Motion compensated projection reconstruction

Over recent years, MRI has shown the capability for real‐time applications. Although the acquisition times of fast MRI methods have been reduced significantly, patient motion during a magnetic resonance imaging (MRI) examination still causes artifacts in the image. In this paper, the effects of motion in MRI using a radial acquisition scheme are examined. It is shown that motion can be estimated without the use of additional measurement, based on the acquired projections only. A new reconstruction technique is introduced that integrates a motion compensation algorithm into the MR‐reconstruction process, resulting in a significant reduction of blurring artifacts in the reconstructed images. The proposed method is applied to different kinds of motion such as kinetic joint studies. Magn Reson Med 41:954–963, 1999. © 1999 Wiley‐Liss, Inc.

[1]  J. Felmlee,et al.  Orbital navigator echoes for motion measurements in magnetic resonance imaging , 1995, Magnetic resonance in medicine.

[2]  E Atalar,et al.  A respiratory motion artifact reduction method in magnetic resonance imaging of the chest. , 1991, IEEE transactions on medical imaging.

[3]  J. Pauly,et al.  Isotropic diffusion‐weighted and spiral‐navigated interleaved EPI for routine imaging of acute stroke , 1997, Magnetic resonance in medicine.

[4]  J N Lee,et al.  MR fluoroscopy: Technical feasibility , 1988, Magnetic resonance in medicine.

[5]  Thomas S. Huang,et al.  Image sequence analysis , 1981 .

[6]  J. Felmlee,et al.  Adaptive technique for high-definition MR imaging of moving structures. , 1989, Radiology.

[7]  Volker Rasche,et al.  Continuous radial data acquisition for dynamic MRI , 1995, Magnetic resonance in medicine.

[8]  Gerard de Haan,et al.  True-motion estimation with 3-D recursive search block matching , 1993, IEEE Trans. Circuits Syst. Video Technol..

[9]  M Hedley,et al.  Motion artifact correction in MRI using generalized projections. , 1991, IEEE transactions on medical imaging.

[10]  M. Bierling,et al.  Displacement Estimation By Hierarchical Blockmatching , 1988, Other Conferences.

[11]  S J Riederer,et al.  Compensation for effects of linear motion in MR imaging , 1989, Magnetic resonance in medicine.

[12]  M. L. Wood,et al.  MR image artifacts from periodic motion. , 1985, Medical physics.

[13]  T. S. Huang,et al.  Image Sequence Enhancement , 1981 .

[14]  R M Henkelman,et al.  Suppression of respiratory motion artifacts in magnetic resonance imaging. , 1986, Medical physics.

[15]  E M Haacke,et al.  Reducing motion artifacts in two-dimensional Fourier transform imaging. , 1986, Magnetic resonance imaging.

[16]  Yongmin Kim,et al.  Correction of computed tomography motion artifacts using pixel-specific back-projection , 1996, IEEE Trans. Medical Imaging.

[17]  A. G. Collins,et al.  Respiratory ordered phase encoding (ROPE): a method for reducing respiratory motion artefacts in MR imaging. , 1985, Journal of computer assisted tomography.

[18]  Berthold K. P. Horn,et al.  Determining Optical Flow , 1981, Other Conferences.