A wearable heart monitor at the ear using ballistocardiogram (BCG) and electrocardiogram (ECG) with a nanowatt ECG heartbeat detection circuit

This work presents a wearable heart monitor at the ear that uses the ballistocardiogram (BCG) and the electrocardiogram (ECG) to extract heart rate, stroke volume, and pre-ejection period (PEP) for the application of continuous heart monitoring. Being a natural anchoring point, the ear is demonstrated as a viable location for the integrated sensing of physiological signals. The source of periodic head movements is identified as a type of BCG, which is measured using an accelerometer. The head BCG's principal peaks (J-waves) are synchronized to heartbeats. Ensemble averaging is used to obtain consistent J-wave amplitudes, which are related to stroke volume. The ECG is sensed locally near the ear using a single-lead configuration. When the BCG and the ECG are used together, an electromechanical duration called the RJ interval can be obtained. Because both head BCG and ECG have low signal-to-noise ratios, cross-correlation is used to statistically extract the RJ interval. The ear-worn device is wirelessly connected to a computer for real time data recording. A clinical test involving hemodynamic maneuvers is performed on 13 subjects. The results demonstrate a linear relationship between the J-wave amplitude and stroke volume, and a linear relationship between the RJ interval and PEP. While the clinical device uses commercial components, a custom integrated circuit for ECG heartbeat detection is designed with the goal of reducing power consumption and device size. With 58nW of power consumption, the ECG circuit replaces the traditional instrumentation amplifier, analog-to-digital converter, and signal processor with a single chip solution. The circuit demonstrates a topology that takes advantage of the ECG's characteristics to extract R-wave timings at the chest and the ear in the presence of baseline drift, muscle artifact, and signal clipping.

[1]  V. V. Ermishkin,et al.  Beat-by-beat changes in pre-ejection period during functional tests evaluated by impedance aortography: a step to a left ventricular contractility monitoring , 2007 .

[2]  Xavier Neyt,et al.  Three dimensional ballistocardiography: Methodology and results from microgravity and dry immersion , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[3]  A. Weissler,et al.  Systolic Time Intervals in Heart Failure in Man , 1968, Circulation.

[4]  Gregory T. A. Kovacs,et al.  Ballistocardiography — A method worth revisiting , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[5]  Emery N. Brown,et al.  Motion and Ballistocardiogram Artifact Removal for Interleaved Recording of EEG and EPs during MRI , 2002, NeuroImage.

[6]  J. V. van Lieshout,et al.  Non‐invasive pulsatile arterial pressure and stroke volume changes from the human finger , 2005, Experimental physiology.

[7]  Refet Firat Yazicioglu,et al.  A Configurable and Low-Power Mixed Signal SoC for Portable ECG Monitoring Applications , 2011, IEEE Transactions on Biomedical Circuits and Systems.

[8]  G. Kovacs,et al.  Non-invasive assessment of cardiac contractility on a weighing scale , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[9]  P. Vries,et al.  The technique of impedance cardiography. , 1997, European heart journal.

[10]  Gregory T. A. Kovacs,et al.  Non-invasive measurement of Valsalva-induced hemodynamic changes on a bathroom scale Ballistocardiograph , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[11]  D. Gibson,et al.  Mechanisms of prolongation of pre-ejection period in patients with left ventricular disease. , 1979, British heart journal.

[12]  Omer T. Inan,et al.  Recent advances in cardiovascular monitoring using ballistocardiography , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[13]  Francis Eng Hock Tay,et al.  A Long-term Wearable Vital Signs Monitoring System using BSN , 2008, 2008 11th EUROMICRO Conference on Digital System Design Architectures, Methods and Tools.

[14]  W. J. Elliott,et al.  Novel Approach to Examining First Cardiovascular Events After Hypertension OnsetLloyd-Jones DM, Leip EP, Larson MG, et al (Northwestern Univ, Chicago; NIH, Framingham, Mass) Hypertension 45:39-45, 2005§ , 2006 .

