Evaluation of the thermal performance indices of a ventilated double window through experimental and analytical procedures: Uw-values

Simulations to evaluate energy demand for heating and cooling and thermal comfort are becoming more and more common place in the building design process, at least in the most complex cases. In all detailed or simplified calculations, to analyse heat transfer to and from a building, several input parameters are needed. The inputs for the simulation of a whole building are at least the building geometry, the building envelope thermal indices (like thermal transmittance or the solar heat gain coefficient) and typical local climatic data. In a ventilated double window, the air flow through the channel between the two windows makes its thermal performance highly dynamic and dependent on the air flow characteristics. For a whole building simulation, single coefficients or easily calculated coefficients are needed for each facade system, including ventilated systems. In this paper, equivalent thermal transmittance coefficients for a ventilated double window are assessed and presented. For that, experimental measurements in the absence of solar radiation (night period) were used to identify tendencies and validate calculations. Furthermore, simulations were done in order to estimate the Uw-values of the ventilated double window under different windows configuration and different air flow rates. These values can then be used in whole building simulation programmes.

[1]  D. Naylor,et al.  A CFD study of convection in a double glazed window with an enclosed pleated blind , 2009 .

[2]  Robert Hastings,et al.  Solar Air Systems - A Design Handbook , 2000 .

[3]  K. Ismail,et al.  Two-dimensional model for the double glass naturally ventilated window , 2005 .

[4]  P. Baker,et al.  Test cell analysis of the use of a supply air window as a passive solar component , 2000 .

[5]  Jorge S. Carlos,et al.  Real climate experimental study of two double window systems with preheating of ventilation air , 2010 .

[6]  Simos Yannas,et al.  Solar Energy and Housing Design , 1994 .

[7]  Chang Heon Cheong,et al.  Lifecycle CO2 Reduction by Implementing Double Window Casement Systems in Residential Units in Korea , 2015 .

[8]  Joseph Virgone,et al.  Development and validation of regression models to predict monthly heating demand for residential buildings , 2008 .

[9]  Toke Rammer Nielsen,et al.  Simple tool to evaluate energy demand and indoor environment in the early stages of building design , 2005 .

[10]  Jorge S. Carlos,et al.  Modelling and simulation of a ventilated double window , 2011 .

[11]  A. Oliva,et al.  Numerical analysis of the thermal behaviour of ventilated glazed facades in Mediterranean climates. Part I: development and validation of a numerical model , 2003 .

[12]  A. Oliva,et al.  Numerical analysis of the thermal behaviour of glazed ventilated facades in Mediterranean climates. Part II: applications and analysis of results , 2003 .

[13]  Iso Tc,et al.  Thermal Performance of Windows, Doors and Shading Devices — Detailed Calculations , 2000 .

[14]  Kim Bjarne Wittchen,et al.  Calculation of building heating demand in EPIQR , 2000 .

[15]  M. Sivrioglu,et al.  An experimental study on air window collector having a vertical blind for active solar heating , 1996 .

[16]  P. H. Baker,et al.  Test cell evaluation of supply air windows to characterise their optimum performance and its verification by the use of modelling techniques , 2003 .

[17]  Hui Zhang,et al.  Window performance for human thermal comfort , 2006 .