Taking a Closer Look--Continuous Glucose Monitoring in Non-Critically Ill Hospitalized Patients with Type 2 Diabetes Mellitus Under Basal-Bolus Insulin Therapy.

BACKGROUND Inpatient glucose management is based on four daily capillary blood glucose (BG) measurements. The aim was to test the capability of continuous glucose monitoring (CGM) for assessing the clinical impact and safety of basal-bolus insulin therapy in non-critically ill hospitalized patients with type 2 diabetes mellitus (T2DM). MATERIALS AND METHODS Eighty-four patients with T2DM (age, 68±10 years; glycosylated hemoglobin, 72±28 mmol/mol; body mass index, 31±7 kg/m(2)) were treated with basal-bolus insulin. CGM was performed with the iPro(®)2 system (Medtronic MiniMed, Northridge, CA) and calibrated retrospectively. RESULTS A remarkable consistency between CGM and BG measurements and therapy improvement was shown over the study period of 501 patient-days. The number of CGM and BG measurements (CGM/BG) in the range from 3.9-10 mmol/L increased from 67.7%/67.2% (on Day 1) to 77.5%/78.6% (on the last day) (P<0.04). The number of low glycemic episodes (3.3 to <3.9 mmol/L) during nighttime detected by CGM was 15-fold higher, and the number of episodes >13.9 mmol/L detected by CGM during night was 12.5-fold higher than the values from the BG measurements. Ninety-nine percent of data points were in the clinically accurate or acceptable Clarke Error Grid Zones A+B, and the relative numbers of correctly identified episodes of <3.9 and >13.9 mmol/L detected by CGM (sensitivity) were 47.3% and 81.5%, respectively. CONCLUSIONS Our data exhibit a good agreement between overall CGM and BG measurements, but there were a high number of missed hypo- and hyperglycemic episodes with BG measurements, particularly during nighttime. Overall assessment of glycemic control using CGM is feasible, whereas the use of CGM for individualized therapy decisions needs further improvement.

[1]  P. Binkley,et al.  Effect of the approach to insulin therapy on glycaemic fluctuations and autonomic tone in hospitalized patients with diabetes , 2013, Diabetes, obesity & metabolism.

[2]  C. Cook,et al.  Update on inpatient glycemic control in hospitals in the United States. , 2011, Endocrine practice : official journal of the American College of Endocrinology and the American Association of Clinical Endocrinologists.

[3]  B. Draznin,et al.  Pathways to Quality Inpatient Management of Hyperglycemia and Diabetes: A Call to Action , 2013, Diabetes Care.

[4]  Aesha Drozdowski,et al.  Standards of medical care in diabetes. , 2004, Diabetes care.

[5]  R Core Team,et al.  R: A language and environment for statistical computing. , 2014 .

[6]  Brian H Rowe,et al.  The relation between hyperglycemia and outcomes in 2,471 patients admitted to the hospital with community-acquired pneumonia. , 2005, Diabetes care.

[7]  A. M. Kyaw,et al.  Systematic review and meta-analysis of the effectiveness of continuous glucose monitoring (CGM) on glucose control in diabetes , 2013, Diabetology & Metabolic Syndrome.

[8]  David Rodbard,et al.  Interpretation of continuous glucose monitoring data: glycemic variability and quality of glycemic control. , 2009, Diabetes technology & therapeutics.

[9]  D. Cox,et al.  Evaluating Clinical Accuracy of Systems for Self-Monitoring of Blood Glucose , 1987, Diabetes Care.

[10]  A. Moran,et al.  Spurious reporting of nocturnal hypoglycemia by CGMS in patients with tightly controlled type 1 diabetes. , 2002, Diabetes care.

[11]  Limin Peng,et al.  Randomized Study Comparing a Basal-Bolus With a Basal Plus Correction Insulin Regimen for the Hospital Management of Medical and Surgical Patients With Type 2 Diabetes , 2013, Diabetes Care.

