A comparative analysis of shunt active power filter and hybrid active power filter with different control techniques applied for harmonic elimination in a single phase system

This paper presents a comparative analysis between a single phase shunt active power filter (SPSAPF) and a single phase shunt hybrid filter (SPSHPF) to improve the power quality using different control techniques such as hysteresis current control and hysteresis fuzzy combined current control technique along with a different fuzzy rule (7/7 and 5/5) to a distribution system. An indirect current control technique along with hysteresis current control strategy is implemented on both the filters to generate the switching signal used for turning on and off of the insulated gate bipolar transistor. The indirect current control technique that is implemented for both filters is based on extracting the source current reference from the distorted waveform of the load current. The Simulink models are prepared. Simulation results are obtained and compared for both the filters with the same control technique, and it is observed that in every case SPSHPF shows excellent results in comparison to SPSAPF.

[1]  M.P. Kazmierkowski,et al.  Review of current regulation techniques for three-phase PWM inverters , 1994, Proceedings of IECON'94 - 20th Annual Conference of IEEE Industrial Electronics.

[2]  P. Karuppanan,et al.  A novel adaptive-fuzzy hysteresis current controller-based active power line conditioners for power quality enhancement , 2013 .

[3]  K. Derradji Belloum,et al.  A Fixed Band Hysteresis Current Controller for Voltage Source AC Chopper , 2008 .

[4]  E.R. Cadaval,et al.  Comparison of Control Strategies for Shunt Active Power Filters in Three-Phase Four-Wire Systems , 2007, IEEE Transactions on Power Electronics.

[5]  Kamal Al-Haddad,et al.  A review of active filters for power quality improvement , 1999, IEEE Trans. Ind. Electron..

[6]  F. Mekri,et al.  Fuzzy Hysteresis Control and Parameter Optimization of a Shunt Active Power Filter , 2005, J. Inf. Sci. Eng..

[7]  Valentin G. Ivanov,et al.  Alterable fuzzy sets in automotive control applications , 2008, Int. J. Model. Identif. Control..

[8]  Marco Liserre,et al.  Optimal tuning of a fuzzy logic-based single-phase active power filter via the Nelder-Mead method , 2006, Int. J. Comput. Appl. Technol..

[9]  J. S. Subjak,et al.  Harmonics-causes, effects, measurements and analysis-update , 1989, IEEE Record of Conference Papers on Cement Industry Technical Conference.

[10]  Hirofumi Akagi,et al.  The unified power quality conditioner: the integration of series- and shunt-active filters , 1998 .

[11]  Murat Kale,et al.  An adaptive hysteresis band current controller for shunt active power filter , 2005 .

[12]  Hadi Youssef Kanaan,et al.  A comparative study of shunt hybrid and shunt active power filters for single-phase applications: Simulation and experimental validation , 2006, Math. Comput. Simul..

[13]  P Karuppanan,et al.  Fuzzy Logic Controlled Active Power Line Conditioners for Power quality Improvements , 2010 .

[14]  Hirofumi Akagi,et al.  New trends in active filters for power conditioning , 1996 .

[15]  W. M. Grady,et al.  Survey of active power line conditioning methodologies , 1990 .

[16]  P.L. So,et al.  Improvement of power quality using adaptive shunt active filter , 2005, IEEE Transactions on Power Delivery.

[17]  N. Selvaganesan,et al.  Design and implementation of fuzzy logic controller for high performance coupled inductor DC-DC converter , 2008 .

[18]  C.K. Duffey,et al.  Update of harmonic standard IEEE-519-IEEE Recommended Practices and Requirements for Harmonic Control in Electric Power Systems , 1989, Conference Record of the IEEE Industry Applications Society Annual Meeting,.

[19]  Ahmed Alaa Elkousy,et al.  Performance comparison of shunt active power filter for interval type-2 fuzzy and adaptive backstepping controllers , 2014, Int. J. Model. Identif. Control..

[20]  Zhiwei Wen,et al.  A novel detection method and compensation strategy based on PQR transformation for PCC voltage of wind power system , 2013, Int. J. Model. Identif. Control..

[21]  D. Devaraj,et al.  Fuzzy Logic – Based Approach for Adaptive Hysteresis Band and Dc Voltage Control in Shunt Active Filter , 2010 .

[22]  Defeng Wu,et al.  A comparative study on the active power filter control strategy for independent and small power system , 2013, Int. J. Model. Identif. Control..