Power Transfer by Volume Conduction: In Vitro Validated Analytical Models Predict DC Powers Above 1 mW in Injectable Implants

Galvanic coupling, or more precisely volume conduction, has been recently studied by different research groups as a method for intrabody communications. However, only in a very few occasions its use for powering implants has been proposed and proper analyses of such capability are still lacking. We present the development and the in vitro validation of a set of analytical expressions able to estimate the maximum ac and dc powers attainable in elongated implants powered by volume conduction. In particular, the expressions do not describe the complete power transfer channel but the behavior of the implants when the presence of an electric field is assumed. The expressions and the in vitro models indicate that time-averaged powers above 1 mW can be readily obtained in very thin (diameter < 1 mm) and short (length < 15 mm) implants when ac fields that comply with safety standards are present in the tissues where the implants are located. The expressions and the in vitro models also indicate that the obtained dc power is maximized by delivering the ac field in the form of short bursts rather than continuously. The study results support the use of volume conduction as a safe option to power implants.

[1]  Takashi Ohira,et al.  Power efficiency and optimum load formulas on RF rectifiers featuring flow-angle equations , 2013, IEICE Electron. Express.

[2]  Ji-Woong Choi,et al.  Review of Near-Field Wireless Power and Communication for Biomedical Applications , 2017, IEEE Access.

[3]  Thomas Stieglitz,et al.  Original electronic design to perform epimysial and neural stimulation in paraplegia , 2008, Journal of neural engineering.

[4]  A. Sher,et al.  Photovoltaic Retinal Prosthesis with High Pixel Density , 2012, Nature Photonics.

[5]  Elad Alon,et al.  Model validation of untethered, ultrasonic neural dust motes for cortical recording , 2015, Journal of Neuroscience Methods.

[6]  Wouter A. Serdijn,et al.  A 60 mV Input Voltage, Process Tolerant Start-Up System for Thermoelectric Energy Harvesting , 2018, IEEE Transactions on Circuits and Systems I: Regular Papers.

[7]  Victor Pikov,et al.  Wireless microstimulators for neural prosthetics. , 2011, Critical reviews in biomedical engineering.

[8]  Guang-Zhong Yang,et al.  From Wearable Sensors to Smart Implants-–Toward Pervasive and Personalized Healthcare , 2015, IEEE Transactions on Biomedical Engineering.

[9]  A. V. Vorst,et al.  RF/Microwave Interaction with Biological Tissues , 2006 .

[10]  Samuel R Ward,et al.  Density and hydration of fresh and fixed human skeletal muscle. , 2005, Journal of biomechanics.

[11]  Antoni Ivorra,et al.  Injectable Stimulators Based on Rectification of High Frequency Current Bursts: Power Efficiency of 2 mm Thick Prototypes , 2017 .

[12]  Mahdi Rasouli,et al.  Energy sources and their development for application in medical devices , 2010, Expert review of medical devices.

[13]  Rong Luo,et al.  A Tissue-Channel Transcutaneous Power Transfer Technique for Implantable Devices , 2018, IEEE Transactions on Power Electronics.

[14]  Charles Polk,et al.  CRC Handbook of Biological Effects of Electromagnetic Fields , 1986 .

[15]  Menachem Nathan,et al.  Microbattery technologies for miniaturized implantable medical devices. , 2010, Current pharmaceutical biotechnology.

[16]  Konstantina S. Nikita,et al.  A Review of In-Body Biotelemetry Devices: Implantables, Ingestibles, and Injectables , 2017, IEEE Transactions on Biomedical Engineering.

[17]  Shanshan Zhan,et al.  Volume conduction energy transfer for implantable devices , 2013, Journal of biomedical research.

[18]  Andrew David Dehennis,et al.  A near-field-communication (NFC) enabled wireless fluorimeter for fully implantable biosensing applications , 2013, 2013 IEEE International Solid-State Circuits Conference Digest of Technical Papers.

[19]  Paul P Breen,et al.  BION microstimulators: a case study in the engineering of an electronic implantable medical device. , 2011, Medical engineering & physics.

[20]  A. Ivorra,et al.  Demonstration of 2 mm Thick Microcontrolled Injectable Stimulators Based on Rectification of High Frequency Current Bursts , 2017, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[21]  Yuji Tanabe,et al.  Wireless power transfer to deep-tissue microimplants , 2014, Proceedings of the National Academy of Sciences.

