RF Current Density Imaging in Homogeneous Media

MRI has proven capable of imaging quasistatic volume current densities in electrolytic and biological media. In this paper, the feasibility of extending the method to image RF current density at the Larmor frequency is studied. RF current imaging could be relevant to MR power absorption and safety and to hyperthermia analysis, as well as creating dielectric and conductivity‐dependent tissue contrast. The approach is to deliberately induce or inject RF currents in a sample synchronous with an MR pulse sequence and measure the resulting transverse RF magnetic field components. Current density is extracted by computing the curl of the magnetic fields. The preliminary theory has been developed for uniform media where both displacement and conduction currents exist while skin effects or eddy currents are absent. If the derivative in the BO direction of the RF magnetic field component parallel to BO is negligible, then sufficient information exists to reconstruct the RF current density component that is parallel to BO without rotating the sample. The relative phase of the current can also be estimated. The method has been proven feasible by successfully imaging a uniform 85.6‐MHz current density in a salt water phantom. The experiment conforms closely to capacitively coupled hyperthermia heating.© 1992 Academic Press,Inc.

[1]  D. Paris,et al.  Basic Electromagnetic Theory , 1969 .

[2]  L. Segel,et al.  Mathematics Applied to Continuum Mechanics , 1977 .

[3]  G. Nussbaum Physical aspects of hyperthermia , 1982 .

[4]  A. Konrad,et al.  Three‐dimensional finite element solution of anisotropic complex potential problems , 1982 .

[5]  Keith D. Paulsen,et al.  Finite element solution of Maxwell's equations for hyperthermia treatment planning , 1985 .

[6]  K. S. Arun,et al.  Least-Squares Fitting of Two 3-D Point Sets , 1987, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[7]  S. Müller,et al.  Multifrequency selective rf pulses for multislice MR imaging , 1988, Magnetic resonance in medicine.

[8]  M. Joy,et al.  In vivo detection of applied electric currents by magnetic resonance imaging. , 1989, Magnetic resonance imaging.

[9]  Greig C. Scott,et al.  Two-dimensional current density imaging , 1990 .

[10]  Joachim Seelig,et al.  Numerical analysis of multislice mr excitation and inversion with multifrequency selective rf pulses , 1990, Magnetic resonance in medicine.

[11]  Charles T. M. Choi,et al.  Finite element modeling of the RF heating process , 1991 .

[12]  R M Henkelman,et al.  Measurement of nonuniform current density by magnetic resonance. , 1991, IEEE transactions on medical imaging.

[13]  Johan Philip Estimation Three-Dimensional Motion of Rigid Objects from Noisy Observations , 1991, IEEE Trans. Pattern Anal. Mach. Intell..

[14]  R. Henkelman,et al.  Sensitivity of magnetic-resonance current-density imaging , 1992 .