[15]  G. Srivastava,et al.  ICA-based procedures for removing ballistocardiogram artifacts from EEG data acquired in the MRI scanner , 2005, NeuroImage.

[16]  S. Kaplan,et al.  Measurement of Right and Left Ventricular Systolic Time Intervals by Echocardiography , 1975, Circulation.

[17]  Guanqun Zhang,et al.  Pulse arrival time is not an adequate surrogate for pulse transit time as a marker of blood pressure. , 2011, Journal of applied physiology.

[18]  A. Waller A Demonstration of Man of Electromotive Changes Accompanying the Heart's Beat , 2004, The Journal of physiology.

[19]  O. Postolache,et al.  Vital Signs Monitoring System Based on EMFi Sensors and Wavelet Analysis , 2007, 2007 IEEE Instrumentation & Measurement Technology Conference IMTC 2007.

[20]  G. Schillaci,et al.  Circadian blood pressure changes and left ventricular hypertrophy in essential hypertension. , 1990, Circulation.

[21]  H MANDELBAUM,et al.  Studies Utilizing the Portable Electromagnetic Ballistocardiograph: IV. The Clinical Significance of Serial Ballistocardiograms Following Acute Myocardial Infarction , 1953, Circulation.

[22]  Yutaka Imai,et al.  Prognosis of "masked" hypertension and "white-coat" hypertension detected by 24-h ambulatory blood pressure monitoring 10-year follow-up from the Ohasama study. , 2005, Journal of the American College of Cardiology.

[23]  R. Payne,et al.  Pulse transit time measured from the ECG: an unreliable marker of beat-to-beat blood pressure. , 2006, Journal of applied physiology.

[24]  Steffen Leonhardt,et al.  Adaptive Beat-to-Beat Heart Rate Estimation in Ballistocardiograms , 2011, IEEE Transactions on Information Technology in Biomedicine.

[25]  W.M.C. Sansen,et al.  A micropower low-noise monolithic instrumentation amplifier for medical purposes , 1987 .

[26]  W. Fye,et al.  A history of the origin, evolution, and impact of electrocardiography. , 1994, The American journal of cardiology.

[27]  I. Starr,et al.  STUDIES ON THE ESTIMATION OF CARDIAC OUPTUT IN MAN, AND OF ABNORMALITIES IN CARDIAC FUNCTION, FROM THE HEART'S RECOIL AND THE BLOOD'S IMPACTS; THE BALLISTOCARDIOGRAM , 1939 .

[28]  Yan Chen,et al.  A new methodology of continuous and noninvasive blood pressure measurement by pulse wave velocity , 2010, 2010 11th International Conference on Control Automation Robotics & Vision.

[29]  H. Dodge,et al.  The Relationship of Alterations in Systolic Time Intervals to Ejection Fraction in Patients with Cardiac Disease , 1970, Circulation.

[30]  Refet Firat Yazicioglu,et al.  A 30µW Analog Signal Processor ASIC for biomedical signal monitoring , 2010, 2010 IEEE International Solid-State Circuits Conference - (ISSCC).

[31]  Daehwa Paik,et al.  A low-noise self-calibrating dynamic comparator for high-speed ADCs , 2008, 2008 IEEE Asian Solid-State Circuits Conference.

[32]  Kwang Suk Park,et al.  Non-constrained monitoring of systolic blood pressure on a weighing scale , 2009, Physiological measurement.

[33]  David A. Johns,et al.  Analog Integrated Circuit Design , 1996 .

[34]  M. B. Rappaport,et al.  Ballistocardiography: I. Physical Considerations , 1953, Circulation.

[35]  D. Korteweg Ueber die Fortpflanzungsgeschwindigkeit des Schalles in elastischen Rhren , 1878 .

[36]  Denis C. Daly,et al.  A 6-bit, 0.2 V to 0.9 V Highly Digital Flash ADC With Comparator Redundancy , 2009, IEEE Journal of Solid-State Circuits.

[37]  Devin B. McCombie,et al.  Motion based adaptive calibration of pulse transit time measurements to arterial blood pressure for an autonomous, wearable blood pressure monitor , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[38]  M. Roizen Forecasting the Future of Cardiovascular Disease in the United States: A Policy Statement From the American Heart Association , 2012 .

