Design considerations relating to non-thermal aspects of passive 2-phase immersion cooling

There is renewed interest in passive 2-phase immersion for cooling power electronics and high performance computers. This can be attributed to recent research showing its performance potential compared with more complex and costly techniques, to innovations that simplify its application and to a general trend toward higher power densities. Though the thermal performance capabilities of passive 2-phase immersion cooling are well documented, the technique is not widely practiced and system designers will find little published information concerning subtler and very critical aspects of system design. There is no manual, for example, concerning practical details like material compatibility, electrical signal integrity (SI), fluid decomposition, management of moisture and light gases, and so on. This paper presents a useful material compatibility test method and explains the mechanisms of distillation and extraction that are intrinsic to a refluxing 2-phase system and by which wetted materials interact with the fluid and each other. It discusses sources, implications and techniques for removal of organic contaminants, water, non-condensable air and fluid thermal decomposition products. Data are presented from sub-20GHz SI experiments conducted with backplane connectors and microstrip transmission lines submerged in two classes of environmentally sustainable working fluids. It is hoped that this overview will demystify these subjects for designers unfamiliar with passive 2-phase immersion cooling and encourage more widespread adoption of this elegant and proven technology.

[1]  Jorge Pontt,et al.  Recent advances in mining haul trucks , 2004, IEEE Transactions on Industrial Electronics.

[2]  Cindy M Barnes,et al.  Practical Considerations Relating to Immersion Cooling of Power Electronics in Traction Systems , 2010, IEEE Transactions on Power Electronics.

[3]  Walter Koellner,et al.  Increased productivity with AC drives for mining excavators and haul trucks , 2000, Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129).

[4]  M. Olszewski POTENTIAL REFRIGERANTS FOR POWER ELECTRONICS COOLING , 2006 .

[5]  P. Tuma,et al.  Fluoroketone C2F5C(O)CF(CF3)2 as a Heat Transfer Fluid for Passive and Pumped 2-Phase Applications , 2008, 2008 Twenty-fourth Annual IEEE Semiconductor Thermal Measurement and Management Symposium.

[6]  A. Drews Standard Test Method for Kauri-Butanol Value of Hydrocarbon Solvents , 1998 .

[7]  Phillip E Tuma,et al.  The merits of open bath immersion cooling of datacom equipment , 2010, 2010 26th Annual IEEE Semiconductor Thermal Measurement and Management Symposium (SEMI-THERM).

[8]  Barbara Minor,et al.  HFO-1234yf Low GWP Refrigerant Update , 2008 .

[9]  L.M. Tolbert,et al.  Two-Phase Cooling Method Using the R134a Refrigerant to Cool Power Electronic Devices , 2005, IEEE Transactions on Industry Applications.

[10]  C. Tantolin,et al.  Experimental study of immersion cooling for power components , 1994 .

[11]  L.M. Tolbert,et al.  Two-phase cooling method using R134a refrigerant to cool power electronic devices , 2007, Twentieth Annual IEEE Applied Power Electronics Conference and Exposition, 2005. APEC 2005..