Frequency-domain identification of the respiratory system model during the interrupter experiment

Abstract This paper is the first in a series devoted to the metrological evaluation of the interrupter technique (IT). The aim of it is to propose effective modification of the classical algorithm and to summarize the research concentrated on evaluating the usefulness of the pressure and flow data frequency analysis on the estimation of the mechanical status of lungs. Based on the Frey et al. reports, a physical–mathematical representation of the respiratory system (modified DuBois’ model) was used. The electrical analog expresses the division of the physiological object into the tissue and airways segments. For such a theoretical structure, the optimal configuration of the measurement signals and the tools of their analysis have been simulated by means of forward–inverse modelling. At this stage, the possibility of expanding the inference on the system mechanics was shown. At the same time, the improvement of repeatability and evaluation precision in relation to the known IT realisation was observed.

[1]  M J Jaeger Effect of the cheeks and the compliance of alveolar gas on the measurement of respiratory variables. , 1982, Respiration physiology.

[2]  J Guttmann,et al.  Interrupter airway and tissue resistance: errors caused by valve properties and respiratory system compliance. , 1999, Journal of applied physiology.

[3]  B Suki,et al.  Human respiratory input impedance between 32 and 800 Hz, measured by interrupter technique and forced oscillations. , 1997, Journal of applied physiology.

[4]  R Kraemer,et al.  Pressure oscillations after flow interruption in relation to lung mechanics. , 1995, Respiration physiology.

[5]  J. Mead,et al.  Evaluation of airway interruption technique as a method for measuring pulmonary airflow resistance. , 1954, Journal of applied physiology.

[6]  E. Oostveen,et al.  The forced oscillation technique in clinical practice: methodology, recommendations and future developments , 2003, European Respiratory Journal.

[7]  K. Lutchen,et al.  Reliability of parameter estimates from models applied to respiratory impedance data. , 1987, Journal of applied physiology.

[8]  A M Collier,et al.  Respiratory impedance and derived parameters in young children by forced random noise. , 1979, Journal of applied physiology: respiratory, environmental and exercise physiology.

[9]  J. Bates,et al.  High-frequency characteristics of respiratory mechanics determined by flow interruption. , 1990, Journal of applied physiology.

[10]  R. Pimmel,et al.  Respiratory parameter estimation using forced oscillatory impedance data. , 1977, Journal of applied physiology: respiratory, environmental and exercise physiology.

[11]  Kenneth R. Lutchen,et al.  Relationship between frequency and amplitude dependence in the lung: a nonlinear block-structured modeling approach. , 1995, Journal of applied physiology.

[12]  S S Young,et al.  Frequency dependence of forced oscillatory respiratory mechanics in horses with heaves. , 1997, Journal of applied physiology.

[13]  K. Lutchen,et al.  Physiological interpretations based on lumped element models fit to respiratory impedance data: use of forward-inverse modeling , 1990, IEEE Transactions on Biomedical Engineering.

[14]  R Kraemer,et al.  Oscillatory pressure transients after flow interruption during bronchial challenge test in children. , 1997, The European respiratory journal.

[15]  A. Otis,et al.  Measurement of alveolar pressure in human subjects. , 1947, The American journal of physiology.

[16]  T. Similowski,et al.  Effect of negative expiratory pressure on respiratory system flow resistance in awake snorers and nonsnorers. , 1999, Journal of applied physiology.

[17]  B J Sobol A simple, rapid technique for assessing airway resistance during quiet breathing. , 1970, The American review of respiratory disease.

[18]  J. Bates,et al.  Measurement of alveolar pressure in closed-chest dogs during flow interruption. , 1989, Journal of applied physiology.

[19]  A. Jackson,et al.  A reevaluation of the interrupter technique for airway resistance measurement. , 1974, Journal of applied physiology.

[20]  Kenneth R. Lutchen,et al.  Statistical Measures of Parameter Estimates from Models Fit to Respiratory Impedance Data: Emphasis on Joint Vanabilities , 1986, IEEE Transactions on Biomedical Engineering.

[21]  Christopher B. Massa,et al.  Reliability of Estimating Stochastic Lung Tissue Heterogeneity from Pulmonary Impedance Spectra: A Forward-Inverse Modeling Study , 2007, Annals of Biomedical Engineering.

[22]  K.R. Lutchen,et al.  Confidence bounds on respiratory mechanical properties estimated from transfer versus input impedance in humans versus dogs , 1992, IEEE Transactions on Biomedical Engineering.

[23]  O Hochmuth,et al.  In vitro investigations of jet-pulses for the measurement of respiratory impedance in newborns. , 1999, The European respiratory journal.

[24]  H. Ghezzo,et al.  Role of inspiratory capacity on exercise tolerance in COPD patients with and without tidal expiratory flow limitation at rest. , 2000, The European respiratory journal.

[25]  Giuseppe Liistro,et al.  Reassessment of the interruption technique for measuring flow resistance in humans. , 1989, Journal of applied physiology.

[26]  A. W. Brody,et al.  Oscillation mechanics of lungs and chest in man. , 1956, Journal of applied physiology.

[27]  A T Johnson,et al.  Respiratory resistance measured by an airflow perturbation device. , 1999, Physiological measurement.

[28]  K. Lutchen,et al.  Inability to separate airway from tissue properties by use of human respiratory input impedance. , 1990, Journal of applied physiology.

[29]  K. Lutchen,et al.  Inverse modeling of dog airway and respiratory system impedances. , 1987, Journal of applied physiology.