Frequency domain registration of computer tomography data

This work presents a new method for registering computer tomography (CT) volumetric data of human bone structures relative to observations made at different times. The system we advance was tested with different kinds of CT data sets. We report on some representative experimental results obtained with the CT data of the hip bones of a patient prior to and after prosthetic surgery aimed at the reconstruction of the hip articulation. The method works with rigid data having arbitrary relative position and orientation and proves to be robust with respect to CT acquisition noise and with respect to the segmentation technique adopted to select the region of interest for registration. The method is capable of registering correctly data sets taken from the same articulation and whose components have undergone small relative displacements. The method is also amenable to registration of heteregeneous kinds of volumetric data, e.g., CT scans and magnetic resonance imagery (MRI) scans, which show different characteristics in correspondence to the same organic structure.

[1]  Daniel Rueckert,et al.  Nonrigid registration using free-form deformations: application to breast MR images , 1999, IEEE Transactions on Medical Imaging.

[2]  Nicholas Ayache,et al.  Medical Image Analysis: Progress over Two Decades and the Challenges Ahead , 2000, IEEE Trans. Pattern Anal. Mach. Intell..

[3]  Richard M. Murray,et al.  A Mathematical Introduction to Robotic Manipulation , 1994 .

[4]  Heinz Hügli,et al.  A multi-resolution scheme ICP algorithm for fast shape registration , 2002, Proceedings. First International Symposium on 3D Data Processing Visualization and Transmission.

[5]  Jayaram K. Udupa,et al.  Incorporating a measure of local scale in voxel-based 3-D image registration , 2003, IEEE Transactions on Medical Imaging.

[6]  Zhengyou Zhang,et al.  Iterative point matching for registration of free-form curves and surfaces , 1994, International Journal of Computer Vision.

[7]  Marc Levoy,et al.  Efficient variants of the ICP algorithm , 2001, Proceedings Third International Conference on 3-D Digital Imaging and Modeling.

[8]  Kari Pulli,et al.  Multiview registration for large data sets , 1999, Second International Conference on 3-D Digital Imaging and Modeling (Cat. No.PR00062).

[9]  Margrit Betke,et al.  Automatic 3D Registration of Lung Surfaces in Computed Tomography Scans , 2001, MICCAI.

[10]  D. Rubens,et al.  Three-dimensional registration and fusion of ultrasound and MRI using major vessels as fiducial markers , 2001, IEEE Transactions on Medical Imaging.

[11]  Jonathan S. Lewin,et al.  Slice-to-volume registration and its potential application to interventional MRI-guided radio-frequency thermal ablation of prostate cancer , 2003, IEEE Transactions on Medical Imaging.

[12]  Ioannis Pitas,et al.  Morphological Iterative Closest Point Algorithm , 1997, CAIP.