]  Byoungho Lee,et al.  Review of the present status of optical fiber sensors , 2003 .

[47]  Ping Lu,et al.  FIBER BRAGG GRATINGS AND THEIR APPLICATIONS AS TEMPERATURE AND HUMIDITY SENSORS , 2008 .

[48]  Yuliya Semenova,et al.  A miniature optical humidity sensor , 2011, 2011 IEEE SENSORS Proceedings.

[49]  T. L. Yeo,et al.  Characterisation of a polymer-coated fibre Bragg grating sensor for relative humidity sensing , 2005 .

[50]  François Lellouche,et al.  Influence of ambient and ventilator output temperatures on performance of heated-wire humidifiers. , 2004, American journal of respiratory and critical care medicine.