The Building Fabric Thermal Performance of Passivhaus Dwellings—Does It Do What It Says on the Tin?

The Passivhaus (or Passive House) Standard is one of the world’s most widely known voluntary energy performance standards. For a dwelling to achieve the Standard and be granted Certification, the building fabric requires careful design and detailing, high levels of thermal insulation, building airtightness, close site supervision and careful workmanship. However, achieving Passivhaus Certification is not a guarantee that the thermal performance of the building fabric as designed will actually be achieved in situ. This paper presents the results obtained from measuring the in situ whole building heat loss coefficient (HLC) of a small number of Certified Passivhaus case study dwellings. They are located on different sites and constructed using different technologies in the UK. Despite the small and non-random nature of the dwelling sample, the results obtained from the in situ measurements revealed that the thermal performance of the building fabric, for all of the dwellings, performed very close to the design predictions. This suggests that in terms of the thermal performance of the building fabric, Passivhaus does exactly what it says on the tin.

[1]  David T. Harrje,et al.  Documenting air movements and infiltration in multicell buildings using various tracer-gas techniques , 1985 .

[2]  Hugo Hens,et al.  Comparison of measurements and simulations of a passive house , 2005 .

[3]  Sivert Uvsløkk,et al.  The Importance of Wind Barriers for Insulated Timber Frame Constructions , 1996 .

[4]  Sf Stamp Assessing uncertainty in co-heating tests: Calibrating a whole building steady state heat loss measurement method , 2016 .

[5]  J. D. Balcomb,et al.  Short-Term Energy Monitoring (STEM): Application of the PSTAR method to a residence in Fredericksburg, Virginia , 1988 .

[6]  K. Shadan,et al.  Available online: , 2012 .

[7]  武彦 福島 持続可能性(Sustainability)の要件 , 2006 .

[8]  Andreas H. Hermelink,et al.  CEPHEUS results : measurements and occupants' satisfaction provide evidence for Passive Houses being an option for sustainable building , 2006 .

[9]  Eric Mangematin,et al.  Quick measurements of energy efficiency of buildings , 2012 .

[10]  V. Rich Personal communication , 1989, Nature.

[11]  Bob Davis,et al.  Measuring residential duct efficiency with the short-term coheat test methodology , 2006 .

[12]  Robert Lowe,et al.  Evaluating the impact of an enhanced energy performance standard on load-bearing masonry domestic construction: Understanding the gap between designed and real performance: lessons from Stamford Brook. , 2011 .

[13]  P. E. Condon,et al.  In-situ measurements of residential energy performance using electric co-heating , 1980 .

[14]  David Johnston,et al.  Whole House Heat Loss Test Method (Coheating) , 2012 .

[15]  Viktor Dorer,et al.  Re-inventing air heating: Convenient and comfortable within the frame of the Passive House concept , 2005 .

[16]  Olivia Guerra-Santin,et al.  Monitoring the performance of low energy dwellings: Two UK case studies , 2013 .