[22]  国際非電離放射線防護委員会 ICNIRP statement on the "Guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields (up to 300 GHz)". , 2009, Health physics.

[23]  Abbas Z. Kouzani,et al.  A Review on Miniaturized Ultrasonic Wireless Power Transfer to Implantable Medical Devices , 2019, IEEE Access.

[24]  Wei Zheng,et al.  The injectable neurostimulator: an emerging therapeutic device. , 2015, Trends in biotechnology.

[25]  Amin Arbabian,et al.  End-to-End Design of Efficient Ultrasonic Power Links for Scaling Towards Submillimeter Implantable Receivers , 2018, IEEE Transactions on Biomedical Circuits and Systems.

[26]  P R Troyk,et al.  Injectable electronic identification, monitoring, and stimulation systems. , 1999, Annual review of biomedical engineering.

[27]  Chulhun Seo,et al.  Modeling and Experimental Validation of a Butterfly-Shaped Wireless Power Transfer in Biomedical Implants , 2019, IEEE Access.

[28]  Sverre Grimnes,et al.  Passive Tissue Electrical Properties , 2008 .

[29]  Maysam Ghovanloo,et al.  Optimal Design of Wireless Power Transmission Links for Millimeter-Sized Biomedical Implants , 2016, IEEE Transactions on Biomedical Circuits and Systems.

[30]  Irbaz Bin Riaz,et al.  Leadless pacemakers: A new era in cardiac pacing. , 2016, Journal of cardiology.

[31]  Amir M. Sodagar,et al.  Modeling and Experimental Validation of a Capacitive Link for Wireless Power Transfer to Biomedical Implants , 2018, IEEE Transactions on Circuits and Systems II: Express Briefs.

[32]  Michael Faulkner,et al.  A Survey on Intrabody Communications for Body Area Network Applications , 2013, IEEE Transactions on Biomedical Engineering.

[33]  Victor Pikov,et al.  Bioelectronic medicines: a research roadmap , 2014, Nature Reviews Drug Discovery.

[34]  D. S. Freedman,et al.  Floating light-activated microelectrical stimulators tested in the rat spinal cord , 2011, Journal of neural engineering.

[35]  Maysam Ghovanloo,et al.  A wideband frequency-shift keying wireless link for inductively powered biomedical implants , 2004, IEEE Transactions on Circuits and Systems I: Regular Papers.

[36]  Mehdi Kiani,et al.  A Comprehensive Comparative Study on Inductive and Ultrasonic Wireless Power Transmission to Biomedical Implants. , 2018, IEEE sensors journal.

[37]  Maysam Ghovanloo,et al.  Robust Wireless Power Transmission to mm-Sized Free-Floating Distributed Implants , 2017, IEEE Transactions on Biomedical Circuits and Systems.

[38]  J. Patrick Reilly,et al.  Applied Bioelectricity: From Electrical Stimulation to Electropathology , 1998 .

[40]  K. Jokela,et al.  ICNIRP Guidelines GUIDELINES FOR LIMITING EXPOSURE TO TIME-VARYING , 1998 .

[41]  Babak Ziaie,et al.  New and Emerging Energy Sources for Implantable Wireless Microdevices , 2015, IEEE Access.

[42]  Steven Andrew Hackworth,et al.  Design, optimization, and implementation of a volume conduction energy transfer platform for implantable devices , 2010 .

[43]  Nitish V. Thakor,et al.  Wireless Power Delivery to Flexible Subcutaneous Implants Using Capacitive Coupling , 2017, IEEE Transactions on Microwave Theory and Techniques.

[44]  Gordon Bell,et al.  The body electric , 1997, CACM.

[45]  Mauro Serpelloni,et al.  Kinetic and thermal energy harvesters for implantable medical devices and biomedical autonomous sensors , 2013 .

[46]  Silvestro Micera,et al.  A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems , 2005, Journal of the peripheral nervous system : JPNS.

[47]  Antoni Ivorra,et al.  In vivo demonstration of injectable microstimulators based on charge-balanced rectification of epidermically applied currents , 2015, Journal of neural engineering.

[48]  Amir M. Sodagar,et al.  Capacitive coupling for power and data telemetry to implantable biomedical microsystems , 2009, 2009 4th International IEEE/EMBS Conference on Neural Engineering.