Fast Monte Carlo fitting of two-layered tissue structures for short source-detector distances

New small-scale optical probes designed for endoscopic near-infrared imaging, can have source-detector distances considerably less than 1 cm, pushing the limits for which the diffusion approximation is valid for quantifying optical properties. Scalable Monte Carlo algorithms have been successful in recovering optical properties in this realm for homogeneous tissue; however, these techniques are unsuitable for heterogeneous media. The purpose of this study was to implement a fast Monte Carlo algorithm to retrieve optical properties in media comprised of two distinct layers (a geometry similar to that which would be seen in endoscopic prostate imaging where the rectal wall is superficial to the prostate). A two-layer phantom was constructed from two materials with known optical properties (one 5-mm thick slab was placed on a 3-cm thick slab). The phantom was raster-scanned using a reflectance-based system with a 3-mm source-detector separation. Data was analyzed using Monte Carlo eXtreme as a forward model in an iterative fitting procedure. On average, 125 iterations per pixel were required for convergence (3.8 minutes of computational time on a single nVidia GTX480 GPU card). The errors in recovered absorption coefficients were 0.58% and 0.39% in the top and bottom layers, respectively. This work demonstrates the promise of ultrafast Monte Carlo algorithms for applications within an iterative fitting routine for geometries where the diffusion approximation fails.

[1]  S Andersson-Engels,et al.  Real-time method for fitting time-resolved reflectance and transmittance measurements with a monte carlo model. , 1998, Applied optics.

[2]  M. Patterson,et al.  Improved solutions of the steady-state and the time-resolved diffusion equations for reflectance from a semi-infinite turbid medium. , 1997, Journal of the Optical Society of America. A, Optics, image science, and vision.

[3]  David A Boas,et al.  Monte Carlo simulation of photon migration in 3D turbid media accelerated by graphics processing units. , 2009, Optics express.

[4]  Frank K. Tittel,et al.  The influence of boundary conditions on the accuracy of diffusion theory in time-resolved reflectance spectroscopy of biological tissues , 1995, Physics in medicine and biology.

[5]  M. Patterson,et al.  Noninvasive determination of the optical properties of two-layered turbid media , 1998 .

[6]  M S Patterson,et al.  Determination of the optical properties of turbid media from a single Monte Carlo simulation , 1996, Physics in medicine and biology.

[7]  Ting-Yim Lee,et al.  Comparison of time-resolved and continuous-wave near-infrared techniques for measuring cerebral blood flow in piglets. , 2010, Journal of biomedical optics.

[8]  Mark Emberton,et al.  Photodynamic therapy for prostate cancer—a review of current status and future promise , 2009, Nature Clinical Practice Urology.

[9]  Stefan Andersson-Engels,et al.  White Monte Carlo for time-resolved photon migration. , 2008, Journal of biomedical optics.

[10]  Kenneth M. Tichauer,et al.  Time-resolved near-infrared technique for bedside monitoring of absolute cerebral blood flow , 2010, BiOS.