Continuous analysis of dye-loaded, single cells on a microfluidic chip.

Continuous analysis of two dyes loaded into single mammalian cells using laser-based lysis combined with electrophoretic separation was developed and characterized on microfluidic chips. The devices employed hydrodynamic flow to transport cells to a junction where they were mechanically lysed by a laser-generated cavitation bubble. An electric field then attracted the analyte into a separation channel while the membranous remnants passed through the intersection towards a waste reservoir. Phosphatidylcholine (PC)-supported bilayer membrane coatings (SBMs) provided a weakly negatively charged surface and prevented cell fouling from interfering with device performance. Cell lysis using a picosecond-pulsed laser on-chip did not interfere with concurrent electrophoretic separations. The effect of device parameters on performance was evaluated. A ratio of 2 : 1 was found to be optimal for the focusing-channel : flow-channel width and 3 : 1 for the flow-channel : separation-channel width. Migration times decreased with increased electric field strengths up to 333 V cm(-1), at which point the field strength was sufficient to move unlysed cells and cellular debris into the electrophoretic channel. The migration time and full width half-maximum (FWHM) of the peaks were independent of cell velocity for velocities between 0.03 and 0.3 mm s(-1). Separation performance was independent of the exact lysis location when lysis was performed near the outlet of the focusing channel. The migration time for cell-derived fluorescein and fluorescein carboxylate was reproducible with <10% RSD. Automated cell detection and lysis were required to reduce peak FWHM variability to 30% RSD. A maximum throughput of 30 cells min(-1) was achieved. Device stability was demonstrated by analyzing 600 single cells over a 2 h time span.

[1]  Vasan Venugopalan,et al.  Characterization and use of laser-based lysis for cell analysis on-chip , 2008, Journal of The Royal Society Interface.

[2]  E. Yeung,et al.  Determination of intracellular species at the level of a single erythrocyte via capillary electrophoresis with direct and indirect fluorescence detection. , 1992, Analytical chemistry.

[3]  K. Jensen,et al.  Cells on chips , 2006, Nature.

[4]  Mark Bachman,et al.  Fast electrical lysis of cells for capillary electrophoresis. , 2003, Analytical chemistry.

[5]  N. Allbritton,et al.  Separations in poly(dimethylsiloxane) microchips coated with supported bilayer membranes. , 2008, Analytical Chemistry.

[6]  N. Allbritton,et al.  Chemical analysis of single cells. , 2008, Annual review of analytical chemistry.

[7]  Quan Cheng,et al.  Microfluidic immunoassay for bacterial toxins with supported phospholipid bilayer membranes on poly(dimethylsiloxane). , 2005, Analytical chemistry.

[8]  J. Jorgenson,et al.  Capillary zone electrophoresis. , 1983, Science.

[9]  M W Berns,et al.  Laser-micropipet combination for single-cell analysis. , 1998, Analytical chemistry.

[10]  C. Lucy,et al.  Phospholipid bilayer coatings for the separation of proteins in capillary electrophoresis. , 2002, Analytical chemistry.

[11]  Alexandra Ros,et al.  Improved native UV laser induced fluorescence detection for single cell analysis in poly(dimethylsiloxane) microfluidic devices. , 2006, Journal of chromatography. A.

[12]  N. Allbritton,et al.  Measurement of kinase activation in single mammalian cells , 2000, Nature Biotechnology.

[13]  Bo Huang,et al.  Counting Low-Copy Number Proteins in a Single Cell , 2007, Science.

[14]  Matthew Tirrell,et al.  Cell adhesion and growth to Peptide-patterned supported lipid membranes. , 2007, Langmuir : the ACS journal of surfaces and colloids.

[15]  Q. Cheng,et al.  Stable and fluid ethylphosphocholine membranes in a poly(dimethylsiloxane) microsensor for toxin detection in flooded waters. , 2005, Analytical chemistry.

[16]  A. Manz,et al.  Micro total analysis systems. Latest advancements and trends. , 2006, Analytical chemistry.

[17]  Alexandra Ros,et al.  Single cell manipulation, analytics, and label‐free protein detection in microfluidic devices for systems nanobiology , 2005, Electrophoresis.

[18]  N. Allbritton,et al.  Air-stable supported membranes for single-cell cytometry on PDMS microchips. , 2010, Lab on a chip.

[19]  A. Ewing,et al.  Capillary zone electrophoresis with electrochemical detection in 12.7 microns diameter columns. , 1988, Analytical chemistry.

[20]  Xue-feng Yin,et al.  Novel multi-depth microfluidic chip for single cell analysis. , 2006, Journal of chromatography. A.

[21]  M. McClain,et al.  Microfluidic devices for the high-throughput chemical analysis of cells. , 2003, Analytical chemistry.

[22]  Emily H Turner,et al.  Chemical cytometry: fluorescence-based single-cell analysis. , 2008, Annual review of analytical chemistry.

[23]  Vasan Venugopalan,et al.  Examination of laser microbeam cell lysis in a PDMS microfluidic channel using time-resolved imaging. , 2008, Lab on a chip.

[24]  J. Jorgenson,et al.  Microcolumn separations and the analysis of single cells. , 1989, Science.

[25]  Nancy L Allbritton,et al.  CRITICAL REVIEW www.rsc.org/loc | Lab on a Chip Analysis of single mammalian cells on-chip , 2006 .

[26]  C. Culbertson,et al.  Single cell analysis on microfluidic devices. , 2006, Methods in molecular biology.

[27]  P. N. Rao,et al.  Clinical Resistance to STI-571 Cancer Therapy Caused by BCR-ABL Gene Mutation or Amplification , 2001, Science.

[28]  M. Malmsten Protein adsorption at phospholipid surfaces , 1995 .

[29]  R. Zare,et al.  Chemical cytometry on a picoliter-scale integrated microfluidic chip. , 2004, Proceedings of the National Academy of Sciences of the United States of America.

[30]  Chang Lu,et al.  Microfluidic chemical cytometry based on modulation of local field strength. , 2006, Chemical communications.

[31]  Karel Klepárník,et al.  Detection of DNA fragmentation in a single apoptotic cardiomyocyte by electrophoresis on a microfluidic device , 2003, Electrophoresis.

[32]  Paul S. Cremer,et al.  Solid supported lipid bilayers: From biophysical studies to sensor design , 2006, Surface Science Reports.

[33]  Gregory T. Roman,et al.  Single-cell manipulation and analysis using microfluidic devices , 2006, Analytical and bioanalytical chemistry.

[34]  Zhao-Lun Fang,et al.  Integration of single cell injection, cell lysis, separation and detection of intracellular constituents on a microfluidic chip. , 2004, Lab on a chip.