Optimization of operating parameters in a hybrid wind–hydrogen system using energy and exergy analysis: Modeling and case study

Abstract In this study, hybrid renewable energy system based on wind/electrolyzer/PEM fuel cell are conceptually modeled, and also, exergy and energy analysis are performed. The energy and exergy flows are investigated by the proposed model for Khaf region-Iran with high average wind speed and monsoon. Exergy and energy analysis framework is made based on thermodynamic, electro-chemical and mechanical model of the different component of hybrid system. Also, the effects of various operating parameters in exergy efficiency are calculated. The results show an optimum wind speed where the exergy efficiency and power coefficient is at maximum level, and also, when the ambient temperature start to be increased in wind turbine, the efficiencies decrease by a great deal for constant wind speeds. Also, the optimum temperature is calculated by exergy analysis in electrolyzer and fuel cell as 353 and the exergy efficiency of electrolyzer decreases by increasing the membrane thickness. Furthermore, pressure changes affect exergy and energy efficiency in PEM fuel cell. Finally, the electrolyzer and fuel cell efficiencies are calculated as 68.5% and 47% respectively.

[1]  S. Chan,et al.  Polarization effects in electrolyte/electrode-supported solid oxide fuel cells , 2002 .

[2]  Ch. Haberstroh,et al.  Exergy and cost analyses of hydrogen-based energy storage pathways for residual load management , 2015 .

[3]  James Larminie,et al.  Fuel Cell Systems Explained , 2000 .

[4]  Kodjo Agbossou,et al.  Control analysis of renewable energy system with hydrogen storage for residential applications , 2006 .

[5]  A. J. Calderón,et al.  Evaluation of a hybrid photovoltaic-wind system with hydrogen storage performance using exergy analy , 2011 .

[6]  Eamon McKeogh,et al.  Simulation and operational assessment for a small autonomous wind–hydrogen energy system , 2006 .

[7]  Paola Costamagna,et al.  Quantum jumps in the PEMFC science and technology from the 1960s to the year 2000 ☆: Part II. Engineering, technology development and application aspects , 2001 .

[8]  M. Rosen,et al.  Exergy analysis of hydrogen production from heat and water by electrolysis , 1992 .

[9]  J. Andrews,et al.  Dimensionless analysis of the global techno-economic feasibility of solar-hydrogen systems for constant year-round power supply , 2012 .

[10]  Joseph J. Romm,et al.  The Hype About Hydrogen: Fact and Fiction in the Race to Save the Climate , 2004 .

[11]  Onder Ozgener,et al.  Exergy and reliability analysis of wind turbine systems: A case study , 2007 .

[12]  D. Leung,et al.  Energy and exergy analysis of hydrogen production by a proton exchange membrane (PEM) electrolyzer plant , 2008 .

[13]  Ø. Ulleberg,et al.  The wind/hydrogen demonstration system at Utsira in Norway: Evaluation of system performance using operational data and updated hydrogen energy system modeling tools , 2010 .

[14]  M. Melaina Initiating hydrogen infrastructures: preliminary analysis of a sufficient number of initial hydrogen stations in the US , 2003 .

[15]  James F. Manwell,et al.  Book Review: Wind Energy Explained: Theory, Design and Application , 2006 .

[16]  Ryan Wiser,et al.  Understanding wind turbine price trends in the U.S. over the past decade , 2012 .

[17]  Ibrahim Dincer,et al.  Exergy: Energy, Environment and Sustainable Development , 2007 .

[18]  K. Agbossou,et al.  Renewable energy systems based on hydrogen for remote applications , 2001 .

[19]  Emmanuel Kasseris,et al.  Optimization of a wind-power fuel-cell hybrid system in an autonomous electrical network environment , 2007 .

[20]  Ibrahim Dincer,et al.  Energy, exergy and exergoeconomic analyses of a combined renewable energy system for residential applications , 2014 .

[21]  Orhan Aydin,et al.  Wind energy–hydrogen storage hybrid power generation , 2001 .

[22]  S. S. Penner,et al.  Steps toward the hydrogen economy , 2006 .

[23]  Mark C. Williams,et al.  U.S. distributed generation fuel cell program , 2004 .

[24]  K. Yasuda,et al.  Thin film electrocatalyst layer for unitized regenerative polymer electrolyte fuel cells , 2002 .

[25]  A. Kazim Exergy analysis of a PEM fuel cell at variable operating conditions , 2004 .

[26]  B. K. Keshavan,et al.  Analysis of seasonal wind speed and wind power density distribution in Aimangala wind form at Chitradurga Karnataka using two parameter weibull distribution function , 2011, 2011 IEEE Power and Energy Society General Meeting.

[27]  T. Nejat Veziroglu,et al.  21st Century's Energy: Hydrogen Energy System , 2008 .

[28]  Ayoub Kazim,et al.  Effects of cathode operating conditions on performance of a PEM fuel cell with interdigitated flow fields , 2003 .

[29]  R. Datta,et al.  PEM fuel cell as a membrane reactor , 2001 .

[30]  D. Stolten,et al.  Ten years of operational experience with a hydrogen-based renewable energy supply system , 2003 .

[31]  Frano Barbir,et al.  An Analytical Solution of a Half‐Cell Model for PEM Fuel Cells , 2000 .

[32]  Ali Mohammad Ranjbar,et al.  Fuzzy modeling techniques and artificial neural networks to estimate annual energy output of a wind turbine , 2010 .

[33]  H. Nfaoui,et al.  Modelling of a wind/diesel system with battery storage for Tangiers, Morocco , 1994 .

[34]  Christopher J. Koroneos,et al.  Exergy analysis in a wind speed prognostic model as a wind farm sitting selection tool: A case study in Southern Greece , 2009 .

[35]  Pierre Millet,et al.  Design and performance of a solid polymer electrolyte water electrolyzer , 1996 .

[36]  M. J. Moran,et al.  Thermal design and optimization , 1995 .

[37]  Sabah A. Abdul-Wahab,et al.  Weather data and analysis of hybrid photovoltaic-wind power generation systems adapted to a seawater greenhouse desalination unit designed for arid coastal countries. , 2008 .

[38]  Leyla Ozgener,et al.  Exergoeconomic assessment of a wind turbine power plant (WTTP): Cesme, Izmir, example , 2012 .

[39]  Ramin Roshandel,et al.  Performance of a standalone wind-hydrogen power system for regions with seasonal wind profile: A case study in Khaf region , 2014 .

[40]  Zhou Wei,et al.  Optimal design and techno-economic analysis of a hybrid solar–wind power generation system , 2009 .

[41]  Majid Amidpour,et al.  Techno-economic analysis of wind turbine–PEM (polymer electrolyte membrane) fuel cell hybrid system in standalone area , 2014 .

[42]  Mohammad S. Alam,et al.  Dynamic modeling, design and simulation of a wind/fuel cell/ultra-capacitor-based hybrid power generation system , 2006 .

[43]  Christopher J. Koroneos,et al.  Maximization of wind energy penetration with the use of H2 production—An exergy approach , 2011 .

[44]  P. Seferlis,et al.  Power management strategies for a stand-alone power system using renewable energy sources and hydrogen storage , 2009 .

[45]  Surya Santoso,et al.  Fundamental time–domain wind turbine models for wind power studies , 2007 .

[46]  Shin'ya Obara,et al.  Exergy analysis of a regional-distributed PEM fuel cell system , 2008 .