[12]  Inna Chervoneva,et al.  Clinical Need for Continuous Glucose Monitoring in the Hospital , 2009, Journal of diabetes science and technology.

[13]  D. Klonoff,et al.  Continuous glucose monitoring: an Endocrine Society Clinical Practice Guideline. , 2011, The Journal of clinical endocrinology and metabolism.

[14]  B. Kennon,et al.  Trends in recorded capillary blood glucose and hypoglycaemia in hospitalised patients with diabetes. , 2014, Diabetes research and clinical practice.

[15]  B. Draznin,et al.  Response to Comment on: Draznin et al. Pathways to Quality Inpatient Management of Hyperglycemia and Diabetes: A Call to Action. Diabetes Care 2013;36:1807–1814 , 2013, Diabetes Care.

[16]  J K Mader,et al.  Efficacy, usability and sequence of operations of a workflow‐integrated algorithm for basal–bolus insulin therapy in hospitalized type 2 diabetes patients , 2014, Diabetes, obesity & metabolism.

[17]  R. Beck,et al.  Use of continuous glucose monitoring as an outcome measure in clinical trials. , 2012, Diabetes technology & therapeutics.

[18]  Peter Calhoun,et al.  Performance comparison of the medtronic sof-sensor and enlite glucose sensors in inpatient studies of individuals with type 1 diabetes. , 2013, Diabetes technology & therapeutics.

[19]  J. Unger Uncovering undetected hypoglycemic events , 2012, Diabetes, metabolic syndrome and obesity : targets and therapy.

[20]  J. Callés-Escandon,et al.  Independently Associated With Length of Stay and Mortality in Non-Critically Ill Hospitalized Patients , 2013 .

[21]  L. Kennedy,et al.  Randomized Study of Basal-Bolus Insulin Therapy in the Inpatient Management of Patients With Type 2 Diabetes (RABBIT 2 Trial) , 2008 .

[22]  C. Cook,et al.  Assessing Inpatient Glycemic Control: What are the Next Steps? , 2012, Journal of diabetes science and technology.

[23]  Richard Hellman,et al.  American Association of Clinical Endocrinologists and American Diabetes Association consensus statement on inpatient glycemic control. , 2009, Endocrine practice : official journal of the American College of Endocrinology and the American Association of Clinical Endocrinologists.

[24]  Mary T Korytkowski,et al.  Management of hyperglycemia in hospitalized patients in non-critical care setting: an endocrine society clinical practice guideline. , 2012, The Journal of clinical endocrinology and metabolism.

[25]  J Hans DeVries,et al.  Insulin treatment guided by subcutaneous continuous glucose monitoring compared to frequent point-of-care measurement in critically ill patients: a randomized controlled trial , 2014, Critical Care.

[26]  R. Hovorka,et al.  Glucose control in non‐critically ill inpatients with diabetes: towards closed‐loop , 2014, Diabetes, obesity & metabolism.

[27]  D. Rodbard Standardization versus customization of glucose reporting. , 2013, Diabetes technology & therapeutics.

[28]  D. Klonoff,et al.  Recommendations for standardizing glucose reporting and analysis to optimize clinical decision making in diabetes: the Ambulatory Glucose Profile (AGP). , 2013, Diabetes technology & therapeutics.

[29]  L Heinemann,et al.  Continuous glucose monitoring: quality of hypoglycaemia detection , 2013, Diabetes, obesity & metabolism.

[30]  Mohammad Hassan Murad,et al.  Glycemic control in non-critically ill hospitalized patients: a systematic review and meta-analysis. , 2012, The Journal of clinical endocrinology and metabolism.

[31]  S. Inchiostro,et al.  How can we monitor glycaemic variability in the clinical setting? , 2013, Diabetes, obesity & metabolism.

[32]  G. Umpierrez,et al.  Continuous Glucose Monitoring in Insulin-Treated Patients in Non-ICU Settings , 2014, Journal of diabetes science and technology.