A field measurement study of a parallel-flow push–pull system for industrial ventilation applications

ABSTRACT The initial characteristics of a jet have a strong effect on velocity distribution during its development, and the resulting contaminant distribution and ventilation system performance will also change correspondingly. To achieve quantitative improvement by adopting a parallel-flow jet than a normal jet accurately, the velocity and contaminant distribution associated with a parallel-flow push--pull ventilation system (the parallel-flow opening: the first non-uniform perforated plate: porosity Φ = 17.48%; the second uniform perforated plate: porosity Φ = 16.63%; the honeycomb: length l = 2 mm, depth d = 42 mm) and a normal push--pull ventilation system (the shutter opening: the effective area coefficient ϵ = 85%) under the same conditions were experimentally studied, respectively. An accurate calculation method for the size of the main polluted region is proposed to reflect the contaminant diffusion region. The results showed that by adopting the parallel-flow jet, the standard deviation of the velocity on the push open face was reduced by 61%. The main polluted zone was reduced by 75%. When the capture effect was satisfied, the capture efficiency was improved by 0.63% and indoor air quality was improved by 5%. The conclusions of this investigation can serve as a reference for quantitatively improving the push--pull ventilation system performance.

[1]  Derek B. Ingham,et al.  Numerical modelling of the flow patterns induced by a push-pull ventilation system , 1996 .

[2]  J. Sundell,et al.  What we know, and don`t know about sick building syndrome , 1996 .

[3]  Konstantinos-Stefanos Nikas,et al.  Experimental and numerical investigation of the tracer gas methodology in the case of a naturally cross-ventilated building , 2012 .

[4]  Dominique Marchio,et al.  CO2 tracer gas concentration decay method for measuring air change rate , 2015 .

[5]  Jeffrey S. Marshall,et al.  A CO2 tracer-gas method for local air leakage detection and characterization , 2014 .

[6]  中华人民共和国国家统计局人口和就业统计司 中国人口和就业统计年鉴 = China population and employment statistics yearbook , 2007 .

[7]  R Rota,et al.  Design guidelines for push-pull ventilation systems through computational fluid dynamics modeling. , 2001, AIHAJ : a journal for the science of occupational and environmental health and safety.

[8]  Chao-Hsin Lin,et al.  Experimental study of gaseous and particulate contaminants distribution in an aircraft cabin , 2013, Atmospheric Environment.

[9]  Ming-Jyh Chern,et al.  Numerical Investigation and Recommendations for Push-Pull Ventilation Systems , 2007, Journal of occupational and environmental hygiene.

[10]  Mike Robinson,et al.  RECOMMENDATIONS FOR THE DESIGN OF PUSH-PULL VENTILATION SYSTEMS FOR OPEN SURFACE TANKS , 1996 .

[11]  F Marzal,et al.  Visualization of airflows in push-pull ventilation systems applied to surface treatment tanks. , 2003, AIHA journal : a journal for the science of occupational and environmental health and safety.

[12]  K M MORSE Industrial ventilation. , 1946, What's new in industrial hygiene.

[13]  E. K. Chumachenko,et al.  Measuring and computational system of TsAGI T-128 transonic wind tunnel , 2011 .

[14]  Vinayak Kulkarni,et al.  Simulation of honeycomb–screen combinations for turbulence management in a subsonic wind tunnel , 2011 .

[15]  W A Burgess,et al.  Capture efficiency of local exhaust ventilation systems. , 1983, American Industrial Hygiene Association journal.

[16]  Jürgen Quest,et al.  A short history of the European Transonic Wind Tunnel ETW , 2011 .

[17]  Zhao Zhang,et al.  Experimental and numerical investigation of airflow and contaminant transport in an airliner cabin mockup , 2009 .

[18]  Yang Yang,et al.  An evaluation index for the control effect of the local ventilation systems on indoor air quality in industrial buildings , 2016 .

[19]  P Wargocki,et al.  Perceived air quality, sick building syndrome (SBS) symptoms and productivity in an office with two different pollution loads. , 1999, Indoor air.

[20]  Yuanhui Zhang,et al.  Experimental study of ventilation effectiveness and air velocity distribution in an aircraft cabin mockup , 2008 .

[21]  Adolfo Palombo,et al.  Push-pull ventilation system: a CFD approach for the performance analysis , 2007 .

[22]  J. Woods Cost avoidance and productivity in owning and operating buildings. , 1989, Occupational medicine.

[23]  Manuel Gameiro da Silva,et al.  Accuracy Limitations for Low-Velocity Measurements and Draft Assessment in Rooms , 2007 .