In vitro and in vivo evaluation of albumin synthesis rate of porcine hepatocytes in a flat-plate bioreactor.

Several configurations of extracorporeal bioartificial liver devices have been developed for the potential treatment of fulminant hepatic failure or as a bridge to liver transplantation. Recently, we developed a microchannel flat-plate bioreactor with an internal membrane oxygenator in which porcine hepatocytes are cultured as a monolayer on the bottom glass surface. In the present study, we investigated synthetic function of porcine hepatocytes in the bioreactor in both in vitro and in vivo flow circuit models. In vitro, albumin synthesis was stable in the bioreactor for up to 4 days of perfusion. In vivo, with the extracorporeal connection of the bioreactor to rat vasculature, porcine albumin was detectable for 24 h in the rat plasma. We also developed a simple mathematical model to predict the in vivo porcine albumin concentration in rat plasma. These results indicate that this configuration of a microchannel flat-plate bioreactor has potential as a liver support device and warrants further investigation.

[1]  M. Toner,et al.  Effects of oxygenation and flow on the viability and function of rat hepatocytes cocultured in a microchannel flat-plate bioreactor. , 2001, Biotechnology and bioengineering.

[2]  S. Bhatia,et al.  Xenobiotic metabolism by cultured primary porcine hepatocytes. , 2000, Tissue engineering.

[3]  M. Toner,et al.  In Vitro Characterization of Porcine Hepatocyte Function , 2000, Cell transplantation.

[4]  M. Toner,et al.  Effect of extracellular matrix topology on cell structure, function, and physiological responsiveness: hepatocytes cultured in a sandwich configuration , 1996, FASEB journal : official publication of the Federation of American Societies for Experimental Biology.

[5]  R. Tompkins,et al.  Extracorporeal plasma perfusion of cultured hepatocytes: effect of intermittent perfusion on hepatocyte function and morphology. , 1996, The Journal of surgical research.

[6]  H. Fukuda,et al.  Long-term performance of albumin secretion of hepatocytes cultured in a packed-bed reactor utilizing porous resin. , 1996, Artificial organs.

[7]  D. Samuel,et al.  Orthotopic Liver Transplantation in Fulminant and Subfulminant Hepatitis The Paul Brousse Experience , 1995, Annals of surgery.

[8]  J. Lemasters,et al.  Evidence that activation of Kupffer cells increases oxygen uptake after cold storage. , 1994, Transplantation.

[9]  J. Encke,et al.  Bioreactor for a larger scale hepatocyte in vitro perfusion. , 1994, Transplantation.

[10]  S. Nyberg,et al.  Extracorporeal Application of a Gel-Entrapment, Bioartificial Liver: Demonstration of Drug Metabolism and Other Biochemical Functions , 1993, Cell transplantation.

[11]  A. Guillouzo,et al.  Correction of Bilirubin Conjugation in the Gunn Rat Using Hepatocytes Immobilized in Alginate Gel Beads as an Extracorporeal Bioartificial Liver , 1993, Cell transplantation.

[12]  R. Tompkins,et al.  Hepatic Tissue Engineering: Development of Critical Technologies , 1992, Annals of the New York Academy of Sciences.

[13]  N. Sussman,et al.  Reversal of fulminant hepatic failure using an extracorporeal liver assist device , 1992, Hepatology.

[14]  R. Tompkins,et al.  Long‐Term in Vitro Function of Adult Hepatocytes in a Collagen Sandwich Configuration , 1991, Biotechnology progress.

[15]  W. Arnaout,et al.  Development of bioartificial liver: bilirubin conjugation in Gunn rats. , 1990, The Journal of surgical research.

[16]  J. S. Carvalho Heterologous serum albumin as tracer for plasma volume measurements evaluated in conscious nondehydrated and 48-hour water-deprived rats. , 1989, Journal of Cardiovascular Pharmacology.

[17]  A. Bader,et al.  A Novel Full‐Scale Flat Membrane Bioreactor Utilizing Porcine Hepatocytes: Cell Viability and Tissue‐Specific Functions , 2000, Biotechnology progress.

[18]  M L Yarmush,et al.  Oxygen consumption characteristics of porcine hepatocytes. , 1999, Metabolic engineering.