A method to approximate a closest loadability limit using multiple load flow solutions

A new method is proposed to approximate a closest loadability limit (CLL), or closest saddle node bifurcation point for power systems, using a pair of multiple load flow solutions. More strictly, the obtainable points by the method are the stationary points including not only CLL but also farthest and saddle points. An operating solution and a low voltage load flow solution are used to efficiently estimate the node injections at a CLL as well as the left and right eigenvectors corresponding to the zero eigenvalue of the load flow Jacobian. They can be used in monitoring loadability margin, in identification of weak spots in a power system and in the examination of an optimal control against voltage collapse. Most of the computation time of the proposed method is taken in calculating the load flow solution pair. The remaining computation time is less than that of an ordinary load flow.

[1]  Y. Tayama,et al.  Voltage instability proximity index (VIPI) based on multiple load flow solutions in ill-conditioned power systems , 1988, Proceedings of the 27th IEEE Conference on Decision and Control.

[2]  Y. Tamura,et al.  Relationship Between Voltage Instability and Multiple Load FLow Solutions in Electric Power Systems , 1983, IEEE Transactions on Power Apparatus and Systems.

[3]  T.V. Cutsem,et al.  A method to compute reactive power margins with respect to v , 1991, IEEE Power Engineering Review.

[4]  M. Suzuki,et al.  Newly developed voltage security monitoring system , 1992 .

[5]  I. Dobson Observations on the geometry of saddle node bifurcation and voltage collapse in electrical power systems , 1992 .

[6]  Claudio A. Canizares,et al.  Point of collapse and continuation methods for large AC/DC systems , 1993 .

[7]  Thomas J. Overbye Use of energy methods for on-line assessment of power system voltage security , 1993 .

[8]  Thomas J. Overbye,et al.  Improved techniques for power system voltage stability assessment using energy methods , 1991 .

[9]  H. Chiang,et al.  A more efficient formulation for computation of the maximum loading points in electric power systems , 1995 .

[10]  F. Alvarado,et al.  Point of collapse methods applied to AC/DC power systems , 1992 .

[11]  Naoto Yorino,et al.  A simplified approach to estimate maximum loading conditions in the load flow problem , 1993 .

[12]  Naoto Yorino,et al.  On the Continuous Monitoring of Voltage Stability Margin in Electric Power Systems , 1988 .

[13]  F. Galiana,et al.  Quantitative Analysis of Steady State Stability in Power Networks , 1981, IEEE Transactions on Power Apparatus and Systems.

[14]  F. Alvarado,et al.  Computation of closest bifurcations in power systems , 1994 .

[15]  M. Kitagawa,et al.  An investigation of voltage instability problems , 1992 .

[16]  K. Iba,et al.  Calculation of critical loading condition with nose curve using homotopy continuation method , 1991 .

[17]  K. Iba,et al.  A method for finding a pair of multiple load flow solutions in bulk power systems , 1989, Conference Papers Power Industry Computer Application Conference.

[18]  Venkataramana Ajjarapu,et al.  The continuation power flow: a tool for steady state voltage stability analysis , 1991 .

[19]  I. Dobson,et al.  New methods for computing a closest saddle node bifurcation and worst case load power margin for voltage collapse , 1993 .

[20]  M. Kitagawa,et al.  An Effective Monitoring of Power System Voltage Stability by Means of Voltage Stability Indices , 1991 .