Influence of pulse sequence, polarity and amplitude on magnetic stimulation of human and porcine peripheral nerve

1 Mammalian phrenic nerve, in a trough filled with saline, was excited by magnetic coil (MC)‐induced stimuli at defined stimulation sites, including the negative‐going first spatial derivative of the induced electric field along a straight nerve, at a bend in the nerve, and at a cut nerve ending. At all such sites, the largest amplitude response for a given stimulator output setting was elicited by an induced damped polyphasic pulse consisting of an initial quarter‐cycle hyperpolarization followed by a half‐cycle depolarization compared with a predominantly ‘monophasic’ quarter‐cycle depolarization. 2 Simulation studies demonstrated that the increased efficacy of the induced quarter‐cycle hyperpolarizing‐half‐cycle depolarizing polyphasic pulse was mainly attributed to the greater duration of the outward membrane current phase, resulting in a greater outward charge transfer afforded by the half‐cycle (i.e. quarter‐cycles 2 and 3). The advantage of a fast rising initial quarter‐cycle depolarization was more than offset by the slower rising, but longer duration depolarizing half‐cycle. 3 Simulation further revealed that the quarter‐cycle hyperpolarization‐half‐cycle depolarization showed only a 2.6 % lowering of peak outward current and a 3.5 % lowering of outward charge transfer at threshold, compared with a half‐cycle depolarization alone. Presumably, this slight increase in efficacy reflects modest reversal of Na+ inactivation by the very brief initial hyperpolarization. 4 In vitro, at low bath temperature, the nerve response to an initial quarter‐cycle depolarization declined in amplitude as the second hyperpolarizing phase progressively increased in amplitude and duration. This ‘pull‐down’ phenomenon nearly disappeared as the bath temperature approached 37 °C. Possibly, at the reduced temperature, delay in generation of the action potential permitted the hyperpolarization phase to reduce excitation. 5 Pull‐down was not observed in the thenar muscle responses to median nerve stimulation in a normal human at normal temperature. However, pull‐down emerged when the median nerve was cooled by placing ice over the forearm. 6 In a nerve at subnormal temperature straddled with non‐conducting inhomogeneities, polyphasic pulses of either polarity elicited the largest responses. This was also seen when stimulating distal median nerve at normal temperature. These results imply excitation by hyperpolarizing‐depolarizing pulse sequences at two separate sites. Similarly, polyphasic pulses elicited the largest responses from nerve roots and motor cortex. 7 The pull‐down phenomenon has a possible clinical application in detecting pathologically slowed activation of Na+ channels. The current direction of the polyphasic waveform may become a significant factor with the increasing use of repetitive magnetic stimulators which, for technical reasons, induce a cosine‐shaped half‐cycle, preceded and followed by quarter‐cycles of opposite polarity.

[1]  V. Amassian,et al.  A new method using neuromagnetic stimulation to measure conduction time within the cauda equina. , 1996, Electroencephalography and clinical neurophysiology.

[2]  Relevance of stimulus duration for activation of motor and sensory fibers: implications for the study of H-reflexes and magnetic stimulation. , 1992 .

[3]  V. Amassian,et al.  Magnetic coil stimulation of straight and bent amphibian and mammalian peripheral nerve in vitro: locus of excitation. , 1993, The Journal of physiology.

[4]  M. Hallett,et al.  Determining the site of stimulation during magnetic stimulation of a peripheral nerve. , 1992, Electroencephalography and clinical neurophysiology.

[5]  Shoogo Ueno,et al.  Experimental And Modeling Studies On Properties Of Nerve Excitation Elicited By Magnetic Stimulation , 1991, Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society Volume 13: 1991.

[6]  D. Durand,et al.  Modeling the effects of electric fields on nerve fibers: Determination of excitation thresholds , 1992, IEEE Transactions on Biomedical Engineering.

[7]  S Ueno,et al.  Importance of soft tissue inhomogeneity in magnetic peripheral nerve stimulation. , 1997, Electroencephalography and clinical neurophysiology.

