A real vessel phantom for imaging experimentation.

Vascular phantoms are used to evaluate imaging techniques such as ultrasound (US), CT, and angiography. They are expected to mimic the vasculature, surrounding tissue, and blood, and therefore must meet specific requirements on the mimicking materials, with respect to x-ray attenuation and acoustic properties (velocity, attenuation). In the past, researchers have used a variety of vessel models, including walled (typically latex tube) and wall-less phantoms (obtained by moulding a lumen in a block of agar). These models lacked the exact geometry of human vessels as well as pathologic features such as plaques and calcifications. To overcome these disadvantages, this paper describes a real vessel phantom for US and x-ray studies. The phantom consists of an agar-filled acrylic box containing a formaldehyde fixed section of a real human vessel (obtained at autopsy) cannulated onto two acrylic tubes. This phantom was evaluated by comparing the images obtained with x-ray angiography, CT, and 3-D B-mode US. The images show good overall correlation based on the location of the geometrical features within the phantom, such as lumen, plaques, and calcifications. Discrepancies, artifacts, and difficulties were minor, and are discussed. The use of a real vessel, with its natural geometry and pathology, makes this phantom attractive for evaluation of imaging techniques including projection radiography, CT and US, and for extending its use to MR and US based flow studies.

[1]  J W Hunt,et al.  The effect of refraction and assumed speeds of sound in tissue and blood on Doppler ultrasound blood velocity measurements. , 1995, Ultrasound in medicine & biology.

[2]  F Dunn,et al.  Ultrasonic propagation through fixed and unfixed tissues. , 1979, Ultrasound in medicine & biology.

[3]  M Kassam,et al.  Comparison of CW Doppler ultrasound spectra with the spectra derived from a flow visualization model. , 1986, Ultrasound in medicine & biology.

[4]  A Fenster,et al.  A high-resolution XRII-based quantitative volume CT scanner. , 1993, Medical physics.

[5]  D. A. Christopher,et al.  A wall-less vessel phantom for Doppler ultrasound studies. , 1995, Ultrasound in medicine & biology.

[6]  A. Fenster,et al.  A geometrically accurate vascular phantom for comparative studies of x-ray, ultrasound, and magnetic resonance vascular imaging: construction and geometrical verification. , 1993, Medical physics.

[7]  F. Foster,et al.  The Improvement and Quantitative Assessment of B-Mode Images Produced by an Annular Array/Cone Hybrid , 1983 .

[8]  R S Cobbold,et al.  On the design and evaluation of a steady flow model for Doppler ultrasound studies. , 1989, Ultrasound in medicine & biology.

[9]  W N McDicken,et al.  A versatile test-object for the calibration of ultrasonic Doppler flow instruments. , 1986, Ultrasound in medicine & biology.

[10]  Y Douville,et al.  An in vitro model and its application for the study of carotid Doppler spectral broadening. , 1983, Ultrasound in medicine & biology.

[11]  K Lackner,et al.  Quantification of vascular stenosis with color Doppler flow imaging: in vitro investigations. , 1991, Radiology.