Abstract Microwave heating, because of its advantages of direct and rapid heating of materials, has the potential to be employed as a novel regeneration method of desiccant rotors in humidity conditioners. We proposed a combined regeneration process, which combines microwave heating and conventional hot-air heating. The system is expected to achieve high heating rate during an initial regeneration period by assisting water desorption using the additional energy of the microwave. In this study, the regeneration characteristics of a desiccant rotor were experimentally investigated under conditions of microwave heating, hot-air heating, and combined heating at various microwave powers and hot-air temperatures. The effectiveness of the combined regeneration was evaluated in terms of the regeneration ratio, the initial regeneration rate, the temperature distribution in the rotor, and finally in terms of the energy consumption. It was demonstrated that combined heating was effective at leveling non-uniform temperature distribution in the rotor. Combined heating achieved higher ratios and initial rates in regeneration compared to just microwave and hot-air heating. This result was obviously attributed to the additional input of microwave energy, resulting that average rotor temperature increased by microwave absorption of rotor. Moreover, it was also effective for enhancement of regeneration to level the temperature distribution in the rotor by combination of two heating methods with different heating mechanisms. Both the initial regeneration rate and the equilibrium regeneration ratio for combined heating were found to increase as the microwave power increased. A linear relationship was observed with respect to microwave power. From the viewpoint of energy consumption, it may be possible to apply combined and microwave heating to humidity control systems that switch between adsorption and regeneration in short cycle times, if the conversion and absorption efficiencies of the microwave are significantly improved.
[1]
Hitoki Matsuda,et al.
Water desorption behavior of desiccant rotor under microwave irradiation
,
2011
.
[2]
Akio Kodama.
Cross-Contamination Test of an Enthalpy Wheel Loading a Strong Acidic Cation Ion-Exchange Resin or 3A Zeolite as a Desiccant Material
,
2010
.
[3]
A. E. Kabeel,et al.
Solar powered air conditioning system using rotary honeycomb desiccant wheel
,
2007
.
[4]
A. Ledoux,et al.
Microwave Assisted Regeneration of Zeolite
,
2007
.
[5]
Marco Beccali,et al.
Energy and economic assessment of desiccant cooling systems coupled with single glazed air and hybrid PV/thermal solar collectors for applications in hot and humid climate
,
2009
.
[6]
T. Miyazaki,et al.
Performance analysis of air cycle refrigerator integrated desiccant system for cooling and dehumidifying warehouse
,
2008
.
[7]
Tianshu Ge,et al.
Experimental investigation on a one-rotor two-stage rotary desiccant cooling system
,
2008
.
[8]
J. Costa,et al.
Numerical study of the influence of the atmospheric pressure on the heat and mass transfer rates of desiccant wheels
,
2011
.