Estimation of end-expiratory lung volume variations by optoelectronic plethysmography

ObjectiveTo test the capability of optoelectronic plethysmography (OEP) to monitor positive end-expiratory pressure (PEEP)-induced changes of end-expiratory lung volume (EELV) changes in mechanically ventilated paralyzed patients. DesignLaboratory and clinical investigation. SettingIntensive care unit of the Ospedale Maggiore Policlinico di Milano. PatientsA total of eight patients with respiratory failure of various degrees, sedated and paralyzed. InterventionsPEEP variations (±5 cm H2O) relative to the baseline PEEP of 10 cm H2O. Measurements and Main Results In the model protocol, we tested the reproducibility of the OEP by repeating volume measurements of a plastic torso model over a 21-hr period, every 30 mins. The variations of OEP measurements of the torso model (9337 mL value) were encountered in a range of 16 mL (sd = 4 mL). In the patient protocol, we measured the end-expiratory volume of the chest wall (EEVCW) breath-by-breath by OEP before, during, and after the PEEP increase/decrease and we compared its variations with the corresponding variations of EELV measured by helium dilution technique. The regression line between EELV changes measured by helium and EEVCW changes measured by OEP resulted very close to the identity line (slope 1.06, intercept −0.02 L, r2 = 0.89) and their difference was not related to their absolute magnitude. After PEEP increase, the new steady state of EEVCW was reached approximately in 15 breaths; and, after PEEP decrease, in 3–4 breaths. The slow increase in EEVCW was mainly because of the abdominal compartment. ConclusionOEP measurements of EEVCW accurately reflect the changes of EELV. Furthermore, OEP allows a continuous compartmental analysis, even during unsteady conditions.

[1]  P. Pelosi,et al.  Effects of positive end-expiratory pressure on regional distribution of tidal volume and recruitment in adult respiratory distress syndrome. , 1995, American journal of respiratory and critical care medicine.

[2]  B. Krieger,et al.  Determination of auto-PEEP during spontaneous and controlled ventilation by monitoring changes in end-expiratory thoracic gas volume. , 1989, Chest.

[3]  A Pedotti,et al.  Rib cage mechanics during quiet breathing and exercise in humans. , 1997, Journal of applied physiology.

[4]  K. Falke,et al.  Ventilation with end-expiratory pressure in acute lung disease. , 1972, The Journal of clinical investigation.

[5]  M. Sydow,et al.  Evaluation of respiratory inductive plethysmography in controlled ventilation: measurement of tidal volume and PEEP-induced changes of end-expiratory lung volume. , 1998, Chest.

[6]  B Jonson,et al.  Measurement of Functional Residual Capacity by Sulfur Hexafluoride Washout , 1985, Anesthesiology.

[7]  A. K. Laws Effects of induction of anaesthesia and muscle paralysis on functional residual capacity of the lungs , 1968, Canadian Anaesthetists' Society journal.

[8]  J. Takala,et al.  Validation of a new respiratory inductive plethysmograph , 2001, Acta anaesthesiologica Scandinavica.

[9]  S. J. Cala,et al.  Chest wall and lung volume estimation by optical reflectance motion analysis. , 1996, Journal of applied physiology.

[10]  A. Beckett,et al.  AKUFO AND IBARAPA. , 1965, Lancet.

[11]  Peter M. Suter,et al.  Optimum End-Expiratory Airway Pressure in Patients with Acute Pulmonary Failure , 1975 .

[12]  W. S. Fowler,et al.  Effects of general anesthesia, muscle paralysis, and mechanical ventilation on pulmonary nitrogen clearance. , 1971, Anesthesiology.

[13]  D. Mascheroni,et al.  Perioperative changes in functional residual capacity in morbidly obese patients. , 1988, British journal of anaesthesia.

[14]  J. Katz,et al.  Time Course and Mechanisms of Lung‐volume Increase with PEEP in Acute Pulmonary Failure , 1981, Anesthesiology.

[15]  A Pedotti,et al.  Optoelectronic plethysmography in intensive care patients. , 2000, American journal of respiratory and critical care medicine.

[16]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[17]  J P Costantino,et al.  Inductance plethysmography measurement of CPAP-induced changes in end-expiratory lung volume. , 1990, Journal of applied physiology.

[18]  G Ferrigno,et al.  Human respiratory muscle actions and control during exercise. , 1997, Journal of applied physiology.