[8]  P. Basser,et al.  Focal magnetic stimulation of an axon , 1994, IEEE Transactions on Biomedical Engineering.

[9]  D. McRobbie,et al.  Thresholds for biological effects of time-varying magnetic fields. , 1984, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[10]  A T Barker,et al.  Magnetic stimulation of the human brain and peripheral nervous system: an introduction and the results of an initial clinical evaluation. , 1987, Neurosurgery.

[11]  A T Barker,et al.  Magnetic nerve stimulation: the effect of waveform on efficiency, determination of neural membrane time constants and the measurement of stimulator output. , 1991, Electroencephalography and clinical neurophysiology. Supplement.

[12]  P. Basser,et al.  A model of the stimulation of a nerve fiber by electromagnetic induction , 1990, IEEE Transactions on Biomedical Engineering.

[13]  J Cadwell,et al.  Optimizing magnetic stimulator design. , 1991, Electroencephalography and clinical neurophysiology. Supplement.

[14]  A. V. Hill,et al.  Electric Excitation of Nerve , 1940, The Indian Medical Gazette.

[15]  Tomio Andoh,et al.  Effects of Stimulus Waveform on Magnetic Nerve Stimulation. , 1996 .

[16]  A. Hodgkin,et al.  The dual effect of membrane potential on sodium conductance in the giant axon of Loligo , 1952, The Journal of physiology.

[17]  M. Hallett,et al.  Relevance of stimulus duration for activation of motor and sensory fibers: implications for the study of H-reflexes and magnetic stimulation. , 1988, Electroencephalography and clinical neurophysiology.

[18]  D. Durand,et al.  A generalized cable equation for magnetic stimulation of axons , 1996, IEEE Transactions on Biomedical Engineering.

[19]  Warren M. Grill,et al.  Stimulus waveforms for selective neural stimulation , 1995 .

[20]  J. Patrick Reilly,et al.  Sensory Effects of Transient Electrical Stimulation - Evaluation with a Neuroelectric Model , 1985, IEEE Transactions on Biomedical Engineering.

[21]  A P Rudell,et al.  Measurement of the electric field induced into inhomogeneous volume conductors by magnetic coils: application to human spinal neurogeometry. , 1991, Electroencephalography and clinical neurophysiology.

[22]  Mark Hallett,et al.  A theoretical calculation of the electric field induced by magnetic stimulation of a peripheral nerve , 1990, Muscle & nerve.

[23]  Dominique M. Durand,et al.  Induced electric fields by magnetic stimulation in non-homogeneous conducting media , 1989, Images of the Twenty-First Century. Proceedings of the Annual International Engineering in Medicine and Biology Society,.

[24]  P S Tofts,et al.  The distribution of induced currents in magnetic stimulation of the nervous system. , 1990, Physics in medicine and biology.

[25]  M. H. Perrott,et al.  An efficient approach to ARMA modeling of biological systems with multiple inputs and delays , 1996, IEEE Transactions on Biomedical Engineering.

[26]  V. Amassian,et al.  Modelling magnetic coil excitation of human cerebral cortex with a peripheral nerve immersed in a brain-shaped volume conductor: the significance of fiber bending in excitation. , 1992, Electroencephalography and clinical neurophysiology.

[27]  M Hines,et al.  A program for simulation of nerve equations with branching geometries. , 1989, International journal of bio-medical computing.

[28]  Garnham Cw,et al.  Magnetic nerve stimulation: the effect of waveform on efficiency, determination of neural membrane time constants and the measurement of stimulator output. , 1991 .

[29]  D. Durand,et al.  Effects of induced electric fields on finite neuronal structures: a simulation study , 1993, IEEE Transactions on Biomedical Engineering.

[30]  N M Murray,et al.  The influence of stimulus type on the magnetic excitation of nerve structures. , 1990, Electroencephalography and clinical neurophysiology.