Ability of modal analysis to detect osseointegration of implants in transfemoral amputees: a physical model study
暂无分享,去创建一个
Nicola J. Cairns | Mark J. Pearcy | James Smeathers | Clayton Adam | M. Pearcy | J. Smeathers | C. Adam | N. Cairns
[1] Deborah Caine,et al. Back to the Basics , 2021, Interceram - International Ceramic Review.
[2] Kenneth G. McConnell,et al. Modal testing , 2001, Philosophical Transactions of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences.
[3] Martin Groten,et al. Resonance frequency analysis and damping capacity assessment. Part I: an in vitro study on measurement reliability and a method of comparison in the determination of primary dental implant stability. , 2006, Clinical oral implants research.
[4] L Sennerby,et al. Resonance frequency measurements of implant stability in vivo. A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla. , 1997, Clinical oral implants research.
[5] L. A. Taber,et al. Vibrational characteristics of the embalmed human femur , 1981 .
[7] P. Avitabile. Modal Space: Back to Basics , 2002 .
[8] Shu Chien,et al. The Osseointegration Book: From Calvarium to Calcaneus , 2005 .
[9] N Meredith,et al. Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis. , 1996, Clinical oral implants research.
[10] G. Blunn,et al. Development Of An Intraosseous Transcutaneous Amputation Prostheses (ITAP) , 2011 .
[11] J. Sullivan,et al. Rehabilitation of the transfemoral amputee with an osseointegrated prosthesis: The United Kingdom experience , 2003, Prosthetics and orthotics international.
[12] K. Hagberg,et al. One hundred patients treated with osseointegrated transfemoral amputation prostheses--rehabilitation perspective. , 2009, Journal of rehabilitation research and development.
[13] José A. Simões,et al. Experimental modal analysis of a synthetic composite femur , 2004 .
[14] R. Blevins,et al. Formulas for natural frequency and mode shape , 1984 .
[15] Kent N Bachus,et al. Percutaneous osseointegrated prostheses for amputees: Limb compensation in a 12-month ovine model. , 2011, Journal of biomechanics.
[16] G. Tomassini,et al. Atlas of amputations and limb deficiencies: Surgical, prosthetic, and rehabilitation principles , 2005 .
[17] R.L. Mayes,et al. Part 4: What’s shakin’, dude? effective use of modal shakers , 2006 .
[18] F. Shao,et al. Natural Frequency Analysis of Osseointegration for Trans-femoral Implant , 2007, Annals of Biomedical Engineering.
[20] Clayton J. Adam,et al. Evaluation of modal analysis techniques using physical models to detect osseointegration of implants in transfemoral amputees , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.
[21] A. Clausen,et al. Die Endo-Exo-Femurprothese – ein neues Konzept zur knochengeführten, prothetischen Versorgung von oberschenkelamputierten Patienten , 2009 .
[22] Martin Groten,et al. Resonance frequency analysis and damping capacity assessment. Part 2: peri-implant bone loss follow-up. An in vitro study with the Periotest and Osstell instruments. , 2006, Clinical oral implants research.
[23] Robert Jones,et al. Quantitative Determination of the Stability of Implant-Bone Interface Using Resonance Frequency Analysis , 2002 .
[24] Smith Dg,et al. Atlas of Amputations and Limb Deficiencies, Third Edition: Surgical, Prosthetic and Rehabilitation Principles , 2004 .
[25] David L Cochran,et al. Resonance frequency measurement of implant stability in vivo on implants with a sandblasted and acid-etched surface. , 2003, The International journal of oral & maxillofacial implants.
[26] K. Ou,et al. Design of a stability-detecting device for dental implants , 2005, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.
[27] Smith Dg,et al. Atlas Of Amputations and Limb Deficiencies : Surgical, Prosthetic, and Rehabilitation Principles , 2004 .
[28] K. Hagberg,et al. Osseointegrated trans-femoral amputation prostheses: Prospective results of general and condition-specific quality of life in 18 patients at 2-year follow-up , 2008, Prosthetics and orthotics international.
[29] A Bezerianos,et al. Monitoring of fracture healing by lateral and axial vibration analysis. , 1990, Journal of biomechanics.
[30] Mark David Muller,et al. Transfemoral Amputation : Prosthetic Management , 2022 .
[31] J B Brunski,et al. A dynamic modal testing technique for noninvasive assessment of bone-dental implant interfaces. , 1996, The International journal of oral & maxillofacial implants.
[32] Nicola J. Cairns,et al. The feasibility of vibration analysis as a technique to detect osseointegration of transfemoral implants , 2010 .