Haemocompatibility of membrane and bubble oxygenators

During clinical hypothermic cardiopulmonary bypass (CPB), the haemocompatibility of six groups of membrane oxygenators (Cobe CML2, Shiley M2000, Maxima, Bard HF4000, Bard HF5000, Capiox E has been studied in 60 patients having open-heart surgery. A standardized anaesthetic and perfusion protocol was used, during which the abilityof the perfusionist to achieve target blood gas values (PaO2 20kPa and PaCO2 5.3kPa: alpha-stat) using inline electrodes was assessed. Haemocompatibility was evaluated by measurement of platelet numbers and function, betathromboglobulin (BTG), plasma haemoglobin, complement (C3a des Arg) and white blood cell (WBC) count pre- and post-CPB. Platelet and WBC numbers were also measured every five minutes throughout CPB. All oxygenators allowed the perfusionist to control blood gases adequately to prescribed levels. There were only minor differences in the degree and pattern of platelet depletion, reduction in platelet aggregation, elevation of BTG and C3a des Arg observed between oxygenator groups, which did not appear to be influenced by membrane type (flat plate versus hollow fibre). The membrane oxygenator haematological data was amalgamated with that obtained in previous clinical studies using membrane and bubble oxygenators (Cobe CML, Polystan Venotherm, Harvey H 1700, Bentley BIO-10, Bentley 1 0B, Bentley 1 OPlus, Gambro 10 and Shiley S100A HED) in which a similar evaluation protocol was employed. Comparison of the percentage change in platelet count when the pre- and post-CPB values were compared, demonstrated statistically significantly less platelet depletion (p <0.001 ) in the membrane oxygenator groups (-0.2 ± 8.3%) when compared to the bubble oxygenator groups (-21.7 ± 8.7%). A significantly lower percentage rise in BTG was also observed in the membrane oxygenator group when compared to the bubble oxygenator groups (p <0.001 ). All oxygenator groups showed elevation of both WBC count and plasma haemoglobin with a nonspecific fall in platelet aggregation over the period of bypass but no significant differences could be found between the two types of oxygenator. Membrane oxygenators, when compared to bubble oxygenators, exhibit lower GME production and improved haemocompatibility and allow superior blood gas control. Membrane oxygenators manifestly must be the oxygenator type of choice for clinical CPB.

[1]  D. Pearson Blood gas control during cardiopulmonary bypass , 1988 .

[2]  R. Clayton,et al.  A clinical evaluation of the Bentley 10B and Bentley 10Plus bubble oxygenators , 1988 .

[3]  S. Meri,et al.  Complement activation during cardiopulmonary bypass in children. , 1988, Complement.

[4]  S. Poslad,et al.  A clinical evaluation of the performance characteristics of one membrane and five bubble oxygenators: haemocompatibility studies , 1986 .

[5]  L. Henriksen Brain Luxury Perfusion during Cardiopulmonary Bypass in Humans. A Study of the Cerebral Blood Flow Response to Changes in CO2, O2, and Blood Pressure , 1986, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[6]  P. Myerowitz,et al.  Ectothermic philosophy of acid-base balance to prevent fibrillation during hypothermia. , 1986, Archives of surgery.

[7]  S. Poslad,et al.  A clinical evaluation of the performance characteristics of one membrane and five bubble oxygenators: gas transfer and gaseous microemboli production , 1986 .

[8]  A. Carpentier,et al.  Deleterious effects of cardiopulmonary bypass. A prospective study of bubble versus membrane oxygenation. , 1985, The Journal of thoracic and cardiovascular surgery.

[9]  L. Eysman,et al.  Reduced platelet activation and improved hemostasis after controlled cardiotomy suction during clinical membrane oxygenator perfusions. , 1985, The Journal of thoracic and cardiovascular surgery.

[10]  S. Poslad,et al.  A clinical evaluation of the gas transfer characteristics and gaseous microemboli production of two bubble oxygenators. , 1984, Life support systems : the journal of the European Society for Artificial Organs.

[11]  R. M. Peters,et al.  The effect of pH on the hypothermic ventricular fibrillation threshold. , 1984, The Journal of thoracic and cardiovascular surgery.

[12]  C. Wildevuur,et al.  Two membrane oxygenators and a bubbler: a clinical comparison. , 1983, The Annals of thoracic surgery.

[13]  R. Colman,et al.  Platelet function during cardiac operation: comparison of membrane and bubble oxygenators. , 1982, The Journal of thoracic and cardiovascular surgery.

