Numerical simulations of unsteady flows in a stenosed coronary bypass graft

Using the finite element method, physiological blood flows through a three-dimensional model of a coronary graft are numerically analysed. The model includes a stenosis shape in the host artery upstream from the anastomosis. Recirculating areas, secondary flows, wall shear stress (WSS) and spatial wall shear stress gradients (WSSGs) are studied for different flow repartitions and at different times in the cycle. The temporal and spatial evolutions of the recirculating areas downstream from the stenosis, their interactions with the flow issued from the graft and their associated WSSs highlight that the presence of the stenosis in the recipient artery is essential for prediction of the evolution of a grafting at the beginning of its implantation. The areas downstream from the stenosis expansion, non-existent for a host artery without stenosis, are submitted to low and oscillating WSS between −0.5 and 0 Nm−2. The stagnation point on the recipient artery floor is subjected to high positive and negative WSSGnd values, and its location is dependent on the residual flow through the stenosis.

[1]  T. O'donnell,et al.  Pulsatile flow and atherosclerosis in the human carotid bifurcation: Positive correlation between plaque location and low and oscillating shear stress: Ku DN, Giddens DP, Zarins CK, et al. Arteriosclerosis 1985; 5: 293–302 , 1986 .

[2]  R. Nerem Vascular fluid mechanics, the arterial wall, and atherosclerosis. , 1992, Journal of biomechanical engineering.

[3]  C. R. Ethier,et al.  Steady and pulsatile flow fields in an end-to-side arterial anastomosis model. , 1990, Journal of vascular surgery.

[4]  R. Pélissier,et al.  Experimental analysis of unsteady flows through a stenosis. , 1997, Journal of biomechanics.

[5]  B. Rubin,et al.  Candida infection with aneurysm formation in the juxtarenal aorta. , 1994, Journal of Vascular Surgery.

[6]  C. R. Ethier,et al.  Flow waveform effects on end-to-side anastomotic flow patterns. , 1998, Journal of biomechanics.

[7]  W. Quist,et al.  Flow disturbance at the distal end-to-side anastomosis. Effect of patency of the proximal outflow segment and angle of anastomosis. , 1980, Archives of surgery.

[8]  J D Thomas,et al.  The effect of angle and flow rate upon hemodynamics in distal vascular graft anastomoses: a numerical model study. , 1991, Journal of biomechanical engineering.

[9]  D. Ku,et al.  Pulsatile velocity measurements in a model of the human abdominal aorta under resting conditions. , 1994, Journal of biomechanical engineering.

[10]  S. Raghunathan,et al.  Numerical Simulations of Time‐Dependent, non‐Newtonian Blood Flow through Typical Human Arterial Bypass Grafts , 2008 .

[11]  V Deplano,et al.  Experimental and numerical study of pulsatile flows through stenosis: wall shear stress analysis. , 1999, Journal of biomechanics.

[12]  R. Keynton,et al.  The effect of angle and flow rate upon hemodynamics in distal vascular graft anastomoses: an in vitro model study. , 1991, Journal of biomechanical engineering.

[13]  C Kleinstreuer,et al.  Numerical investigation and prediction of atherogenic sites in branching arteries. , 1995, Journal of biomechanical engineering.

[14]  Christine Bertolotti Modèles numérique et expérimental des écoulements dans les pontages coronaires , 1999 .

[15]  C Kleinstreuer,et al.  Hemodynamics analyses of arterial expansions with implications to thrombosis and restenosis. , 2000, Medical engineering & physics.

[16]  C Bertolotti,et al.  Three-dimensional numerical simulations of flow through a stenosed coronary bypass. , 2000, Journal of biomechanics.

[17]  S Glagov,et al.  Hemodynamic patterns in two models of end-to-side vascular graft anastomoses: effects of pulsatility, flow division, Reynolds number, and hood length. , 1993, Journal of biomechanical engineering.

[18]  A. Chorin Numerical Solution of the Navier-Stokes Equations* , 1989 .

[19]  F. S. Henry,et al.  Numerical investigation of steady flow in proximal and distal end-to-side anastomoses. , 1996, Journal of biomechanical engineering.

[20]  Z Lou,et al.  Biofluid dynamics at arterial bifurcations. , 1992, Critical reviews in biomedical engineering.

[21]  V. Fuster,et al.  Influence of Arterial Damage and Wall Shear Rate on Platelet Deposition: Ex Vivo Study in a Swine Model , 1986, Arteriosclerosis.

[22]  A. Beaudoin,et al.  Analysis of shear stress and hemodynamic factors in a model of coronary artery stenosis and thrombosis. , 1993, The American journal of physiology.

[23]  J. Moake,et al.  THE RESPONSE OF HUMAN PLATELETS TO SHEAR STRESS AT SHORT EXPOSURE TIMES , 1977, Transactions - American Society for Artificial Internal Organs.

[24]  C Kleinstreuer,et al.  Relation between non-uniform hemodynamics and sites of altered permeability and lesion growth at the rabbit aorto-celiac junction. , 1999, Atherosclerosis.

[25]  G Pennati,et al.  Numerical analysis of steady flow in aorto-coronary bypass 3-D model. , 1996, Journal of biomechanical engineering.

[26]  J. W. White The Effect of Two-Dimensional Surface Roughness on the Load-Carrying Capacity of a Thin Compressible Gas Film , 1993 .

[27]  M. Eriksen Effect of pulsatile arterial diameter variations on blood flow estimated by Doppler ultrasound , 2006, Medical and Biological Engineering and Computing.