3D radial sampling and 3D affine transform‐based respiratory motion correction technique for free‐breathing whole‐heart coronary MRA with 100% imaging efficiency

The navigator gating and slice tracking approach currently used for respiratory motion compensation during free‐breathing coronary magnetic resonance angiography (MRA) has low imaging efficiency (typically 30–50%), resulting in long imaging times. In this work, a novel respiratory motion correction technique with 100% scan efficiency was developed for free‐breathing whole‐heart coronary MRA. The navigator signal was used as a reference respiratory signal to segment the data into six bins. 3D projection reconstruction k‐space sampling was used for data acquisition and enabled reconstruction of low resolution images within each respiratory bin. The motion between bins was estimated by image registration with a 3D affine transform. The data from the different respiratory bins was retrospectively combined after motion correction to produce the final image. The proposed method was compared with a traditional navigator gating approach in nine healthy subjects. The proposed technique acquired whole‐heart coronary MRA with 1.0 mm3 isotropic spatial resolution in a scan time of 6.8 ± 0.9 min, compared with 16.2 ± 2.8 min for the navigator gating approach. The image quality scores, and length, diameter and sharpness of the right coronary artery (RCA), left anterior descending coronary artery (LAD), and left circumflex coronary artery (LCX) were similar for both approaches (P > 0.05 for all), but the proposed technique reduced scan time by a factor of 2.5. Magn Reson Med, 2011. © 2011 Wiley‐Liss, Inc.

[1]  Debiao Li,et al.  Contrast-enhanced whole-heart coronary magnetic resonance angiography at 3.0-T: a comparative study with X-ray angiography in a single center. , 2009, Journal of the American College of Cardiology.

[2]  P. Wielopolski,et al.  Coronary arteries: magnetization-prepared contrast-enhanced three-dimensional volume-targeted breath-hold MR angiography. , 2001, Radiology.

[3]  Kate McLeish,et al.  Free‐breathing radial acquisitions of the heart , 2004, Magnetic resonance in medicine.

[4]  V Rasche,et al.  Motion compensated projection reconstruction , 1999, Magnetic resonance in medicine.

[5]  Kan Takeda,et al.  Detection of coronary artery stenosis with whole-heart coronary magnetic resonance angiography. , 2006, Journal of the American College of Cardiology.

[6]  Debiao Li,et al.  A respiratory self‐gating technique with 3D‐translation compensation for free‐breathing whole‐heart coronary MRA , 2009, Magnetic resonance in medicine.

[7]  O Dössel,et al.  Fast isotropic volumetric coronary MR angiography using free‐breathing 3D radial balanced FFE acquisition , 2004, Magnetic resonance in medicine.

[8]  D. Pennell,et al.  Calculation of a subject-specific adaptive motion-correction factor for improved real-time navigator echo-gated magnetic resonance coronary angiography. , 1999, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[9]  Alastair J. Martin,et al.  Whole‐heart steady‐state free precession coronary artery magnetic resonance angiography , 2003, Magnetic resonance in medicine.

[10]  P. Börnert,et al.  Free‐breathing whole‐heart coronary MRA with 3D radial SSFP and self‐navigated image reconstruction , 2005, Magnetic resonance in medicine.

[11]  Pascal Spincemaille,et al.  Cardiac fat navigator‐gated steady‐state free precession 3D magnetic resonance angiography of coronary arteries , 2006, Magnetic resonance in medicine.

[12]  Guang-Zhong Yang,et al.  Non‐model‐based correction of respiratory motion using beat‐to‐beat 3D spiral fat‐selective imaging , 2007, Journal of magnetic resonance imaging : JMRI.

[13]  G H Glover,et al.  Projection Reconstruction Techniques for Reduction of Motion Effects in MRI , 1992, Magnetic resonance in medicine.

[14]  Yi Wang,et al.  Direct monitoring of coronary artery motion with cardiac fat navigator echoes , 2003, Magnetic resonance in medicine.

[15]  J Hennig,et al.  Eddy current optimized phase encoding schemes to reduce artifacts in balanced SSFP imaging , 2003 .

[16]  M. McConnell,et al.  Prospective navigator correction of image position for coronary MR angiography. , 1997, Radiology.

[17]  René M. Botnar,et al.  Free-breathing 3D steady-state free precession coronary MR angiography with radial k-space sampling: comparison with cartesian k-space sampling and cartesian gradient-echo coronary MR angiography--pilot study. , 2004, Radiology.

[18]  Sam T. S. Wong,et al.  A strategy for sampling on a sphere applied to 3D selective RF pulse design , 1994, Magnetic resonance in medicine.

[19]  Peter Kellman,et al.  Fully automatic, retrospective enhancement of real‐time acquired cardiac cine MR images using image‐based navigators and respiratory motion‐corrected averaging , 2008, Magnetic resonance in medicine.

[20]  P. Börnert,et al.  Novel prospective respiratory motion correction approach for free‐breathing coronary MR angiography using a patient‐adapted affine motion model , 2003, Magnetic resonance in medicine.

[21]  J. Pipe,et al.  Sampling density compensation in MRI: Rationale and an iterative numerical solution , 1999, Magnetic resonance in medicine.

[22]  D. Firmin,et al.  Phase ordering with automatic window selection (PAWS): A novel motion‐resistant technique for 3D coronary imaging , 2000, Magnetic resonance in medicine.

[23]  Todd S. Sachs,et al.  The diminishing variance algorithm for real‐time reduction of motion artifacts in MRI , 1995, Magnetic resonance in medicine.

[24]  Olaf Dössel,et al.  Model evaluation and calibration for prospective respiratory motion correction in coronary MR angiography based on 3-D image registration , 2002, IEEE Transactions on Medical Imaging.

[25]  A. Macovski,et al.  Selection of a convolution function for Fourier inversion using gridding [computerised tomography application]. , 1991, IEEE transactions on medical imaging.

[26]  S. Riederer,et al.  Respiratory Motion of the Heart: Kinematics and the Implications for the Spatial Resolution in Coronary Imaging , 1995, Magnetic resonance in medicine.

[27]  Debiao Li,et al.  Reduction of transient signal oscillations in true‐FISP using a linear flip angle series magnetization preparation , 2003, Magnetic resonance in medicine.