Deformable mock stenotic artery with a lipid pool.
暂无分享,去创建一个
J. Tardif | V. Pazos | R. Mongrain | J C Tardif | V Pazos | R Mongrain
[1] Masanori Kobayashi,et al. A two year in vivo study of polyvinyl alcohol-hydrogel (PVA-H) artificial meniscus. , 2005, Biomaterials.
[2] Azriel Rosenfeld,et al. Picture Processing and Psychopictorics , 1970 .
[3] R E Guldberg,et al. Mechanical properties of a novel PVA hydrogel in shear and unconfined compression. , 2001, Biomaterials.
[4] C. Tracy,et al. American College of Cardiology Clinical Expert Consensus Document on Standards for Acquisition, Measurement and Reporting of Intravascular Ultrasound Studies (IVUS). A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents. , 2001, Journal of the American College of Cardiology.
[5] Aaron Fenster,et al. A Pulsating Coronary Vessel Phantom for Two- and Three-Dimensional Intravascular Ultrasound Studies , 2001, MICCAI.
[6] D. Xiong,et al. A study on the friction properties of poly(vinyl alcohol) hydrogel as articular cartilage against titanium alloy , 2007 .
[7] Udo Hoffmann,et al. Arterial wall imaging: evaluation with 16-section multidetector CT in blood vessel phantoms and ex vivo coronary arteries. , 2006, Radiology.
[8] Matthew J. Allen,et al. Preclinical Evaluation of a Poly (Vinyl Alcohol) Hydrogel Implant as a Replacement for the Nucleus Pulposus , 2004, Spine.
[9] Wojciech Swieszkowski,et al. An elastic material for cartilage replacement in an arthritic shoulder joint. , 2006, Biomaterials.
[10] Hongjun Jiang,et al. Design and manufacture of a polyvinyl alcohol (PVA) cryogel tri-leaflet heart valve prosthesis. , 2004, Medical engineering & physics.
[11] B. Rutt,et al. Polyvinyl alcohol cryogel: An ideal phantom material for MR studies of arterial flow and elasticity , 1997, Magnetic resonance in medicine.
[12] Abhijeet Joshi,et al. Functional compressive mechanics of a PVA/PVP nucleus pulposus replacement. , 2006, Biomaterials.
[13] R. Niessner,et al. Acoustical properties of selected tissue phantom materials for ultrasound imaging , 2007, Physics in medicine and biology.
[14] C T Lancée,et al. Intravascular elasticity imaging using ultrasound: feasibility studies in phantoms. , 1997, Ultrasound in medicine & biology.
[15] H. ElMaraghy,et al. Curve and Surface Modeling with Uncertainties Using Dual Kriging , 1999 .
[16] J. Tardif,et al. Polyvinyl alcohol cryogel: optimizing the parameters of cryogenic treatment using hyperelastic models. , 2009, Journal of the mechanical behavior of biomedical materials.
[17] T. Peters,et al. Poly(vinyl alcohol) cryogel phantoms for use in ultrasound and MR imaging , 2004, Physics in medicine and biology.
[18] Frits Mastik,et al. A finite element model for performing intravascular ultrasound elastography of human atherosclerotic coronary arteries. , 2004, Ultrasound in medicine & biology.
[19] 高野 雅充. Mechanical and structural characteristics of vulnerable plaques : analysis by coronary angioscopy and intravascular ultrasound , 2002 .