[39]  Naveen Verma,et al.  A Micro-Power EEG Acquisition SoC With Integrated Feature Extraction Processor for a Chronic Seizure Detection System , 2010, IEEE Journal of Solid-State Circuits.

[40]  Gregory T. A. Kovacs,et al.  Multi-signal electromechanical cardiovascular monitoring on a modified home bathroom scale , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[41]  Luis Afonso,et al.  Global and Regional Left Ventricular Contractile Impairment in Patients with Wolff-Parkinson-White Syndrome , 2009, Indian pacing and electrophysiology journal.

[42]  Scott K. Arfin,et al.  Fast startup CMOS current references , 2006, 2006 IEEE International Symposium on Circuits and Systems.

[43]  X. Aubert,et al.  Cuffless Estimation of Systolic Blood Pressure for Short Effort Bicycle Tests: The Prominent Role of the Pre-Ejection Period , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[44]  Alpo Värri,et al.  The potential of EMFi sensors in heart activity monitoring , 2004 .

[45]  Johan E P Waktare Cardiology patient page. Atrial fibrillation. , 2002, Circulation.

[46]  Choi Jin-Wook,et al.  A New Method for Unconstrained Pulse Arrival Time (PAT) Measurement on a Chair , 2006 .

[47]  L. Geddes,et al.  Measurements of Young's Modulus of Elasticity of the Canine Aorta with Ultrasound , 1979 .

[48]  A. Varri,et al.  A new method for measuring the ballistocardiogram using EMFi sensors in a normal chair , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[49]  Francesco Rizzo,et al.  24h seismocardiogram monitoring in ambulant subjects , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[50]  Kwang Suk Park,et al.  Wakefulness estimation only using ballistocardiogram: Nonintrusive method for sleep monitoring , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.

[51]  J.M. Padilla,et al.  Assessment of relationships between blood pressure, pulse wave velocity and digital volume pulse , 2006, 2006 Computers in Cardiology.

[52]  Yan Chen,et al.  Continuous and Noninvasive Blood Pressure Measurement: A Novel Modeling Methodology of the Relationship Between Blood Pressure and Pulse Wave Velocity , 2009, Annals of Biomedical Engineering.

[53]  Richard M. Wiard,et al.  Robust ballistocardiogram acquisition for home monitoring , 2009, Physiological measurement.

[54]  Y.T. Zhang,et al.  The effects of pre-ejection period on the blood pressure estimation using pulse transit time , 2008, 2008 5th International Summer School and Symposium on Medical Devices and Biosensors.

[55]  Giovanni Calcagnini,et al.  On the resolution of ECG acquisition systems for the reliable analysis of the P-wave , 2012, Physiological measurement.

[56]  A. Weissler,et al.  Left Ventricular Systolic Time Intervals as Indices of Postural Circulatory Stress in Man , 1970, Circulation.

[57]  I. Starr,et al.  Twenty‐Year Studies with the Ballistocardiograph: The Relation between the Amplitude of the First Record of "Healthy" Adults and Eventual Mortality and Morbidity from Heart Disease , 1961 .

[58]  R. R. Harrison,et al.  A low-power low-noise CMOS amplifier for neural recording applications , 2003, IEEE J. Solid State Circuits.

[59]  Kazuki Iwata,et al.  Artifact reduction for EEG/fMRI recording: Nonlinear reductionof ballistocardiogram artifacts , 2006, Clinical Neurophysiology.

[60]  Carmen C. Y. Poon,et al.  Cuff-less and Noninvasive Measurements of Arterial Blood Pressure by Pulse Transit Time , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[61]  Stuart N. Wooters,et al.  A 2.6-µW sub-threshold mixed-signal ECG SoC , 2009, 2009 Symposium on VLSI Circuits.

[62]  C. Yancy,et al.  Noninvasive hemodynamic monitoring in heart failure: utilization of impedance cardiography. , 2003, Congestive heart failure.