Prior stimulation and the masking-level difference.
暂无分享,去创建一个
Signal detection in diotic (NoSo) and dichotic (NoS pi) conditions was measured as a function of the stimulus parameters of the noise that preceded the signal-plus-masker. When the signal and masker were both pulsed, dichotic signal detection was worse than when the masker was continuous or when the onset of the masker preceded the signal-plus-masker by at least 500 ms. The dichotic detection thresholds decreased as the duration of the pulsed signal plus pulsed masker was increased. The level, spectrum, interaural configuration, duration, and temporal proximity of the prior noise (forward fringe) relative to the masker and/or signal and masker were all investigated. Almost any difference between the parameters of the fringe and the masker resulted in poorer signal detection in the dichotic conditions. These same stimulus conditions produced small (less than 2.2 dB) changes in the diotic detection thresholds. The various models of the Masking-Level Difference (MLD) may be modified to qualitatively describe some of these results.