[14]  C. Wildevuur,et al.  Clinical study of blood trauma during perfusion with membrane and bubble oxygenators. , 1982, The Journal of thoracic and cardiovascular surgery.

[15]  M. G. Lötter,et al.  Kinetics and sites of sequestration of indium 111-labeled human platelets during cardiopulmonary bypass. , 1981, The Journal of thoracic and cardiovascular surgery.

[16]  D. Stroncek,et al.  Complement activation and neutropenia occurring during cardiopulmonary bypass. , 1981, The Journal of thoracic and cardiovascular surgery.

[17]  E. Blackstone,et al.  Complement activation during cardiopulmonary bypass: evidence for generation of C3a and C5a anaphylatoxins. , 1981, The New England journal of medicine.

[18]  D. T. Pearson,et al.  Gaseous microemboli during open heart surgery , 1981 .

[19]  E. Hessel,et al.  Mechanism of abnormal bleeding in patients undergoing cardiopulmonary bypass: acquired transient platelet dysfunction associated with selective alpha-granule release. , 1980, Blood.

[20]  D. Nicoloff,et al.  A comparison of the effects of membrane and bubble oxygenators on platelet counts and platelet size in elective cardiac operations. , 1980, The Annals of thoracic surgery.

[21]  E. Peirce The membrane versus bubble oxygenator controversy. , 1980, The Annals of thoracic surgery.

[22]  R. Sade,et al.  A prospective randomized study of membrane versus bubble oxygenators in children. , 1980, The Annals of thoracic surgery.

[23]  R. Colman,et al.  Thromboxane synthesis and platelet secretion during cardiopulmonary bypass with bubble oxygenator. , 1980, The Journal of thoracic and cardiovascular surgery.

[24]  G. Davies-Jones,et al.  Thrombocytosis, circulating platelet aggregates, and neurological dysfunction. , 1979, British medical journal.

[25]  J. C. F. de Jong,et al.  Platelet Behavior in Extracorporeal Circulation (ECC) , 1979, Transfusion.

[26]  C. Beurling-Harbury,et al.  Acquired decrease in platelet secretory ADP associated with increased postoperative bleeding in post-cardiopulmonary bypass patients and in patients with severe valvular heart disease. , 1978, Blood.

[27]  D. Vanderjagt,et al.  Use of tetramethylbenzidine in plasma hemoglobin assay. , 1977, Clinical chemistry.

[28]  R. Bick,et al.  Alterations of hemostasis associated with cardiopulmonary bypass. , 1976, Thrombosis research.

[29]  N. Grover,et al.  The influence of cardiopulmonary bypass on the size of human platelets. , 1975, The Journal of thoracic and cardiovascular surgery.

[30]  J D Hellums,et al.  Morphological, biochemical, and functional changes in human platelets subjected to shear stress. , 1975, The Journal of laboratory and clinical medicine.

[31]  F. Bachmann,et al.  The hemostatic mechanism after open-heart surgery. II. Frequency of abnormal platelet functions during and after extracorporeal circulation. , 1975, The Journal of thoracic and cardiovascular surgery.

[32]  G. Noon,et al.  Cardiopulmonary Bypass: Microembolization and Platelet Aggregation , 1975, Circulation.

[33]  E. Salzman Blood Platelets and Extracorporeal Circulation * , 1963, Kyobu geka. The Japanese journal of thoracic surgery.

[34]  R. Dutton,et al.  Platelet aggregate emboli produced in patients during cardiopulmonary bypass with membrane and bubble oxygenators and blood filters. , 1974, The Journal of thoracic and cardiovascular surgery.

[35]  W. Zingg,et al.  Reduction in platelet adhesion to biomaterials by removal of gas nuclei. , 1974, Transactions - American Society for Artificial Internal Organs.

[36]  D. McGoon,et al.  Bleeding patterns after open-heart surgery. , 1970, The Journal of thoracic and cardiovascular surgery.

[37]  M. Andersen,et al.  Blood trauma produced by pump oxygenators: a comparative study of five different units. , 1969, Journal of Thoracic and Cardiovascular Surgery.

[38]  J. Goffinet,et al.  Profound neutropenia during the early phase of hemodialysis. , 1968, JAMA.

[39]  G. Born,et al.  Aggregation of Blood Platelets by Adenosine Diphosphate and its Reversal , 1962, Nature.

[40]  W. Krivit,et al.  Problems in hemostasis during openheart surgery. IV. On the changes in the blood clotting mechanism during cardiopulmonary bypass procedures. , 1962, Annals of surgery.