Sleep Apnea Detection with Polysomnography and Depth Sensors

This paper is devoted to proving two goals, to show that various depth sensors can be used to record breathing rate with the same accuracy as contact sensors used in polysomnography (PSG), in addition to proving that breathing signals from depth sensors have the same sensitivity to breathing changes as in PSG records. The breathing signal from depth sensors can be used for classification of sleep apnea events with the same success rate as with PSG data. The recent development of computational technologies has led to a big leap in the usability of range imaging sensors. New depth sensors are smaller, have a higher sampling rate, with better resolution, and have bigger precision. They are widely used for computer vision in robotics, but they can be used as non-contact and non-invasive systems for monitoring breathing and its features. The breathing rate can be easily represented as the frequency of a recorded signal. All tested depth sensors (MS Kinect v2, RealSense SR300, R200, D415 and D435) are capable of recording depth data with enough precision in depth sensing and sampling frequency in time (20–35 frames per second (FPS)) to capture breathing rate. The spectral analysis shows a breathing rate between 0.2 Hz and 0.33 Hz, which corresponds to the breathing rate of an adult person during sleep. To test the quality of breathing signal processed by the proposed workflow, a neural network classifier (simple competitive NN) was trained on a set of 57 whole night polysomnographic records with a classification of sleep apneas by a sleep specialist. The resulting classifier can mark all apnea events with 100% accuracy when compared to the classification of a sleep specialist, which is useful to estimate the number of events per hour. When compared to the classification of polysomnographic breathing signal segments by a sleep specialist, which is used for calculating length of the event, the classifier has an F1 score of 92.2% Accuracy of 96.8% (sensitivity 89.1% and specificity 98.8%). The classifier also proves successful when tested on breathing signals from MS Kinect v2 and RealSense R200 with simulated sleep apnea events. The whole process can be fully automatic after implementation of automatic chest area segmentation of depth data.

[1]  A. Rodríguez-Molinero,et al.  Normal Respiratory Rate and Peripheral Blood Oxygen Saturation in the Elderly Population , 2013, Journal of the American Geriatrics Society.

[2]  Rainer Stiefelhagen,et al.  Breathing Rate Monitoring during Sleep from a Depth Camera under Real-Life Conditions , 2017, 2017 IEEE Winter Conference on Applications of Computer Vision (WACV).

[3]  Pubudu N. Pathirana,et al.  Respiration rate and breathing patterns from Doppler radar measurements , 2014, 2014 IEEE Conference on Biomedical Engineering and Sciences (IECBES).

[4]  Changzhan Gu,et al.  Assessment of Human Respiration Patterns via Noncontact Sensing Using Doppler Multi-Radar System , 2015, Sensors.

[5]  Jean-Marc Ginoux,et al.  An Ultrasonic Contactless Sensor for Breathing Monitoring , 2014, Sensors.

[6]  C. Sullivan,et al.  Reversal of central sleep apnea using nasal CPAP. , 1986, Chest.

[7]  Ennio Gambi,et al.  A Human Activity Recognition System Using Skeleton Data from RGBD Sensors , 2016, Comput. Intell. Neurosci..

[8]  Joan Lasenby,et al.  TIDAL BREATHING PARAMETERS MEASURED BY STRUCTURED LIGHT PLETHYSMOGRAPHY (SLP) AND SPIROMETRY , 2010, ATS 2010.

[9]  N. Cherniack,et al.  Respiratory dysrhythmias during sleep. , 1981, The New England journal of medicine.

[10]  Gustavo Deco,et al.  Computational neuroscience of vision , 2002 .

[11]  Ales Procházka,et al.  Breathing Analysis Using Thermal and Depth Imaging Camera Video Records , 2017, Sensors.

[12]  Fatih Erden,et al.  Sensors in Assisted Living: A survey of signal and image processing methods , 2016, IEEE Signal Processing Magazine.

[13]  Martin Schätz,et al.  Motion tracking and gait feature estimation for recognising Parkinson’s disease using MS Kinect , 2015, BioMedical Engineering OnLine.

