Column temperature programming in enantioseparation of dihydropyrimidinone compounds using derivatized cellulose and amylose chiral stationary phases.

We report the application of column temperature programs as a tool to examine unusual temperature-induced behaviors of polysaccharide chiral stationary phases (CSPs). Using dihydropyrimidinone (DHP) compounds as probes we observed the heating (10-50 degrees C) and cooling (50-10 degrees C) van't Hoff plots of retention factors and/or selectivities of DHP compounds were not superimposable on AD, IA, and AS-H columns solvated with ethanol (EtOH)/n-hexane (n-Hex) mobile phases. The plots were not superimposable on AD, IB, and AS-H columns solvated with 2-propanol (2-PrOH)/n-Hex mobile phases. The thermally induced path-dependant behaviors were caused by slow equilibration as evidenced by the disappearance of the hysteresis in the second heating to cooling cycle and in a cooling to heating cycle. From the step-temperature program (10-50-10 degrees C), only EtOH solvated AD and AS-H phases showed the change of retention factors and/or selectivities with time while only 2-PrOH solvated AS-H phase showed similar behaviors.

[1]  Wenjian Lao,et al.  Responses of enantioselective characteristics of imidazolinone herbicides and Chiralcel OJ column to temperature variations. , 2006, Journal of chromatography. A.

[2]  C. White Integration of supercritical fluid chromatography into drug discovery as a routine support tool. Part I. fast chiral screening and purification. , 2005, Journal of chromatography. A.

[3]  F. Wang,et al.  Comparison study of Chiralpak AD-H with AD columns in chromatographic enantioseparation of dihydropyrimidinone acid and its methyl ester. , 2004, Journal of chromatography. A.

[4]  Tao Wang,et al.  Effects of alcohol mobile-phase modifiers on the structure and chiral selectivity of amylose tris(3,5-dimethylphenylcarbamate) chiral stationary phase. , 2003, Journal of chromatography. A.

[5]  K. Mueller,et al.  Characterization of a thermally induced irreversible conformational transition of amylose tris(3,5-dimethylphenylcarbamate) chiral stationary phase in enantioseparation of dihydropyrimidinone acid by quasi-equilibrated liquid chromatography and solid-state NMR. , 2003, Analytical chemistry.

[6]  C. White,et al.  Impact of normal-phase gradient elution in chiral chromatography: a novel, robust, efficient and rapid chiral screening procedure. , 2003, Journal of chromatography. A.

[7]  F. Wang,et al.  Unusual effect of column temperature on chromatographic enantioseparation of dihydropyrimidinone acid and methyl ester on amylose chiral stationary phase. , 2002, Journal of chromatography. A.

[8]  T. Wang,et al.  Solid-state NMR characterization of amylose tris(3,5-dimethylphenylcarbamate) chiral stationary-phase structure as a function of mobile-phase composition. , 2001, Analytical chemistry.

[9]  Yadan W. Chen,et al.  Enantiomeric separation of some pharmaceutical intermediates and reversal of elution orders by high-performance liquid chromatography using cellulose and amylose tris(3,5-dimethylphenylcarbamate) derivatives as stationary phases. , 2000, Journal of chromatography. A.

[10]  Masato Kazusaki,et al.  INFLUENCE OF TEMPERATURE ON ENANTIOSEPARATION EMPLOYING AN AMYLOSE-DERIVATIVE STATIONARY PHASE , 2000 .

[11]  T. Wang,et al.  Application and comparison of derivatized cellulose and amylose chiral stationary phases for the separation of enantiomers of pharmaceutical compounds by high-performance liquid chromatography. , 1999, Journal of chromatography. A.

[12]  E. Yashima,et al.  Polysaccharide Derivatives for Chromatographic Separation of Enantiomers. , 1998, Angewandte Chemie.

[13]  T. O'brien,et al.  Mechanistic aspects of chiral discrimination on modified cellulose. , 1997, Analytical chemistry.

[14]  P. Murray,et al.  An instance of temperature-dependent elution order of enantiomers from a chiral brush-type HPLC column , 1993 .

[15]  J. Dorsey,et al.  Temperature dependence of retention in reversed-phase liquid chromatography. 1. Stationary-phase considerations. , 1992, Analytical chemistry.

[16]  W. H. Pirkle Unusual effect of temperature on the retention of enantiomers on a chiral column , 1991 .

[17]  E. Papadopoulou-mourkidou Effect of column temperature on the direct determination of (RS)-.alpha.-cyano(3-phenoxyphenyl)methyl (RS)-2-(4-chlorophenyl)-3-methylbutyrate optical isomers by high-performance liquid chromatography/diode array system , 1989 .

[18]  J. Harris,et al.  Temperature-Induced Changes in Reversed-Phase Chromatographic Surfaces: C8 and C9 Polymeric Ligands , 1989 .

[19]  R. K. Gilpin,et al.  Reordering/resolvation of silica immobilized hydrogen bonding ligands used as stationary phases in high-performance liquid chromatography , 1987 .

[20]  R. K. Gilpin,et al.  Effect of Temperature on the Orientation of Bonded Hydrocarbon Phases in Totally Aqueous Liquid Chromatographic Systems , 1981 .