[14]  Ales Procházka,et al.  Statistical recognition of breathing by MS Kinect depth sensor , 2015, 2015 International Workshop on Computational Intelligence for Multimedia Understanding (IWCIM).

[15]  Hiroshi Nakajima,et al.  Monitoring of Weekly Sleep Pattern Variations at Home with a Contactless Biomotion Sensor , 2015, Sensors.

[16]  W C Dement,et al.  Insomnia with Sleep Apnea: A New Syndrome , 1973, Science.

[17]  K. Barrett,et al.  Ganong's Review of Medical Physiology , 2010 .

[18]  Jian-Ru Chen,et al.  Unobtrusive Sleep Monitoring Using Movement Activity by Video Analysis , 2019, Electronics.

[19]  I. Pavlidis,et al.  Noncontact measurement of breathing function , 2006, IEEE Engineering in Medicine and Biology Magazine.

[20]  Yu Zhou,et al.  Leveraging Two Kinect Sensors for Accurate Full-Body Motion Capture , 2015, Sensors.

[21]  Andrew Hunter,et al.  Unconstrained Video Monitoring of Breathing Behavior and Application to Diagnosis of Sleep Apnea , 2014, IEEE Transactions on Biomedical Engineering.

[22]  Ales Procházka,et al.  Bayesian classification and analysis of gait disorders using image and depth sensors of Microsoft Kinect , 2015, Digit. Signal Process..

[23]  Anders Grunnet-Jepsen,et al.  Intel RealSense Stereoscopic Depth Cameras , 2017, CVPR 2017.

[24]  M Partinen,et al.  Central sleep apnea and partial obstruction of the upper airway , 1987, Annals of neurology.

[25]  Ales Procházka,et al.  Use of the image and depth sensors of the Microsoft Kinect for the detection of gait disorders , 2015, Neural Computing and Applications.

[26]  Wilburta Q. Lindh Delmar's Comprehensive Medical Assisting: Administrative and Clinical Competencies , 1997 .

[27]  Joan Lasenby,et al.  P134 Validating structured light plethysmography (SLP) as a non-invasive method of measuring lung function when compared to Spirometry , 2011, Thorax.

[28]  Didier Stricker,et al.  Comparison of Kinect V1 and V2 Depth Images in Terms of Accuracy and Precision , 2016, ACCV Workshops.

[29]  W. McNicholas,et al.  Clinical and physiologic heterogeneity of the central sleep apnea syndrome. , 2015, The American review of respiratory disease.

[30]  Philip Smit,et al.  Continuous respiratory rate monitoring during an acute hypoxic challenge using a depth sensing camera , 2019, Journal of Clinical Monitoring and Computing.

[31]  S. Winograd On computing the Discrete Fourier Transform. , 1976, Proceedings of the National Academy of Sciences of the United States of America.

[32]  Vladimir Stankovic,et al.  Sleep Apnea Detection via Depth Video and Audio Feature Learning , 2017, IEEE Transactions on Multimedia.

[33]  Yunyoung Nam,et al.  Sleep Monitoring Based on a Tri-Axial Accelerometer and a Pressure Sensor , 2016, Sensors.

[34]  Elise Lachat,et al.  Assessment and Calibration of a RGB-D Camera (Kinect v2 Sensor) Towards a Potential Use for Close-Range 3D Modeling , 2015, Remote. Sens..

[35]  A. Procházka,et al.  PILOT STUDY OF SLEEP APNEA DETECTION WITH WAVELET TRANSFORM , 2017 .

[36]  Cheng Yang,et al.  A Depth Camera Motion Analysis Framework for Tele-rehabilitation: Motion Capture and Person-Centric Kinematics Analysis , 2016, IEEE Journal of Selected Topics in Signal Processing.

[37]  E. MuthuSundhara Pandiyan,et al.  Force Sensitive Resistance Based Heart Beat Monitoring For Health Care System , 2014 .